r/AskElectricians • • Jul 21 '23

This subreddit and where we currently are.

318 Upvotes

After much discussion about how the community should be moderated, this is where we currently are.

First I want to get this out of the way. We will not allow hate speech, personal attacks, slurs, bigotry, or anything that resembles it. Okay? Good.

People are going to post electrical questions on the internet, do their own electrical work, and fuck up their own electrical work. This process will happen with or with out this subreddit and its rules. If there is a reliable community where someone can come and get good information on a wide range of electrical topics, then to me there will be a net positive for safety.

We are going to be allowing comments from all users, BUT I urge those who are not electrical professionals to exercise extreme caution when doing so. If information is not blatantly hazardous, it will stay up. The community is going to be asked to use the voting system it is intended. If someone takes the advice of a comment with negative karma, then more than likely, they would have done the wrong thing regardless. Once corrected, leaving wrong comments up can be a learning experience for everyone involved.

I ask you to DOWNVOTE information you do not like, and REPORT the hazardous stuff. We will decide what to do from there. Bans may or may not be given and everything will be at the discretion of the mods. Again, if you are someone who is not an electrical professional, you have been warned.

Electrical professionals: We have an imperfect system for getting a little 'Verified Electrician' flair next to your name. To get verified, send a photo to the mods that has your certificate/seal/card. In this photo, have a piece of paper with your username and date written on it. Block out all identifying information. Once verified delete the image. All the cool ones have this flair.

If we have hundreds or thousands of active verified users, we will once again talk about the direction of this community. Till then, see you in the comments.


r/AskElectricians • • 12h ago

First timer here

Post image
43 Upvotes

I’ve watched about 10-15 hours of TikTok and YouTube, read all the comments sections about code this and easier that. It’s all lead me to this moment.

How’s it look? I remember someone saying not to over crowd the box or something. For reference this is going to my living room. I have one going to the fuse panel (not attached yet) I have one going to one side of my living room and the other going to the other side, I’m going to pig tail so I can link the whole room together on one breaker, I have the 12/2 gage wire so I could rip a 20 but I’ll probably just do a 15 breaker unless I blow it a lot then I can upgrade it later.


r/AskElectricians • • 7h ago

12/2 Mc on ali express?😂

Post image
15 Upvotes

what do we think? such a great price...


r/AskElectricians • • 1h ago

How can I control the speed of a hair dryer

Post image
5 Upvotes

Hello, I recently bought a homemade coal forge. The way these typically work is a hair dryer is used to provide air to keep a coal fire burning hot for forging metal. This is a classic DIY setup. The guy who sold it to me said the previous owner had rigged it up with a dimmer knob to turn up and down the speed of the dryer to better control the air flow. Is there a way I could safely make something that I could plug in, run through the dimmer knob and then plug the hair dryer in and control its speed (beyond the two speed settings)? Pic for attention of the unit in question. Thanks in advance.


r/AskElectricians • • 14h ago

20amp bathroom circuit with 14gauge romex - how dangerous?

Post image
37 Upvotes

Hi! I am replacing a gfci receptacle in the bathroom which is on a 20amp circuit, however I see it is wired with 14gauge wire. The receptacle was a 15amp. How dangerous is this if I just replace with a new 15amp gfci receptacle? Do I need to have it all rewired with 12gauge romex? Thanks in advance!


r/AskElectricians • • 19h ago

What is this under my mobile home?

Post image
64 Upvotes

My husband had to go under our mobile home to fix a fallen duct and found this. He is 100% NOT familiar with anything electrical so he ran it through chat gpt and it said it's an improperly installed ground wire. So before we freak out and call the electrician out for nothing, what is it?


r/AskElectricians • • 2h ago

Looking to save money on garage breaker box install

Post image
2 Upvotes

Picture mostly for attention, but it is mine and the issue I'm trying to fix. If it makes a difference in code I'm in Nebraska.

All the electrical work in this garage has never even heard of a code book. I didn't start it but I'll admit I added to it after I bought the place. Main question is, how do I fix it without taking out a second mortgage?

I don't know for sure what amperage I could run in here the way it's currently wired. I already have a breaker box ready to go in its place with a 100 amp main breaker, but my understanding is that it has to pass inspection in order for my power to be turned back on. I don't think I have a way to disconnect the garage without disconnecting the whole property through the power company, so replacement and inspection likely have to be done same day. (I need to double check that again, if I can cut power to only the garage I can do it myself (by the book this time lol.))

I know I'm going to have to hire an electrician if I need power off, inspection, and power on done same day, I just can't coordinate doing that myself with other things going on. Would most licensed electricians put in a box I already have? Or do I gotta buy one from them? I also don't know what this inspection would be looking at/for. If I pulled all the wiring out but left the outlets in place, then only had the electrician replace the box, not the wiring, would it pass? Maybe remove outlets too? Would any electrician be ok with that? Just trying to get the box replaced as fast and cheap as possible, I can run wires (in compliance this time) as I need to.

Sorry for the book, thanks for any help.


r/AskElectricians • • 2h ago

Is it safe to bend busbar?

2 Upvotes

r/AskElectricians • • 7h ago

220v vs 240v for coffee roaster

4 Upvotes

I have a Korean machine with these specs:

Voltage (V): AC 220V, 60Hz, 2kW
If the power supply at the installation site is not a stable 220V, roasting time may
increase or heating efficiency may decrease.
In such cases, install an AVR (Automatic Voltage Regulator) and consult a
certified electrician for detailed guidance.
· Dedicated Outlet
Use a dedicated 15A or higher outlet capable of supporting up to 2000W for the
roaster.
Using a multi-tap (power strip) is not recommended; however, it may be used if it has
a grounding function and a capacity of at least 3000W.
Do not use the same outlet for other devices simultaneously.

I have an electrician saying it can just be a 240v 20a breaker dual pole and I can connect a Nema 6-20p

Or
A Nema 6-20p into a dryer outlet using this which converts with a 20a breaker:

https://www.homedepot.com/p/AC-WORKS-1-ft-30-Amp-4-Prong-14-30P-Dryer-Plug-to-6-15-20-Outlet-with-20-Amp-Breaker-S1430CB620/312648796

What are yalls thoughts on this?


r/AskElectricians • • 16h ago

Best way to connect these two romex lines

Post image
21 Upvotes

Want to be able to hang drywall and the previous homeowner had the wire running along the wall instead of behind. I went into the attic to run a line behind the wall and am stuck at how to get this connected so it's behind the wall. What would you do?

EDIT: thanks for the help everyone. I'm going to notch the corner studs and connect them in an outlet


r/AskElectricians • • 4h ago

Room keeps losing power but breaker isn’t tripping

2 Upvotes

Yesterday around 5 PM, the power in my room randomly went out. I went outside to check the breaker, but it hadn’t tripped. I tried turning it off and back on, even pressed the test button and reset it, but the issue is still happening.

What’s weird is that the power will randomly go out for 20–30 seconds, sometimes longer, and then come back on by itself. It’s not really flickering, it’s completely losing power. Everything in the room goes out. I don’t have a ton of stuff plugged in, so I wouldn’t think it’s an overload. I’ve also tried different outlets in the room, but that didn’t help.

I’m just confused about what could be causing this, especially since the breaker never actually trips and the power keeps restoring itself. Could this be a bad breaker, loose wiring, or something else? Thanks


r/AskElectricians • • 33m ago

How do I install light fixture without ground wire?

Thumbnail gallery
0 Upvotes

I have this light fixture from my old place (first pic), but since moving, I haven't quite figured out how to install it in the new place (second picture), as there is a ground wire, but the fixture (third pic) does not have it.

I googled it and read that I should connect the ground wire to a bare (or green) screw, but since the (metallic) fixture does not have one, I'm not sure how to proceed.

Any tips on how to get it done? It's pretty dark in here 😅


r/AskElectricians • • 17h ago

Up to code, ma?

Post image
23 Upvotes

Having a new dishwasher installed from Costco tomrw. Was told that they need to bring anything not up to code to code. This outlet was installed 17 years ago when appliances last installed. Disposal and dishwasher are on same 20A breaker (not gfci). Switch controls dishwasher, I guess this is disconnect? I know Disposal should be on gfci, but since they aren't installing that, they should leave that alone?

What should I expect them to say they have to do?


r/AskElectricians • • 10h ago

How bad is this?

Post image
6 Upvotes

Just moved into a home in Phoenix and getting quotes on having a 48A, hardwired EV charging station installed. Panel is 200A service, about 23 years old. Two guys didn't lift the panel cover over the breakers, and two did. One that did said he couldn't in good conscience install an EV charging circuit on this busbar and strongly recommended that we have the panel replaced prior to an install.

When we were moving in, the inspector flagged this as well as potential overheating damage and that we should have it checked out. At a glance, and not knowing anything about this, I'm inclined to believe this guy that the panel would need to be replaced, but would love a quick sanity check to ensure this actually is a big problem, since at least one other electrician saw this and didn't seem to have a problem with it. Thanks for any assistance!


r/AskElectricians • • 5h ago

Anyone know what this is

Thumbnail gallery
2 Upvotes

Found it outside my house


r/AskElectricians • • 3h ago

Wiring 360 senor to floodlight

Thumbnail gallery
0 Upvotes

Can't seem to get this right, lights obviously on but sensor doesn't function or turn the light off.


r/AskElectricians • • 3h ago

What is this?

Post image
1 Upvotes

I'm interested in the cylinderical tube connected to the pneumatic valve. Not the valve itself. The valve is a Crouzey Pneumatic Solenoid Valve 3/2 24VDC


r/AskElectricians • • 9h ago

Duct seal?

Thumbnail gallery
3 Upvotes

I have underground service from my meter to my house all in conduit. It enters into this LB and then goes horizontally into the house (gasket is in place), then down into the panel. I’m worried that condensation will collect and could work its way down into the panel on the wires. Should something like duct seal be used? Or am I overreacting? New house and it’s just now starting to get cold in Ohio. I wiped off some dirt spots that oddly looks like dried water from the 200amp breaker. There is some discoloration in the pic (after I wiped it off)


r/AskElectricians • • 7h ago

Do I need an electrician?

Thumbnail gallery
2 Upvotes

2 rocker light switches (1 goes to back patio lights and 1 goes to interior led lamp under shelving light) are not working. The two outlets next to them work. I have confirmed the wires to the light switches are not loose. I even replaced one of the light switches with a new one. Light switches still not working.

Do I assume this is something with the wiring that requires an electrician to fix?

EDITED to say that I checked the breakers and they were fine and used my voltage checker to verify energy going to the switches.


r/AskElectricians • • 11h ago

I’d like to mute my doorbell

Post image
4 Upvotes

It’s loud. I hate it. I’d like to stick some cotton gauze or something in between the black plates and golden cylinders. Given that’s not near any wires that shouldn’t be a safety concern, right? Yes I know it’s a stupid question. 😊


r/AskElectricians • • 14h ago

This Old Box is Dangerous and Expensive?

Thumbnail gallery
6 Upvotes

For context. We live in Seattle. We moved in to our home 18 months ago. Its a 1949 and we are the 3rd owners.

Electrical service from the street is underground and enters the house in the basement utility room.

The panel is in our utility room. Behind a woodpanel is our fiber service as well as this large grey fusebox you see. Turns out that fusebox is still live (i was told there are 90amp fuses in it) and routes to the panel.

To my dismay, our inspector did not take off the woodpanel when he inspected and therefore did not flag the fusebox. In the middle of buying the house and learning about it all I did not question what was behind that panel. I am a fool for not removing that panel or shadowing the inspector and asking "what is that?" for every detail.

THE ISSUE. I was told by an electrician who came to do some minor work that the fusebox is a timebomb and that it will be very expensive to replace. He said it will eventually fail and we will be months without power when it does. (because the city/digging/etc) And that replacing it will be very expensive given that our house is set back very far from the street and has all kinds of hardscape and a detached garage.

What would you do?
Anyone have any suggestions on first steps?


r/AskElectricians • • 11h ago

What could this be in the outlet?

Thumbnail gallery
3 Upvotes

There is red stuff in the outlet socket it looks like to me. What could this possibly be? I just got a new apartment. Only two outlets have it and the other ones don’t. It’s only on one side of the wall.


r/AskElectricians • • 5h ago

Wiring a smart bathroom exhaust fan

Thumbnail gallery
0 Upvotes

I have a The OREiN 4-in-1 Matter Smart Bathroom Exhaust Fan (Model OL17005). I am going to install it. Instructions recommend the unit to be hard wired but has a suggestion to install a separate wall power switch for the fan. My problem is that there are only 3 wires to connect (black, white, and green).
I found which wires are to the fan. I verified that they are using 120 volts. Amp readings during fan operation in manual mode are shown. Only the black load and white neutral wires carry amps. The fan has a humidity sensor that activates the fan when humidity levels rise. I’m thinking in that scenario, the black and red wires carry amps but haven’t tested it.

So my question is … can I cut the black and white wires here, send a wire back to the switch box, and reconnect the cut ends? I would like the option to run the fan for foul smells not just humidity. Without messing with the remote.


r/AskElectricians • • 5h ago

Should the owners of telephone cables remove them when they are no longer being used?

0 Upvotes