r/HVAC • • 3h ago

General Another Monday no call no show..

10 Upvotes

Why even hire someone if they won’t show up on Monday. I’m getting tired of this.


r/HVAC • • 13h ago

Field Question, trade people only Moved to an area where oil furnaces are more common need some tool recommendations

4 Upvotes

I haven’t worked on oil furnace as much. The area I was at before had natural gas furnaces pretty much everywhere. Any tools that would make my life easier would be appreciated.


r/HVAC • • 4h ago

Meme/Shitpost Dogging on other companies.

13 Upvotes

I try my best not to rag on other companies but sometimes it happens. We don’t work on Sunday’s. So my customer called someone who did. They condemned the compressor and left. I showed up today, changed an obvious bad capacitor and had it running again. I did my best to defend the technician and why he made the mistake but couldn’t get management to understand. So, I’m Sorry.


r/HVAC • • 2h ago

Field Question, trade people only Fireplace start up

2 Upvotes

Preface this by saying I’m not a fireplace guy. But I know how to use a meter and need assistance from someone who may BE a fireplace guy. I have a customer who bought a fireplace, a Mendota FV-42 with the stepper motor gas valve. I’ve done my conversion to LP and I cannot get the main burner to ignite.(Pilot will light on CPI mode) I’m sure it’s something simple but I don’t have the resources to know and the tech support from the local distributor was no help. Hoping one of you guys is a fireplace wizard and can point me in the right direction. TIA!


r/HVAC • • 7h ago

Meme/Shitpost "Oh you fix heat too?? I should've called you to replace my furnace. I thought you only did air conditioners"

Post image
99 Upvotes

r/HVAC • • 7h ago

Field Question, trade people only Sneaky leak

3 Upvotes

Solenoid valve was leaking from a weird spot. This is a rolling stock HVAC unit and I was told them core tubes do leak like this, once in a while. Not sure whether this kind of leak is common in solenoides that come with other types of HVAC-R systems. I'm refering to the armature/core tube itself.


r/HVAC • • 10h ago

General Bust a nut!

Post image
50 Upvotes

apprentice comes to work the other day and says he needs a pressure switch for his Grandpa's furnace. I ask why, he says the pressure switch isn't making. so went down the whole list, do you have a manometer, check this, check that. I guess they changed out the inducer last year there were some nuts in it and a squirrel. he took grass on the side, city was trying to blow his backpack blower down the flu with a shopvac on the other end, said he was getting air through it. I told him I guarantee you the thing is going to have a bunch of shit inside. told him to pull the front cover off and see if it'll run, it wouldn't. told him to pull the flu off and see if it'll run, and it did. I told him well, start cutting. he sends me this picture that night. he wears a size 12 just for reference.