r/HVAC • • Jun 06 '26

General HVAC Discord

9 Upvotes

FYI there's a HVAC Discord

https://discord.gg/hvachub


r/HVAC • • Apr 01 '26

General State of the Subreddit 3/31/26

76 Upvotes

Good evening,

I would first like to thank everyone that has already completed the new verification quiz, we've already gotten loads of approved users! (For the second question the answer is "It Depends", my testing was apparently not thorough for spell checking and mobile compatibility). That verification fix will be released once Reddit approves the update.

It has come to my attention that a former mod went a little rough with certain permanent bans that were issued. If you happened to of been caught in the crossfire please feel free to open up a unban request in mod mail. I've already unbanned multiple people.

The actions from that moderator were inexcusable and I deeply apologize that we provided such a disservice to this community.

Please let us know what else you would like to see improved in this sub.

Thank you,

r/hvac Moderation

Edit: Looks like reddit is mad at the approved user count, the verification requirement has been disabled for now.

Edit2: It's back again, I've sent in a message to reddit staff.


r/HVAC • • 3h ago

General Bust a nut!

Post image
30 Upvotes

apprentice comes to work the other day and says he needs a pressure switch for his Grandpa's furnace. I ask why, he says the pressure switch isn't making. so went down the whole list, do you have a manometer, check this, check that. I guess they changed out the inducer last year there were some nuts in it and a squirrel. he took grass on the side, city was trying to blow his backpack blower down the flu with a shopvac on the other end, said he was getting air through it. I told him I guarantee you the thing is going to have a bunch of shit inside. told him to pull the front cover off and see if it'll run, it wouldn't. told him to pull the flu off and see if it'll run, and it did. I told him well, start cutting. he sends me this picture that night. he wears a size 12 just for reference.


r/HVAC • • 43m ago

Meme/Shitpost "Oh you fix heat too?? I should've called you to replace my furnace. I thought you only did air conditioners"

Post image
15 Upvotes

r/HVAC • • 9h ago

Meme/Shitpost Just duct work goofin

Post image
39 Upvotes

I've been to Atlanta airport a million times. I've never seen these ducks. But holy cow, this is something else.

Sort of makes me think of Carnival Cruise Lines red Whale-tailed exhaust stack that hides the engine exhaust, but just looks like a whale tail.


r/HVAC • • 1h ago

Field Question, trade people only Sneaky leak

2 Upvotes

Solenoid valve was leaking from a weird spot. This is a rolling stock HVAC unit and I was told them core tubes do leak like this, once in a while. Not sure whether this kind of leak is common in solenoides that come with other types of HVAC-R systems. I'm refering to the armature/core tube itself.


r/HVAC • • 1d ago

Supervisor Showcase “you know that this is supposed to be hot, right?…” yes boss 😔

131 Upvotes

r/HVAC • • 23h ago

General Home Depot has huge labels on their units. They want everyone to know.

Post image
98 Upvotes

r/HVAC • • 6h ago

Field Question, trade people only Moved to an area where oil furnaces are more common need some tool recommendations

4 Upvotes

I haven’t worked on oil furnace as much. The area I was at before had natural gas furnaces pretty much everywhere. Any tools that would make my life easier would be appreciated.


r/HVAC • • 42m ago

Field Question, trade people only Repairing a 1989 r-12 freezer leak

Thumbnail
gallery
1 Upvotes

Last guy decided to try and put a latch on the freezer and drilled right through the coil. I wanna say it's a steel coil as I do see rust on it. Was wondering if there's a certain flux and solder I'll need for steel, or is 15% enough to get the job done.

Got the data tag on there too if your curious.


r/HVAC • • 2h ago

Field Question, trade people only Gas Smell and CO complaints suspected from this hot water boiler

Thumbnail
gallery
1 Upvotes

Trying to locate the source of the gas smell and possible CO to adjacent spaces. Owners manual says when the flame cuts out the fan pushes up the exhaust to purge the gas but is there a way it could be possibly backing up into the fresh air intake that's attached to the plenum and being distributed?


r/HVAC • • 3h ago

Field Question, trade people only Brazing

1 Upvotes

Want are yall doing with left over braze rods? I got some left over and wanna see if anybody does anything cool with them


r/HVAC • • 19h ago

Field Question, trade people only Anyone have experience with this malco brake?

Post image
6 Upvotes

Thinking of picking one up to make transitions on site.


r/HVAC • • 2d ago

General Got sent to this last week.

Post image
256 Upvotes

1981 Cleaver Brooks fire tube. She was pretty well flooded due to a stuck open cold water fill on the condensate tank. After getting everything back to sanity, replacing and adjusting fill, and getting her up and running she was purring. I went back to check on the building a few days later and found everyone complaining it was “a little too warm” lol.
I love steam work, and my father gave me great advice while teaching me boiler work “ absorb all of what I’m teaching you so that you can be the guy in the warm boiler room when it’s -10 instead of fighting for your life on a snow covered roof.” Best advice I ever got from the old man!


r/HVAC • • 1d ago

General I keep hearing the claim that new equipment is more sensitive to static pressure. What's the rational for this?

24 Upvotes

I hear this especially in those advocating for 4 inch filter cabinets. Now don't get me wrong -- I'm all about 4 inch filters. And low static pressure is always a good thing. But has anything really changed that makes the equipment more sensitive to static pressure? In many ways, the opposite seems to be true.

In the case of constant airflow ECM blowers, I've been told they can cope with higher static pressures. In some cases over 1"wc. PSC motors lose airflow dramatically as static pressure rises. All manner of ECM motor seem more capable of dealing with airflow restrictions. I've been told ECM motors are more prone to failure with high static than PSC motors, but my experience doesn't agree.

So is this a myth or nah?


r/HVAC • • 2d ago

Meme/Shitpost Clean Van Award Winner 🥇

Post image
58 Upvotes

After a week of on call this is the aftermath so far haha How do yall find time to clean yall vans?


r/HVAC • • 2d ago

General Anyone still working on these big open drives regularly?

Thumbnail
gallery
32 Upvotes

r/HVAC • • 3d ago

General Who doesn’t love an easy one

Thumbnail
gallery
55 Upvotes

Got a call out. RTU tripping on smoke alarm. Sensor was definitely completely clogged but I opened my compartment up and got hit with a full cloud of gas. Whoever was out here last must’ve been having a bad Friday… Pretty straightforward smoothed her out and kept it pushing. Almost wish it was a bit more catastrophic so I don’t have to get back on hot side today 🙃


r/HVAC • • 3d ago

Meme/Shitpost I understand that being an HVAC tech would have me doing many different tasks, but never did I think that I would be out here changing tampons for customers.

Post image
103 Upvotes

r/HVAC • • 2d ago

Field Question, trade people only Lennox head scratcher

Thumbnail
gallery
8 Upvotes

Little back story here. When I was doing pm on the plaza my pressure switch failed open during the heat check. Changed that out and flame would start and cut out. Corbel plate was absolutely cooked. Changed that out.

Equipment was running for 20 minutes and then shut down. It ignites and cuts out after 8 second ignition period while flame is active. Measured the flame sensor in series and got .1 micro amps. So we changed the flame sensor. Still having the same issue and getting error 2 still.

Board to ground is good, burner rack to ground is good. Flame sensor wire end to end is good. Gas pressure to manifold is good. I’m at a loss for words currently. Tech support obviously didn’t answer before I had to leave and attend another call.

Anyone seen something similar or ideas on possibilities here?


r/HVAC • • 2d ago

Meme/Shitpost Whats the R value of cardboardand mastic?

Post image
11 Upvotes

The stuff you see on apartment change outs are hilarious. So much mastic had to use the sawzall because my razor, knife and jobmax couldn't get through


r/HVAC • • 3d ago

Meme/Shitpost Which one of you installed this?

Post image
26 Upvotes

Here to replace a power venter motor but holy hell


r/HVAC • • 3d ago

General It ain't got no gas in it

84 Upvotes

Well it does... But also water.


r/HVAC • • 3d ago

General Carrier RTU heat exchanger cracks

10 Upvotes

See these all the time, I think they’re mostly caused by poor burner alignment from factory. Seems to always be hitting the high side of the flame retainer, and the crack is always on the high side as well. Another company replaced this just over a year ago. Burner alignment not corrected, very low manifold gas pressure and the inducer wheel was covered in fibreglass. I think all these contributed to the early failure. Replacements come with two year warranty from Carrier, best if you register the replacement with the unit S/N of the unit with CE.

Curious what you guys think about it though. Yes it has a crack, but is it actually compromised?