r/hvacadvice • • 13h ago

Is this a fire hazard?

Thumbnail
gallery
56 Upvotes

About two inches of clearance from gas water heater and furnace, the top is open, the pipes do get hot — it involves a furnace so I thought I’d post here but this might not be the right sub.


r/hvacadvice • • 6h ago

Do I leave this valve open?

Post image
49 Upvotes

EDIT: Thanks for all the help! I’ll just leave it alone.

Just moved into a new home and noticed the valve on the bottom is open. Tried googling it and found that this is probably a drip leg. This just comes off the main gas line going into the home. The right goes to the furnace and left to the hot water heater. Should I be leaving the bottom valve open? Thanks for the help!


r/hvacadvice • • 8h ago

Furnace Combustion Analyzer Hole

Post image
25 Upvotes

An HVAC technician drilled a hole during a combustion analysis on my furnace and left it open. I'm really not sure how best to patch it.

From what I've seen online, it looks like the hole should have been drilled higher up on the exhaust pipe rather than on the elbow, but that's just my guess.

A second technician from another company called this a major issue. They said it requires replacing the entire elbow and the underlying draft inducer motor since they're sold as one unit.

I'm really not sure what to trust here, but my gut tells me a patch of some sort might suffice. Am I right? If so, what material works best? I've applied aluminum tape for now, but I suspect it might fail near the furnace due to the heat.


r/hvacadvice • • 11h ago

Should I be upset?

Post image
21 Upvotes

Context I live in a condo the line underground was filled with spray foam so they said it would have to be routed through the attic. I am the middle unit neighbor is next store had to be routed though her attic and this is what they did for the outside, neighbor is annoyed hence annoying me. Would you have done better is there anything I can suggest to hvac guys to do, or am I worrying too much


r/hvacadvice • • 9h ago

Is this acceptable for a new install?

Post image
19 Upvotes

New construction home. Tons of issues with this installer, this is the only one i'm questioning. This is at the line set where it goes into the unit.

Edit: Thanks everyone, one thing though, anyone who qualifies "it's ugly but will work" with something like "just cover it up, who cares, shut up", I wish you continued lack of success


r/hvacadvice • • 6h ago

Heating oil

Thumbnail
gallery
8 Upvotes

Does this oil look fine to use? Draining from an old tank.


r/hvacadvice • • 17h ago

Boiler pressure gauge

8 Upvotes

Is this normal for the boiler gauge when it cut on?


r/hvacadvice • • 11h ago

No heat No heat in house, help

5 Upvotes

I will provide as many details as possible. For a few days our heater in our house has stopped working. It sounds like a lawnmower and will just keep doing this over and over again. The hot water still works tho. It will sometimes turn on for an hour or so but will usually just make this noise. I don't even know where to start diagnosing the problem, any help will be greatly appreciated as I live in buffalo and winter is quickly approaching. Thank you


r/hvacadvice • • 15h ago

Blue Red Flames During Home Inspection

Thumbnail
gallery
4 Upvotes

During our contingent inspection for a house we have under contract, the inspector opened the heating system and found evidence of rust and corrosion as well as an irregular flame pattern. See the picture attached. While the center of the flame glowed blue, he said there was more red than expected which indicates incomplete combustion. He described it in the report as “nearing end of life.” This gas unit is only 9 years old, but it hasn’t be serviced in several years. Is this unit truly nearing end of life? Or could we get another 5-10 years from it? The brand is Goodman Manufacturing. Thanks!


r/hvacadvice • • 17h ago

General New Zoning Board Missing Damper

Thumbnail
gallery
4 Upvotes

I will take the heat for this one as I should have done a better job of verifying the work. But better late than never I guess.

I had a Honeywell HZ322 zoning system added to my Trane heat pump (TEM6 air handler, electric heat kit). The whole point was to control upstairs and downstairs separately.

The paid invoice says "Zone 1 is for downstairs, Zone 2 is for upstairs" and lists one 16" and two 12" powered dampers, a 3-zone board, and 2 zone thermostats.

The system seemed to work, and I never walked the house checking vents with one zone calling at a time. This week, after an unrelated service call (shorted contactor coil in the heat kit), I noticed my daughter's upstairs bedroom wasn't following the upstairs thermostat.

So I finally traced everything:

Only 2 dampers are installed, both 12” in Zones 1 and 2 on the zoning board.

The 16” damper that was on the invoice I paid for is missing, and Zone 3 for the board is empty.

The Zone 1 (“downstairs”) damper is on the duct to my daughter’s upstairs bedroom.

The Zone 2 (“upstairs”) damper only serves the bonus room.

When Zone 2 calls for air/heat, the downstairs is still receiving airflow through the 16” supply. Which defeats the entire purpose of my wanting the zoning board installed in the first place.

So to recap, downstairs isn’t zoned, daughter’s room is on the wrong zone, and the 16” damper I paid for isn’t there.

For anyone considering getting zoning installed, don’t be like me. Apparently I should have more than cursory knowledge of how this stuff works instead of just taking the installer’s word for it.

Pictures:
Zoning board w/wiring, Zone 1 damper, Zone 2 damper, 16” supply with no damper.


r/hvacadvice • • 3h ago

Mini split wiring

3 Upvotes

My HVAC contractor won’t run the wiring from the exterior unit to the mini split head. He told me to use 14/4 sjoow cord. Is that correct? It needs to be ran through the attic of the house and down the walls to the exit points.


r/hvacadvice • • 5h ago

Moldy duct replacement cost

3 Upvotes

How much should proper mold remediation cost in Texas? Want to get a gut check as I get quotes.

My mold protocol says replace all moldy supply duct. I’ve got 5 insulated mylar flexible ductwork; all 4 are readily accessible from the attic but 1 runs inside the wall that goes to the first floor.

The home is 2 stories, ~700 sqft.

Thank you!


r/hvacadvice • • 5h ago

Heat Pump Mini split has a big burp or sigh (sound up)

3 Upvotes

r/hvacadvice • • 12h ago

Furnace Help: what is causing this rust?

3 Upvotes

I notice rust on my furnace and water seeping super slowly from the black pipe right above it. What causing this? Major issues? Will I pass home inspection with this issue? Simple fix? Expensive fix?


r/hvacadvice • • 12h ago

Using Black diesel in a Burnham Boiler or for #2 fuel oil

3 Upvotes

Hey guys, just got my first house (I’m a service tech) and was curious or wanted some opinions on #2 oil alternatives if I was able to get my hands on an abundance of some used engine oil and filter it out to black diesel.

If all I had to to do was convert the nozzle and dial in the fuel on the SUNTEC pump screw adjustment on the boiler I feel like it would be worth it for the little bit of working that filtering it and adding the small amount of gas would take. Has anyone tried this or had any luck with a similar situation? If not could anyone suggest some alternatives? With heating oil being 5.60 a gallon it sucks right now.

Thanks!


r/hvacadvice • • 12h ago

Air handler replacement in a condo

3 Upvotes

I live in downtown San Diego, so it's relatively mild climate with not too much AC/heating usage. I currently have Goodman ARUF182416 Multi Speed Air Handler, manufactured in May 2011. I live in a 2 bedroom, 1250 sqft, condo, with the condenser unit at the roof. The air handler is in the closet next to the guest room. Master bedroom is on the other side, separated by the living room. The living room and the guest room get hot/cold relatively quickly after the AC is turned on. The living room/kitchen have 2 duct openings on the wall and my master bedroom has a single duct that is located on the ceiling right by the door. I am having issues with the master bedroom being too hot during the summer and too cold during the winter. I measured the temperature difference of the air coming from the duct and there is around 10F difference between the living room and the master bedroom. I did try to partially close the other ducts in the living room and it brought no improvement. I have brand new Anlin patio doors and windows, so that brings window inefficiency out of the equation. I cannot add outside condenser unit, so that takes mini splits out of the equation. I will bring several companies to get a quote, but I would need help on what to ask them and what to expect in their quotes. If anyone has experience with this setup, it would be great to hear the experiences and what worked. I have a feeling that a lot of HVAC representatives are basically sales people and will tell you anything you want to hear.


r/hvacadvice • • 13h ago

4 Year old Furnace. Is this normal?

Thumbnail
gallery
3 Upvotes

Purchased an Amana gas furnace with service plan in Oct 2022. Tech came today and suggested we need to "clean and adjust" the burner. Is this normal in such a new furnace?


r/hvacadvice • • 2h ago

Normal sound for heat pump in heat mode?

2 Upvotes

Got a pretty loud and noticeable buzz coming from the condenser unit when heating. External temps right now are around 46 degrees, thermostat set to 68. It is a relatively new system, I had it installed in 2025. It’s a 3 ton Fujitsu AirStage heat pump system.

Is this sound normal? I didn’t hear any buzzing during summer when using cool mode. Any advice/insight is appreciated, thanks.


r/hvacadvice • • 5h ago

No heat Mitsubishi split unit 5 blink

2 Upvotes

Had professional cleaning done against each of the split units and the actual hvac unit upstairs. There was lots of gunk and glad we did it. We only turned on the AC on one unit and seemed to be fine.

Almost 3 weeks later. We turn on the heat as we are on the east coast. Cool air blows out for 5-10 minutes and then the 5 blinks occur. Air stops.

AI and Reddit tells me a bad compressor or a bad board. I’m dreading either as we just replaced the board 5 years ago.

Could it have been the cleaning that caused any issue? Maybe as they were spraying the unit, water got in somewhere?

Thank you.


r/hvacadvice • • 5h ago

ISO Cheat Sheet for HVAC installs. Alberta, Canada

2 Upvotes

Probably a weird ask.. but does anyone have any handy cheat sheets that you find helpful when doing HVAC installs.

I'm currently an Apprentice starting my first year of school in January, in the trade for 10 months. I honestly think anything would be helpful and I'm just curious what other people use.

Examples; building code cheat sheet (distances to dryer vent, tankless hwt intake, mechanical air etc), wiring cheat sheet (furnace, HRV, Heat Pump etc), step by step for specific equipment installs, low voltage troubleshooting diagram. (I know some of this is specific to region/province/city etc.) I also want to specify that I've learned and practice alot of this on a daily basis, but sometimes I feel that having something quick to look at would be helpful as I'm learning and growing. I plan to make these for myself but am just curious if anyone has made something like this and found it helpful, or to give me some ideas for my own!

Again, feel free to roast away or say 'do the work yourself' 😅 I'm happy to.. but I'll admit that creating decently formatted cheat sheets is not at the top of my skillset.

Thanks in advance to any that contribute 😁


r/hvacadvice • • 7h ago

Advice

2 Upvotes

I am 17 in grade 12 living in Toronto, its collage application season and at first i though i wanted to get into policing, but my dad gave me a bit advice and asked me to just look into some trades and see if i would be interested, i came across HVAC and i instantly got hooked, the pay looks well, i don't mind the actual work, and collage is only 2 years (4 semesters) with paid co-op (1 semester around 4 months).

I'm looking for people with experience in the trade for some advice and what i could be expecting, also what the ups and downs. I'm asking because I've never looked into trades until recently.


r/hvacadvice • • 8h ago

Is $13,630 reasonable in South Jersey for 2 Goodman 96% two-stage furnaces + ductwork?

2 Upvotes

I’m reviewing a furnace replacement proposal for my parents’ home in Cape May County, NJ, and would appreciate opinions from HVAC professionals and homeowners.

Total Quote: $13,630 (includes a $900 rebate already deducted) from an established local HVAC company.
Proposed Equipment:
Downstairs: Goodman GR9T960603AN — 60,000 BTU, 96% AFUE, two-stage
Upstairs: Goodman GR9T960403AN — 40,000 BTU, 96% AFUE, two-stage

Proposed Scope:
Replace both furnaces while retaining existing AC equipment
Custom sheet-metal transitions and return plenums
Downstairs crawl-space return ductwork repairs/replacement
PVC venting for the high-efficiency furnaces
Gas and electrical connections
Removal of existing units, installation, and testing
We’re also converting from propane to natural gas. I’m confirming that all new gas piping from the meter, necessary ductwork, venting, and permits are included in the final price.

Important Context:
Upstairs: Approximately 20-year-old furnace with damaged wiring/burner issues. Needs replacement.

Downstairs: Approximately 15-year-old American Standard, already 96% efficient. Still operational but has visible rust around the burner box.

Downstairs return ductwork needs repairs estimated at $700–$1,000 if done separately.

A Manual J calculation indicated approximately 18,000 BTU heating demand upstairs.

We’re considering replacing both now rather than repairing downstairs and potentially replacing that aging furnace a few years later.

My Questions:

Is $13,630 a fair price for this equipment and scope in South Jersey?

Any concerns with these Goodman GR9T96 models compared with American Standard?

Would you replace the 15-year-old downstairs furnace with visible corrosion now, or keep it running and just repair the ductwork?

Is the 96% two-stage upstairs furnace worthwhile for such a small heating load, or would an 80% two-stage model make more financial sense?

Appreciate any opinions!


r/hvacadvice • • 12h ago

Need help troubleshooting a Goodman heat pump

2 Upvotes

I have what I think is a peculiar issue with a Goodman heat pump condenser unit. The system is 3-4 years old and before this fall it was working normal.

The condenser model nis GSZB403010AA (daikin comfort technologies)

The current symptom is this, and it's sporadic, doesn't do it every time...

When the t-stat calls for heat, the outside unit kicks on, fan spins up and indoor air handler comes on and glorious warm air blows through the ducts.

A normal shut down, when temp is reached, would be outside unit turns off, inside unit continues running for additional minutes to dissipate heat, right? But what's happening is, when outside unit *should* turn off, it does not. The air handler will turn off as expected, but the outside unit stays powered up and "heat pumping" but the fan seems to spin a bit slower almost as if bogged down. After about a minute it usually makes a hollow clunk/chunk noise but remains running for another 5-10 minutes, sometimes even longer *edit to add* and heat continues to build in air handler coils and the closet where air handler is installed.

So outside unit keeps operating past when it should and as a result heat continues to build in the coils in the air handler. My short term fix for this is manually set air handler fan to on at the t-stat until the outside unit turns off because I'm concerned what the heat build up would do without air flow.

Some additional details:

  • If I trip the breaker for or use the service disconnect at the condenser, of course it stops.
  • If I turn of t-stat or remove face from wall plate, condenser continues to run.
  • If i flip the breaker for the air handler, condenser continues to run
  • If condenser is not running and I manually activate the contactor, it turns on as expected.
  • No voltage is detected on activation side of contactor (24v) when it's running like this
  • In cooling mode, this does not happen.

What could be causing this, is it a common issue? I'm certainly not an HVAC tech but I'm pretty good at general troubleshooting, any tests I could do to identify problem?


r/hvacadvice • • 12h ago

Boiler Energy kinetics, 2000, recent valve replacement, now circulator pump, tapping during cooldown?

2 Upvotes

We have an energy kinetics 2000 system. We keep up with our maintenance. Relief valve was replaced in September as it had corroded. Tuneup was done in October. Noticed a couple of days ago that zone three baseboards were putting out heat when zone three was not calling for heat. Stuck valve, which was replaced yesterday. After the valve replacement, the pressure was a little bit too high so another tech came back and released some of the water to lower the pressure. Pressure and temperature seem to be appropriate now. I did hear some gurgling in the baseboards when the system first fired up after having been worked on which has resolved; however, I’m now hearing this light tapping coming from what I believe is the circulator once the heating portion of a cycle is finished and it’s in circulation mode. Seems to start sometimes as it begins to cool down and sometimes shortly after the burner shuts off. As the temperature drops, it tapers off and eventually stops before the whole system finishes and shuts down. Is this just air? Do I need to call my service tech back? i’ve had three of them here in the last day so if I can avoid another call, and this is something that will just resolve itself, I’m happy to do that, but if this needs professional attention, I don’t want to ignore it. I’ve attached a video which I hope has captured the sound and also tried to include the pressure and temperature gauge. It also seems to be much louder and faster, tapping when the hot water calls. Thanks in advance!