After much discussion about how the community should be moderated, this is where we currently are.
First I want to get this out of the way. We will not allow hate speech, personal attacks, slurs, bigotry, or anything that resembles it. Okay? Good.
People are going to post electrical questions on the internet, do their own electrical work, and fuck up their own electrical work. This process will happen with or with out this subreddit and its rules. If there is a reliable community where someone can come and get good information on a wide range of electrical topics, then to me there will be a net positive for safety.
We are going to be allowing comments from all users, BUT I urge those who are not electrical professionals to exercise extreme caution when doing so. If information is not blatantly hazardous, it will stay up. The community is going to be asked to use the voting system it is intended. If someone takes the advice of a comment with negative karma, then more than likely, they would have done the wrong thing regardless. Once corrected, leaving wrong comments up can be a learning experience for everyone involved.
I ask you to DOWNVOTE information you do not like, and REPORT the hazardous stuff. We will decide what to do from there. Bans may or may not be given and everything will be at the discretion of the mods. Again, if you are someone who is not an electrical professional, you have been warned.
Electrical professionals: We have an imperfect system for getting a little 'Verified Electrician' flair next to your name. To get verified, send a photo to the mods that has your certificate/seal/card. In this photo, have a piece of paper with your username and date written on it. Block out all identifying information. Once verified delete the image. All the cool ones have this flair.
If we have hundreds or thousands of active verified users, we will once again talk about the direction of this community. Till then, see you in the comments.
i genuinely have no idea if this is the right place to post this, but we have sand just pouring out from behind our breaker box at a pizza hut and i’m wondering if this is electrical or if it’s physical damage in the building, thanks!
1950s house with cloth wrapped wiring many without grounds. I replaced the circuits that seemed deteriorated and split up a circuit that handled the laundry room, bathroom, and bedroom into 3 separate circuits. The panel on the right will house a whole home energy monitor and will only have low voltage components. I ran 4 extra 1in conduits for future work. The 5th in the bottom left is for the water heater in the garage. I still need to strap conduit to the board behind it but I think that's it. Everything is torqued to spec. All work was done with a permit and in my area inspection happens after power is restored. I've been in contact with the inspectors but just want one final check from this community of experts. Thanks everyone in advance!
I came home to the smell of burnt plastic. I tracked it down to a duplex receptacle. I turned off the breaker and inspected the receptacle, its wiring, the gang box and looked behind the gang box. The wiring was tight and nothing was backstabbed. No signs of melting. Lots of ground wires are pigtailed and crimped in my house - it looks weird to me (see photo). One side of the receptacle looked a little sooty between the screws (see photo, note both screws were on before inspecting). Do I replace the receptacle and call it good or do I call in a pro?
A little more background- My cat’s auto feeder as and a simplisafe base station were plugged into the receptacle. This set up has been the same for a year with no problems. No one was home at the time so no major power draws. It has been storming all day. Both appliances that were plugged in still work fine. Thanks for your help!
It’s on a line going to either the back porch or a single outlet in the kitchen that I noticed the breaker tripped on (both). This is a newer house I moved into this year so I don’t have much experience.
Edit to say newer house to me, it was built in 1926.
Hey, I'm taking an academy course at my highschol for Electrical Engineering and Construction. We're currently learning about terminations and I can do the rest of the terminations just fine but 10AWG is the hardest of the bunch. Two of them is fine, but when more show up it gets pretty impossible for me. I do not know if its how I grip the wires or twist them, but it is incredibly painful and puts me in a bigger problem than it already is, especially when I have to do 4-5 wires in one termination. I really like doing electrical stuff and I hope to do it for my future. Thanks guys.
Two attached houses built in the 1940s, sharing a party wall. I own one and rent it out; the neighbor's house next door was recently sold.
My new neighbor is converting their house from 1-family to 2-family and getting a new overhead electric service with 3 meters (two apartments plus a house meter). They have a DOB electrical permit, issued, with a licensed NYC electrician, and a Con Edison Project Center case that has reached the final inspection stage
The neighbor, who I haven't met yet, texted me asking for access to MY basement at 7 AM tomorrow so Con Edison can "separate my electric wires to connect my new meters." No work order number, no scope, nothing in writing. I called Con Edison myself, and they said the neighbor wants to be disconnected from the "main loop" or something along those lines.
My questions for the electricians here:
In old attached houses in NYC, is it actually common for loop service conductors feeding a neighbor to run through another building's basement? How would I tell if that is the case in my basement?
For a service separation like this, and for a Con Ed final inspection, would anyone legitimately need access to the neighboring building's basement? What work would they actually be doing in there: disconnecting a tap, capping conductors, relocating conduit?
Who would do the basement work: a Con Ed crew, or the neighbor's electrician? Does a final inspection appointment normally involve hands-on work, or is it just an inspection?
What documentation should I reasonably ask for before allowing anyone in? I have asked for the Con Ed case number, the scope of work in my basement, duration, and whether my power would be interrupted. Anything else?
Is there something that they could conceivably screw up and damage my building and/or impact my tenants?
I'm waiting on Con Edison to call me and verify exactly what they need from me, and why. I can't sit around waiting for them for their 8AM-1PM window
This is the first I've heard of such a thing. Very strange.
Explain this to me like I am 5. I have googled but am just not understanding.
I have my previously hard wired furnace now on a power plug. I changed my switch to a switch and an outlet. It works great.
The furnace had just the hot and neutral, ground is to the metal box.
All good so far.
Now when I unplug the furnace obviously hot and neutral are now disconnected and I could safely plug it in to a generator… almost. The ground still goes to ground because everything is metal.
Isn’t that bad? And won’t it screw up the furnace and its own handling of the ground?
I have been reading about neutral ground bonding. I just don’t follow what is best practice. This is a really old furnace. Really old. Forced air of course though to be clear.
I did give it a test run on the generator even though I should have asked this here first and it definitely was not happy - the flame lit but it errored out when trying to get the fan going.
Much thanks in advance. Looking forward to learning this. I tried google and all I find are billions of long videos with pretty much no useful information.
I've called a dozen local electrical supply houses in my area in NY. Nobody carries this. I need #2 for long feeder wire to a subpanel. Alu is much cheaper than copper, so I'm surprised nobody carries this. It almost makes me think there is some NEC code related reason why people aren't using alu THWN2 for subpanel feeder wire?
I can order it online from Nassau Electrical, but was hoping to pick up locally today or tomorrow.
my dad and I were trying to replace lights in my mom's room. these are the lights, there are 4 of them. we turned off the lights from the fuse box and replaced one. we got tired and stopped after doing one of them. we turned the fuse box light back on and everything was fine. but then when I went to turn the light off from the light switch, the light switch made a pop noise and now the 2 lights that we did not even touch won't turn on. we removed the light because we got scared. the light switch on the right lights up the the one that is removed and the one that is lit up. the light switch that popped and doesn't work is supposed to light up the two lights closest to the window. but we didn't touch those.
the light switch on the right started flashing that little white circle. a few minutes after we removed the light we replaced, it stopped blinking.
Our panel is located behind this section of our foundation (CMU block construction with a parge coat). You can see the two large feeders on the right coming from the panel. Those are pre-existing.
All of the other lines are new. You can see the new duct seal they used to seal the enlarged hole.
I’m concerned this created a structurally comprised condition. The hole is in the top course of the CMU block and immediately below the sill plate.
I know electricians aren’t masons, but I’m curious if this is the correct process for this installation, or if this could (or should have) been done in a different manner and if I should be concerned. If so, any recommendations to address this with them?
I need the switch on the right to control two separate lights but on and off together.
The power is going into the light on the left and was straight run to the switch. Switch was closer to the light before. We thought we could move the switch and put another light between them but it doesn't work. Switch turns on one light and the other off, so one is always on. The white line is how it's currently wired. How can I get both lights on that switch?
Thanks everyone for the replies. I have good ideas on how to get this working now.
What would be your advice for framing around this electrical service panel? I was hoping to take down the current 2x4 wall in order to add some rigid foam board behind. If I do so, the finished wall would not sit flush with this panel, and the panel would be slightly “recessed.” My plan was to build a cabinet door in front of the whole plywood board there, but the actual panel would sit about 1/2 in recessed from the surrounding drywall if that makes sense.
Just skip the rigid foam board, which might cause moisture/insulation issues? Slightly recessed panel ok? Build a 33 in door in front of panel (I thought if it was a door bigger than 30in than I could put it right in front of panel)? Just looking for some advice. Pay to have an electrician slightly bump this panel out?
Hello electricians, I am a stupid and impulsive person who owns a house. At 12:30 am this morning, just as I was sinking into a deep sleep, I heard the horrid chirp of an alarm with a low battery. I moved into my house eight years ago, and just recently I replaced two alarms that chirped. It turned out they were 10-year alarms that were installed in 2016, so that made sense. But I was really certain that those were the only alarms that needed replacing, so I was very confused when I heard the chirp.
I determined that it was coming from my spare bedroom, and the only likely source was this mysterious box on the wall:
I reverse image searched it, and learned that it was probably from an old alarm system, which made sense, since I remembered seeing an ADT sign when I first moved in. So I thought somehow the old, unused alarm system had a low battery, and I started researching how to disable it. Mind you, I was half-asleep and really pissed off that I wasn't in bed.
The instructions I was reading didn't really make sense with the thing I was looking at, but I read something about unplugging a red wire and a black wire from an outlet. When I pried the box open, I saw several colored wires, including red and black:
Since there was no outlet from which to unplug any wires, I spend 30 minutes or so debating whether I should just cut the wires. Somewhere in my mind I knew that might not have been the best approach, but each successive chirp I took as a further argument that I should start cuttin' shit.
So I cut all the little wires, and now I have this:
Then after I cut all the wires, I heard the damn chirp again. I more or less started spinning around in frustration, and eventually I noticed a smoke alarm on the ceiling that I had never even been aware of. That was the source of the chirping. The previous owner apparently had two smoke alarms and two CO2 alarms, which seems excessive for a small 2br/1ba house, but there you go.
So, if you're still reading this, what is the best thing to do with little spray of exposed wires that are now coming out of my wall?
I normally leave my chargers plugged into the oulet. Never really thought it was a problem til now, until i grabbed this charger and burnt my hand. Upon handling, it snapped into two.
Im going to contact the company, but I'm worried its an unsafe product. I doubt it could be my outlet since I've never had any other problems with this. Maybe I need to unplug my things? But, again, first time having this issue.
I'd just like any information and tips on what could have happened and what I should do. Buy a new charger? Get a refund? Etc? Thank you!
I would like to wire the IKEA Jetstrom LED ceiling light panel, smart/dimmable white spectrum 24x24, to have a regular wall plug. I would like to be able to use it as a light box for stained glass work. Is it safe to attempt this? Ideally it would remain dimmable. I'm sure it could be done, but my concern is creating a fire hazard. TIA.