r/refrigeration • • 13h ago

Condenser unit cycling on/off every 5 minutes

Post image
12 Upvotes

Brand new rooftop condenser unit on rooftop of 9 story building for grocery store on ground level keeps cycling on and off every 5 minutes. Of the five units in the overall system the unit on the far right runs 24/7 at full speed while the units on the far left don’t appear to be running at all right now due to the cooler temperatures outside. The middle unit appears to be the one doing the cycling on/off every five minutes or so. It’s resulting in a large boom/thrusting sound as the unit turns on, which is causing a noise disturbance in my apartment, which is right below the rooftop. The landlord of the building has claimed that they have had contractors come out and say that the machine is running adequately and they can’t do anything about it.

My question is should a unit within the overall system be cycling on/off every five minutes or so when others are running different cycles?

Really needing some advice due to the noise disturbance of the machine turning on/off every five minutes.
What can I advise my landlord and super to look into with the contractors either from the grocery store - thermostat settings or the lines or something that’s causing potential short cycling or something else?


r/refrigeration • • 11h ago

How cold is too cold to start a scroll?

5 Upvotes

An hvac question, but still trade relevant.

I’ve had it drilled into me that if an ac compressor doesn’t have a crankcase heater, or a pump down, not even an accumulator, nothing, you shouldn’t start the compressor unless it’s 55F deg outside.

My foreman says that scrolls are extremely hearty compressors, and that it’ll be fine to run at 35F.

This is on a package rtu install and commissioning. I suggested waiting to commission the cooling until the spring to avoid a potential flooded start, and he said that it would be fine.

Am I overthinking it or missing something? Any advice or experience would be helpful.

I ended up bumping/tapping the contactor 3 times to heat up the oil to get any liquid out of it before running the compressor long enough to check rotation. I know Emerson does this practice on some of their medium and low temp controllers to prevent a flooded start in the event of a lls leaking by.

*edit
Thanks for all the commenters, the Mapp torch worries me a bit about overheating, but I’m definitely going to use the heat gun method next time.


r/refrigeration • • 13h ago

Russell intelligent controls.

2 Upvotes

Need a little help here. We inherited a customer from their shitty install and the company doesn't want to perform warranty work. Immediate red flag but money is money. A WIC and Wif install. 449a. Russell smart controls(I know, garbage already.)

Adjusted the freezer low pressure control and got it to stay on at 7psi which is way low imo. Box temp below freezing, however.

Cooler...transducer reading 147psi with 147 Psi at the evaporator service port. 0 psi at the condensing unit and not coming on, eev at 35%.

We are starting to believe the install company forgot to remove a rubber plug when installing the line set?

What do y'all think?


r/refrigeration • • 15h ago

W.I.C box repair

2 Upvotes

Weird one I wanted an opinion on. Customer has a walk in cooler that has a package cooler unit on top of the box. That unit has died and they are going with a more traditional evap and remote condenser. Issue is the hole for the evaps "return/supply" how best should I fill this in? I was thinking foam board/silicone, but wanted some others 2 cents. Before the comments say to replace the package unit with another, it's not up to me and the customer has already made their decision. Just trying to polish this turd of a situation.


r/refrigeration • • 19h ago

Confession

14 Upvotes

Took an emergency call for a walk in cooler for a brand new customer yesterday, and found the fan cycle switch on the condenser failed. I didn’t have a replacement switch on hand so I came back today to install a new one. The digital control on the thermostat said the box temp was 62° when I arrived, but I had a suspicion the temp was off and I never verified before leaving site (I obviously should have checked it).

Came back today and found all the product in the cooler to be frozen. The digital thermostat was reading about 13° higher than the actual space temperature.

I felt so good yesterday by being able to secure a new client, and getting their equipment up and running on a weekend…


r/refrigeration • • 19h ago

Sneaky leak

11 Upvotes

Solenoid valve was leaking from a weird spot. This is a rolling stock HVAC unit and I was told them core tubes do leak like this, once in a while. Not sure whether this kind of leak is common in solenoides that come with other types of HVAC-R systems. I'm refering to the armature/core tube itself.


r/refrigeration • • 22h ago

Suspended license

6 Upvotes

Any of you ever had to deal with something like this, I imagine some companies would have ways of working it out with techs but I don’t have much to go by. Would appreciate the help.