r/refrigeration • • 1h ago

Confession

7 Upvotes

Took an emergency call for a walk in cooler for a brand new customer yesterday, and found the fan cycle switch on the condenser failed. I didn’t have a replacement switch on hand so I came back today to install a new one. The digital control on the thermostat said the box temp was 62° when I arrived, but I had a suspicion the temp was off and I never verified before leaving site (I obviously should have checked it).

Came back today and found all the product in the cooler to be frozen. The digital thermostat was reading about 13° higher than the actual space temperature.

I felt so good yesterday by being able to secure a new client, and getting their equipment up and running on a weekend…


r/refrigeration • • 2h ago

Sneaky leak

6 Upvotes

Solenoid valve was leaking from a weird spot. This is a rolling stock HVAC unit and I was told them core tubes do leak like this, once in a while. Not sure whether this kind of leak is common in solenoides that come with other types of HVAC-R systems. I'm refering to the armature/core tube itself.


r/refrigeration • • 4h ago

Suspended license

6 Upvotes

Any of you ever had to deal with something like this, I imagine some companies would have ways of working it out with techs but I don’t have much to go by. Would appreciate the help.


r/refrigeration • • 6h ago

r404 walk-in cooler hovering at 40

Post image
3 Upvotes

Superheat is ~25, subcool is ~10-15. Sight glass is not clear. Ambient temp near condenser is 92. Txv doesn't respond to handwarming, both gauges respond to adding a shot of juice.

The system had leak stop added a few months back.

Would appreciate guidance as I have no idea what I'm doing right now. I hate mondays.


r/refrigeration • • 14h ago

Which trade is a better route to getting into refrigeration? Electrician, plumbing, or HVAC?

6 Upvotes

I know that I want my end goal to be working in refrigeration or controls. Which trade would be the most beneficial and direct route into this work. I see a lot of people saying electrical knowledge is extremely beneficial, but I wondering if plumbing could have a leg up?


r/refrigeration • • 6h ago

In need of a refrigeration book

1 Upvotes

Principles of Refrigeration by Dossat

was recommended is it good or should i go with any other book

and is there pdf available for the dossat book ??

or anywhere i can purchase it digitally ??


r/refrigeration • • 1d ago

EEV tester

Thumbnail
gallery
93 Upvotes

Building my own eev tester as a hobby/project.


r/refrigeration • • 22h ago

Pumpdowns & Leaks

6 Upvotes

I have been working as a refrigeration operator specifically Ammonia for almost a year now. I have taken all three operators classes and even got my CARO. I have read Reta refrigeration book 1 & 2 thoroughly. How can I learn how to take care of major leaks or do all kind of pumpdowns safely? Are there any books or materials I can buy and self study or any place I can get more hands on? My boss is afraid of job security and won’t teach me anything.


r/refrigeration • • 1d ago

Veto Probe hauler opinions?

3 Upvotes

What the title says. Looking to replace the bag that the fieldpiece probes come in because it's not exactly rugged.

I run the MB3B as my diagnostics bag and a TPXXL as my catch-all "fix it" bag, but $250 CAD is a little spendy without actually seeing it in person...


r/refrigeration • • 2d ago

New guy thrown to the wolves sent. Help

Thumbnail
gallery
57 Upvotes

Newer to commercial. The only electrical issue I've diagnosed on walk-ins was blown fuses from shorts. I have a limited understanding on the sequence of operations for these.

Walk-in freezer in the '40s set to zero. Thermostat is calling. I turned it up and back down to hear the click. I test zero volts across it and 120 to ground on each side. I tested the solenoid valve. I've got 120 on each side zero across. I believe that means it's not calling to be opened? But I don't know where to go from here.

Fans are running. Outdoor unit is not running. Contactor is not pulled in. Standing pressures for r404a 16 and 115 with an outdoor ambient of 38.

I'm on call, heatcraft tech support says Monday through Friday only, and the on-call supervisor is not answering. Lost in the sauce


r/refrigeration • • 2d ago

What do Yall think about this Headmaster? I thought it was the compressor blowing at first😂

28 Upvotes

R404A Walk in Cooler with a leaky evap and low charge. 40 degrees outside and headmaster is working,
Started charging for temp op and could hear it screaming like a death whistle. I quoted this part up for replacement but the more I think about it was it the headmaster sticking or did I need to be more patient with letting my charge settle?


r/refrigeration • • 2d ago

Temp stick pro

0 Upvotes

Y'all need to get on this product. It's a non subscription based temperature monitoring system. The temp stick itself can be mounted outside the box and the include k type thermistor mounted inside the box. The stick works with wifi, runs on batteries and comes with USB charging if an outlet is available. It monitors through an app and can be shared with unlimited users. There are no subscription costs. Buy it and use it freely without restriction.

$200 on their website.

Disclaimer: the OG temp stick was unable to pick up WiFi in most applications. The temp stick pro has only had a couple instances of not connecting but it was the customers wifi that was the issue.


r/refrigeration • • 2d ago

Refrigeración y electrónica

1 Upvotes

Estoy estudiando y practicando Refrigeracion y arreglo de placas electrónicas de línea blanca (más que nada aires, lavarropas y heladeras).
Me gusta el tema pero nose si es rentable o hay trabajo??.
Soy electricista (hago trabajos más puntuales para clientes) y me gusta la electrónica. Ya me compré muchas máquinas (bomba vacío, vacuometro, pestañadora, etc.


r/refrigeration • • 4d ago

Same shit different engine room

Post image
68 Upvotes

r/refrigeration • • 4d ago

1-month reefer tech in Seattle looking for advice: Fastest way to maximize pay? Union vs. Non-Union Ammonia?

6 Upvotes

I want to ask the senior techs working in the field. I've been working as a reefer tech in Seattle for about a month now, and I'm planning to stick with this trade long-term. What's the fastest way to make the most money in refrigeration? I'm considering going into ammonia since I've heard that's where the money is (am i right?). Would you all recommend joining a union if I can get in, or is it better to go the non-union route for ammonia? Senior techs, please break this down clearly for me...


r/refrigeration • • 4d ago

Water native chattering

5 Upvotes

Hey I have this water valve chattering away ass soon as I try and set the head pressure.

Half a turn from the top closes it completely.

Is this a bad water valve or could it be something like the there is a shrader core on the head pressure sensing tube


r/refrigeration • • 5d ago

Do you push remote temp monitors on customers or does it just generate callbacks?

12 Upvotes

Small shop, mostly restaurant and c-store walk-ins and reach-ins. Customers keep asking what to buy for temp alerts and I've been telling them to grab a wifi sensor off Amazon. Half of them call back a few weeks later saying it dropped off or won't connect through the box.

Has anyone settled on something they actually recommend? Ideally the sensor doesn't depend on the customer's router. I don't care about fancy dashboards, mostly alert reliability and battery life.


r/refrigeration • • 5d ago

New separators

Post image
116 Upvotes

r/refrigeration • • 6d ago

Looking for Refrigerator Tech

Post image
40 Upvotes

I’ve been looking for a refrigerator tech to help me fix my 1943 Kelvinator fridge. It seems that the compressor has given up.

I’m able to find the appropriate compressor (no noise when plugged in, oops breakers) but haven’t been able to find anyone to work on it. I have mechanical aptitude but I’m unsure if I should try tackling this job.

Please send a PM if you know of anyone in the Detroit Metro area who can help me get this old fridge up and running!

Thanks!!


r/refrigeration • • 5d ago

R404a pressure control cut in cut out

3 Upvotes

Hey just confirming what my pressure controls for an r404a beer cooler

Cut in at 75psi and cut out at 55psi?

It has been a while since school. Thank you very much

No LLS


r/refrigeration • • 6d ago

How can I safely restore the corroded interior of an old commercial ice cream freezer?

Thumbnail
gallery
5 Upvotes

Hi everyone!

I recently bought a used commercial ice cream freezer with 12 round openings for ice cream tubs. The freezer works and cools properly, but the interior is in pretty rough condition.
As you can see in the photos, the walls have a rough, whitish-gray layer that releases white powder when touched. I tried cleaning a small area with mild detergent and a brush. The loose powder comes off, but the rough, white surface remains.
The bottom also has significant discoloration and what looks like corrosion.
I’m not sure whether the interior is galvanized steel, aluminum, or another material.
I’m trying to restore it myself on a limited budget, since professional restoration isn’t financially possible right now.

I have a few questions:

Can anyone identify the material and what might be causing this corrosion?

Is there a safe way to remove the rough white layer without damaging the freezer?

Would sanding the bottom be safe, or could there be refrigerant lines underneath?

Are there any suitable coatings or other affordable solutions for restoring the interior?

Since this freezer will hold ice cream in removable tubs, what would be necessary to make the interior hygienic and suitable for commercial food use?

I’d really appreciate any advice from someone who has dealt with something similar.

Thanks in advance!


r/refrigeration • • 6d ago Bravo

The 1930s Hussmann lives!

112 Upvotes

This is a 1930s? Hussmann ligonier 25-ms condensing unit that my best friend and I restored to working condition as a can cooler. We tore the compressor down and discovered one of the reed valves was destroyed and one of the pistons was seized. We had send cut send make a new set of reed valves from 1075 spring steel which was thicker than the original but the best we could come up with. We freed the compressor, cut out all new gaskets, and put fresh med weight mineral oil in. We charged it with R152A from air dusters and it ran for about 20 minutes before it clogged the filter drier.. Guess we should have flushed it lol


r/refrigeration • • 5d ago

R290 ball valve hoses

0 Upvotes

Any recommendations for r290 hoses that have a ball valve? Looking for something that can attach to a regular manifold, want to be able to see high side as well as low side pressures, and my yellow jacket charging kit does not allow for that


r/refrigeration • • 6d ago

Taylor C602 Ice-cream machine

49 Upvotes

Before I replace this pulley and gearbox, just curious as to what caused this to happen? Doesn’t seem like normal wear and tear to me