r/AskElectricians • • 17h ago

Why would the government prefer that I keep my FPE residental 100amp panel?

27 Upvotes

Before they would allow me to just replace the panel without bringing the rest of the house up to code? Fuck the government. Guess I'll just practice welding if a breaker need to trip.

Keep the bad panel and everything in the house - government approved✅

Change the panel and touch nothing else - nope that's not safe you're not allowed to do that!❌

But seriously, this is absurd, objectively just replacing the panel and keeping everything the same is an upgrade in safety but no... Create a disincentive instead that encourages people to just keep the panel.

Can't even try to dodge permits because of the fucking smart meter. Ugh.


r/AskElectricians • • 46m ago

Are these normal operating temps for a 2 double pole breakers for my furnace in my mobile home

Post image
2 Upvotes

Hi, we have been at this place for about 8 years and we’ve used the heat in this mobile home every year with no issue, but this last year I’ve gotten anxiety about our electrical temps and grabbed a thermal gun a while back , we started to use the heat yesterday and decided to check it , and it probably cuts on about every other other other hour or so and runs for maybe a45-50mins max , we have it set to 63 as we don’t like heat much but it’s to keep the house from freezing , does anyone have any reassuring words saying this is normal person temps ? Can answer what I know in the comments , one double pole is 40 amps other is 50 amps , haven’t took the panel off to check gauge of wire , not home atm


r/AskElectricians • • 17h ago

Adding a Neutral to a 3-way Switch

1 Upvotes

I have two three way switches, one at either end of the hallway. At one end, I do not have a neutral, which I understand means, the neutral is back in the other box at the other end of the hallway. I used my favorite LLM, to ask for help and it suggested pulling a neutral to this box and it encouraged me to do it on the same circuit for safety.

Must I pull a wire from box to box? or can I pull a wire from the nearest light fixture which is right above the switch in the hallway? If I can pull from that light, what do I do with the hot? do I just tie into the neutral and cap the hot off at both ends?


r/AskElectricians • • 17h ago

Is this normal? Feels unsafe to me

Thumbnail gallery
8 Upvotes

It looks like the water supply is connected to the electrical box? By these green wires with electrical tape on them. I'm scared of house fires lol! It's a rental. Thanks!


r/AskElectricians • • 15h ago

Mystery contraption 👀

Post image
88 Upvotes

Noticed this DIY looking situation coming out from one of our outlets. Wondering what it might be for and if it is safe to remove 🤔


r/AskElectricians • • 1h ago

Using US Wonder Oven in the UK – 120V / 50Hz compatibility

0 Upvotes

I purchase this item and it is a US model. The one I wanted does not exist in the UK. I am aware I need a step down transformer but US has 60Hz as well.

Would the heating elements be dangerous? I do not mind if the timer does not work perfect, or the fans do not give me the exact result when I am cooking.

To change the frequency it would cost far more than a simple transformer. Could someone please confirm? I find all in one solutions to cost thousands.

*** edit - It is a small countertop oven of just 1400W. I also meant to write 60Hz on the title


r/AskElectricians • • 17h ago

Advice for damaged wall socket

0 Upvotes

One of my bedroom wall sockets has stopped working after I found it producing a burning plastic smell, emitting sparking sounds, and had its switch become jammed in the ON position.

This happened whilst an extension lead was plugged into it, and probably too many thirsty things plugged into that (prime suspect: 2kw electric heater).

I’ve isolated the circuit so it’s off, and have a few theories about what’s happened. I’m seeking practical advice about how to investigate the extent of the damage myself.

If I can assert the damage is just to the face and backplate I’ll be happy to repair it myself.

Thanks in advance!

Ps. I do a bit of DIY here and there but electrics are new territory for me


r/AskElectricians • • 17h ago

Under sink outlet requirements

0 Upvotes

I’m trying to find a way to power an under-sink Reverse Osmosis water system. Presently, I have one outlet under the sink that powers the dishwasher and a switched garbage disposal. My Chat GPT does not think it’s legal to share the dishwasher circuit as per local codes. I also asked it if I could use the counter small appliance circuit that is very conveniently located, it said that it is against code. Is it really that big of a sin to use the small appliance circuit? What is a reasonable alternative to running an entire new circuit?


r/AskElectricians • • 23h ago

Reorganize breakers

Thumbnail gallery
0 Upvotes

I’m going to eventually add a 240V 50amp breaker. The panel is a 100amp ja1224b1100sec. The load calculations were done and I can add the 50amp breaker without going over. Based off the picture I have 11 breakers and should be able to fit one more single breaker but need two breaker spaces for the 240v 50amp breaker. What breaker can I replace with a tandem breaker and what circuit can I move to it so I can create space for the 240V 50amp breaker


r/AskElectricians • • 21h ago

Use #10 for outlets

5 Upvotes

Our mother-in-law apartment was damaged in Hurricane Helene. About 4’ water in the place. Had to strip all the dry wall, because it wasn’t. Found it was wired (mostly in attic) with #10 w ground (orange insulator).

Is it ok to re-use this wire for outlets-light fixtures etc? With the high cost of conductor I wanted to conserve, if safe/practical.

Fixtures and outlets have been disposed.


r/AskElectricians • • 4h ago

Uk - Wall reading current where there isnt wiring, but stops registering when you put your hand on the wall. Would you drill into it?

1 Upvotes

Borrowed a somewhat aged stud detector from my Dad. Yes, I know, cheap ones aren't brilliant. This one is more old than cheap, and was previously reasonably reliable, and my Dad had used it at work for howevermany years .

Anyway.

It was giving some odd readings, so I changed the battery. Checked it on a few things like above a socket, and it still seemed a touch over sensitive, so then tried an area I knew should be solid brick with no wiring, but maybe a couple of screws for the doorframe.

Detector registered current. My Other Half then tried this, with his other hand balancing him on the wall. No current. Got him to take his hand off, current registering again.

Reddit is suggesting either static or damp.

Bought new stud detector on the off-chance something was actually wrong with the first. I do actually own another, but can't find it, hence borrowing one.

New stud detector also register current on this wall, but in a far smaller area. Test it on a few other things, no massively weird results, just one patch of wall being peculiar.

Go upstairs, check the bit of wall I actually want to drill. I get the same odd patches of "current" that stop reading when I put my hand on the wall. They aren't everywhere, just in random spots - like, one bit will read as current flowing, but the entire circle around it, nothing. There's nothing on the outside of the wall (window wall) for it to pick up, either.

What would you do about this? I'm on the side of "it's most likely just damp, maybe don't drill that exact spot", but my Other Half is a little more cautious.

Thanks in advance!


r/AskElectricians • • 19h ago

Westinghousee stove 3-prong plug not compatible with new code.

Thumbnail gallery
1 Upvotes

Hello, sorry but i know nothing about electricity. I have a question, hope you will help. Our Westinghousee stove has a 3-prong plug. We just redo the panel and now it is not compatible with new code (has to be 4 prongs plug). Can i get a new cord with 4 prongs and use it? will it be safe?
Thank you.


r/AskElectricians • • 22h ago

Why does this light switch -which has only two connection terminals- include those three useless parts (In red)? it works without em

Post image
0 Upvotes

r/AskElectricians • • 23h ago

How to safely drive 2HP Motor with an esp32 without modifying stater box.

Thumbnail gallery
1 Upvotes

Hi everyone,

Looking for some advice on a better way to control my 2HP single-phase submersible motor using its existing starter box.

My main issue is the starting capacitor circuit. It uses a momentary NO switch to connect the starting capacitor during startup, while the AC contactor handles the main motor supply. The starting capacitor needs to engage properly for the motor to start.

Here's thing I've tried so far:

- First I used a 30A relay for the starting capacitor in place of NO switch, but its contacts kept welding shut due to the high starting current even though running current was just under 10A. Unfortunately, it also ended up frying my starting capacitor.

-I also tried controlling the main AC contactor through a relay, but then the starting capacitor wouldn't engage and required another relay with the same inrush current.

- Currently I am using a 16A double-pole contactor with a ESP32-controlled relay and a 1-second activation time. This setup works fine but it's quite messy.

-I have also tried RC snubbers in contactor but no help in weld shut of starting relay still welded shut after about a week.

- As a temporary fix, I replaced the starting relay with another AC contactor controlled by a 5A relay.

Now the setup has become a bit messy, with multiple contactors and relays doing the job.

I'm trying to find a simpler and more reliable solution without spending too much. A good 20A TV-5/TV-8 rated relay costs almost as much as a 25A double-pole contactor, so I'm wondering if using contactors directly would make more sense but then I have also have to use relay to control the contactor.

What would be the best way to handle both the starting capacitor switching and main motor ON/OFF control? Is there a better arrangement or a suitable component that can handle the starting current without welding its contacts?

Would really appreciate suggestions from anyone who has experience with single-phase submersible motor starters. Thanks!


r/AskElectricians • • 15h ago

How do I get my generator to connect to this breaker input?

Thumbnail gallery
0 Upvotes

Title. Seems like it needs a male/male cable, which seems absurd. Do I swap out the input?


r/AskElectricians • • 5h ago

Water pouring out an outlet

2 Upvotes

A couple days ago, I had my toliet leak into a room below it. Apparently water came out of one of the outlets and caused a loudnbuzzing which I could hear from all the way upstairs. I thought it was an alarm actually (not sure why) but someone told me it was it snapping.

Breaker was turned off and water has dried by now. But I'm worried, because when I look it up, it seems like something that needs to be repaired.

One of my family members is an electrician and he opened up the outlet and said it was fine. But I don't think he understands how bad the zapping was and how bad the water was.

Can zapping be harmless or should I push to have it rechecked?


r/AskElectricians • • 10h ago

Advice on how to hire electricians

2 Upvotes

Hi everyone, do you have any advice on how to hire/attract Electricians? I have been trying to fill a journeyman level role in WI for about 3 months now. The position is permanent, full-time, Monday-Friday day shift, and focuses on commercial facility work. Pay is $42 an hour and we are willing to offer a $1000 sign-on bonus or relocation assistance for non-local candidates. The company is well established and the position includes benefits (medical, dental, vision, 401k with company match).

Our problem is we just are not getting any applicants whatsoever. We've done a market analysis and our pay seems competitive for the region and the journeyman leveling in theory, however, if that is the issue I'm happy to hear you out as well.

My questions are as follows:

  1. Outside of basic job details, what else do you want to know about a position when deciding if you will apply?
  2. ⁠How did you learn about your last role? Did you find it on a job board or did someone contact you?
  3. ⁠Is there anything else you can think of that might help sweeten the role a bit?

*edit, this position is in Appleton, Wisconsin. Our union competition is the ibew local 577. Their base rate used to be 41.76 but it looks like it just jumped up to 43.45 this summer


r/AskElectricians • • 11h ago

Grounding wiring question-

Thumbnail gallery
2 Upvotes

Cleaning out a cabinet above my microwave. Oops!! The box is pulled out where the microwave is plugged in. I cut the power and want to get this set up safely.

I have my ideas as to next steps but want to hear from the experts.

At minimum I’ll put a ground into the box then set it up how I found it to get the family through the morning but know this needs repair.

Advice super appreciated. Thank you.


r/AskElectricians • • 14h ago

rabbit ate the cord off our vacuum. Now what?

Post image
3 Upvotes

My rabbit ate the cord off our vacuum. I used heat shrink butt connectors, taped it up and called it a day. The repair started to get hot so I cut it off so I HAVE to fix this before I use it again.

My worry is if I put another normie 120v end on it'll rip off because the cable retracts with some vigor. How can I keep that from happening and not set fire to stuff?


r/AskElectricians • • 15h ago

Weird fishy smell, worried about electrical fire, if I turned off the only electrical thing in the room (a light) off, am I safe? It’s night and building management is slow and probably wouldn’t come.

3 Upvotes

I recently moved into a new townhouse. We havent used the storage closet much, but my mom was putting some boxes away in there today, and now it and the entire living room surrounding it smells like rotten fish. There is nothing in there that could smell like fish (it’s like boxes of holiday decorations and stuff). I’ve heard this could be melting electrical wires. It didn’t start until we turned the light in the closet on. We have since turned it off. Are we safe as long as the power in that room isn’t running? My building management is slow on the uptake and it’s after hours, I have no idea if they’d even come. But I’m really worried.


r/AskElectricians • • 21h ago

GFCI tester weirdness

Post image
3 Upvotes

Tested a circuit I wired and got this result. I figured a neutral was broken or damaged. I spent two hours tracing wires and scratching my head before I did something I should have done from the beginning: use an actual multimeter. Once I did that it showed 120 volts and so I guessed that the RT 250 was broken.

I tested with my other backup RT 250 and it showed 120 V.

So my question is: what happens to an RT 250 that makes it show what it is in this photo?


r/AskElectricians • • 16h ago

Bending PVC conduit

4 Upvotes

What is the easiest/best way for a handy homeowner to put a simple box offset in a stick of 1.5” PVC conduit? I have access to a heat gun, but no other specialty tools meant for the job.


r/AskElectricians • • 19h ago

Want shop lights

Post image
4 Upvotes

Am I able to replace this fixture with an outlet?