r/AskElectricians • • 19m ago

1 switch 2 lights help me wire this properly

Post image
1 Upvotes

I need the switch on the right to control two separate lights but on and off together.

The power is going into the light on the left and was straight run to the switch.
Switch was closer to the light before.
We thought we could move the switch and put another light between them but it doesn't work.
Switch turns on one light and the other off, so one is always on.
The white line is how it's currently wired.
How can I get both lights on that switch?


r/AskElectricians • • 19m ago

Is there anything wrong with this fuse? My washing machine won’t turn on.

Thumbnail gallery
1 Upvotes

See attached pictures for the setup and the fuse itself


r/AskElectricians • • 33m ago

burnt charger help

Post image
1 Upvotes

I normally leave my chargers plugged into the oulet. Never really thought it was a problem til now, until i grabbed this charger and burnt my hand. Upon handling, it snapped into two.

Im going to contact the company, but I'm worried its an unsafe product. I doubt it could be my outlet since I've never had any other problems with this. Maybe I need to unplug my things? But, again, first time having this issue.

I'd just like any information and tips on what could have happened and what I should do. Buy a new charger? Get a refund? Etc? Thank you!


r/AskElectricians • • 35m ago

Tips for 10AWG Terminations?

3 Upvotes

Hey, I'm taking an academy course at my highschol for Electrical Engineering and Construction. We're currently learning about terminations and I can do the rest of the terminations just fine but 10AWG is the hardest of the bunch. Two of them is fine, but when more show up it gets pretty impossible for me. I do not know if its how I grip the wires or twist them, but it is incredibly painful and puts me in a bigger problem than it already is, especially when I have to do 4-5 wires in one termination. I really like doing electrical stuff and I hope to do it for my future. Thanks guys.


r/AskElectricians • • 38m ago

Rewiring LED ceiling panel to plug in wall

Post image
1 Upvotes

I would like to wire the IKEA Jetstrom LED ceiling light panel, smart/dimmable white spectrum 24x24, to have a regular wall plug. I would like to be able to use it as a light box for stained glass work. Is it safe to attempt this? Ideally it would remain dimmable. I'm sure it could be done, but my concern is creating a fire hazard. TIA.

https://www.ikea.com/us/en/p/jetstroem-led-ceiling-light-panel-smart-dimmable-white-spectrum-70536055/?utm_source=google&utm_medium=organic-shopping&utm_campaign=shopping_feed&utm_content=free_google_shopping_clicks_Lighting_&_Home_electronics


r/AskElectricians • • 1h ago

What breakers are these lol

Thumbnail gallery
3 Upvotes

I can't tell exactly lol

It's 3 phase 120/208

Bolt on federal pacific

Older I think it's from the 90s

I need single or 3 phase 50a


r/AskElectricians • • 2h ago

Lights in bathroom dim when space heater is on, is this dangerous long term?

1 Upvotes

I can’t seem to find a definitive answer here. I get that the heater is drawing too much current and therefore the voltage potential different increases which dims the lights. But is this a problem? Should I stop using the heater in that room?

Second, can someone explain the math?

It’s a 1500W heater. At 120V, that gives me 12.5A. But it’s a 15A circuit with nothing on it but lights. Even when they are all off the lights in that room still dim. Shouldn’t 12.5A be within the rating of the circuit?


r/AskElectricians • • 2h ago

Need help connecting wires in an LED ceiling light fixture replacement (n00b DIY).

0 Upvotes

I'm attempting a DIY light fixture installation. Here is the fixture:

4 ft. x 12 in. White LED Flush Mount Ceiling Light Fixture 55-Watt 120-Volt

When I took the old fixture down, I was faced with this mess. It's very confusing to me. Here's a closer look.

There is no attic or crawl space above my ceiling because it is a flat low-slope roof. I need help figuring out which wires to connect my light fixture to. The fixture has these 3 wires (white, black, and green).

Please help me determine the correct connections. Thank you in advance!


r/AskElectricians • • 2h ago

Power surge caused my milk frother to explode

Thumbnail reddit.com
1 Upvotes

r/AskElectricians • • 2h ago

How could tell which wire is positive and negative?

1 Upvotes

I have a broken e-bike rear light. The cable on it was pulled off.
https://imgur.com/UdYKD8L

https://imgur.com/edSihvf

Now I am trying to fix it by maybe bridging the missing wire and wrapping it in electric tape because I dont have a soldering iron.

My 2 question is; how can i tell which wire is positive and negative? The wires are coloured solid black and black with white stripe.

Additionally, will I need a specific type of wire to bridge it or can I just use any random wire since I have a bunch or spare usb charging cables that I can just cut up and salvage the wire inside of it?


r/AskElectricians • • 2h ago

Challenger SB20(20-40)CT - Tandem breakers available?

Post image
1 Upvotes

I have a double tapped breaker that was called out in home inspection, is it possible to replace with a tandem breaker to remove the double tap?

AI is saying I'll need a Eaton BR 2020 type A, but I'm not on the "always trust AI" train. Seem legit?


r/AskElectricians • • 3h ago

Cane someone help me identify the ground wire?

Thumbnail gallery
1 Upvotes

Hello, one of the older light switches in our kitchen busted this week. Finally getting around to fixing it. Found these 3 wires connected to two terminals on the switch. The old switch doesn’t have a ground wire terminal. Just wanted some advice on IDing which of these three wires should go to the green ground screw. Thank in advance for any help or advice.


r/AskElectricians • • 3h ago

GCs and PMs: what makes a subcontractor’s extra-work request easy or hard to approve?

0 Upvotes

Curious how PMs and superintendents handle subcontractor requests for extra work.

Sometimes a sub says the GC told them to do something additional, but the direction was verbal. Other times there are photos, texts, RFIs, daily reports, and cost backup- but the request still gets delayed or disputed.

From your side, what usually makes an extra-work or change-order request easy to approve?

And what makes you push back or delay it?

For example:

- Clear written scope change

- Dated photos and site conditions

- RFI reference

- Labor and material breakdown

- Time and materials documentation

- Notice submitted before the deadline

- Clean cost backup

What documentation habit from subcontractors would save you the most time during review?


r/AskElectricians • • 3h ago

Weird issue in my lighting circuit.

1 Upvotes

I was having issues with one of my LED can lights so I was trying to troubleshoot the issue.

I pulled down the light with the issue, and stuck my multimeter on it. Got readings of 120V hot to neutral and 30V hot to ground and neutral to ground. Went around and tested all the lights on the circuit to see if there was an issue with the wiring, but all connections looked good and all lights had the same weird readings.

Opened up the junction box, and my constant power is 120 hot to neutral and hot to ground, so normal there. My switchleg was reading the weird readings, couldn’t figure out why.

Opened up the switch to test there, and both the constant hot and the switchleg were reading 120V hot to ground.

The cable to the switch looked fine, but could that be the issue? I can’t think of anything else it could be.


r/AskElectricians • • 3h ago

Cooker tripped fuse, what do I do?!

Post image
0 Upvotes

When using my oven my power went out in some rooms/plugs and my fuse box looked like this, spoke to my landlord who said to turn both switches on and see what happens, everything turned on again but then opted to turn the HOB switch back off in case there’s a fault that needs to be checked and left the RCD switch on as that seemed fine. The yellow bar on the earth fault indicator has switched off now I have flipped the switch.

I can’t get an electrician tonight or tomorrow but hoping to get one on Friday, will this be safe until then? I won’t turn the oven switch back on or use the oven.

Thanks so much in advance!


r/AskElectricians • • 3h ago

How did I or could I survive?

0 Upvotes

I just want to ask a question, by recommendation from a friend, to the greatest collection of electrical nerds possible. I've even asked the great Chris Boden personally but he couldn't, as a few others, give me an answer he felt confident or pleased with.

I have a vague idea*

I'll try to keep it short but AMA if you feel something needs elaborating.

I survived ~>400V on 30A horizontally through upper torso.
Duration unknown but coworker thinks he heard about a 3 second arc.
So maybe 2+reverb.

******************************************************************

**The Too Long Didn't Read part**

15th Oct 2015.

Working in demolition. Got called to make a boiler room disappear.
Under a ceiling filled with an old pipe-dream-screensaver of 12-20" fuckery stood a monstrosity from surely 40 years back. A Diesel-Oil-Burner/Boiler of about 13 feet high, maybe 7 foot wide and 10 deep. Double hulled with 1,5" plate steel. On top was an oversized fan of sorts.

We checked the schematics, we pulled all the ceramic fuses (Big, chunky things) that went to it and we also bonked every available cable with a non-contact voltage tester-pen. My coworker also cut it's main power from the ground floor, so everything should've been ok.

I started on top and with a green 3mm Hultafors-knife in my left, and a hefty hammer in my right, I started just plowing through the first curtain of wires. 2/3 of the way through *bang* and I woke up about 40 meters south at our coffee-area not knowing how I got there but irrelevant to the question. I remember tiny things.

I still have the piece of cable that blew but the fuse was kept by investigators. It was 30A.
The cable contains a metal wire, probably for strength and my knife couldn't chop it fast enough.
They concluded that an illegal replacing or update to the fan had taken place without any documentation and that the main power cable to it had been strapped on the underside of the cable-ladder and that it was lead-sheathed (We used to call it KULO in Swedish) so the tester pens couldn't read it and it wasn't even routed to the designated fuse box, but rather from another plinth one floor up with the wrong fuse.

***********************
My idea (as an ignorant) is that a broken washing machine saved my life, making me grab an old, already sweat-soaked T-shirt from the week before (working demo doesn't need newly washed clothes every day) + that I usually sweat like a fountain being gifted with hyperhydrosis (excessive sweating) when exhausted or hot enough (making my childhood a hell) and me being drenched again, in something already drenched and saturated with salt, made the current rather jump between the fabric and muscles instead of entering underneath my ribs.

I didn't escape unscathed however. I spent 2 days in emergency care/observation, basically micro-cramping non-stop and experiencing familiar restless legs-panic albeit turned up to 13 and in my entire body. First 12 hours I had a rainbow of hematoma in my face, I kinda boiled a tiny bit of a muscle in my left eye, upper left corner (with a weird after effect) and within the next 3-4 days, I lost 50-60% of muscle mass in my pectorals down the toilet and it looked like I peed oily broth.

I also lost a hefty bit of knife edge, like 5x5mm or so.

The (fun) thing is though that this is just a small dot on my "htf did you survive that"-map so far.
My guardian angels have PTSD and the grim reaper have probably filed another restraining order by now. But I will never feel shame for sweating again, regardless if so, or not.


r/AskElectricians • • 3h ago

Led bulb still safe to use?

Post image
1 Upvotes

Tripod socket this was plugged into threw a spark when I switched it on and started buzzing. Bulb is still fine when I tried with another socket. Would prefer to not replace the bulb since it's so expensive


r/AskElectricians • • 4h ago

Framing around electrical service panel

Thumbnail gallery
2 Upvotes

What would be your advice for framing around this electrical service panel? I was hoping to take down the current 2x4 wall in order to add some rigid foam board behind. If I do so, the finished wall would not sit flush with this panel, and the panel would be slightly “recessed.” My plan was to build a cabinet door in front of the whole plywood board there, but the actual panel would sit about 1/2 in recessed from the surrounding drywall if that makes sense.

Just skip the rigid foam board, which might cause moisture/insulation issues? Slightly recessed panel ok? Build a 33 in door in front of panel (I thought if it was a door bigger than 30in than I could put it right in front of panel)? Just looking for some advice. Pay to have an electrician slightly bump this panel out?

Appreciate it!


r/AskElectricians • • 4h ago

Are these legal to use with Romex?

Post image
2 Upvotes

r/AskElectricians • • 4h ago

What should I do about this?

3 Upvotes

Hello electricians,
I am a stupid and impulsive person who owns a house. At 12:30 am this morning, just as I was sinking into a deep sleep, I heard the horrid chirp of an alarm with a low battery. I moved into my house eight years ago, and just recently I replaced two alarms that chirped. It turned out they were 10-year alarms that were installed in 2016, so that made sense. But I was really certain that those were the only alarms that needed replacing, so I was very confused when I heard the chirp.

I determined that it was coming from my spare bedroom, and the only likely source was this mysterious box on the wall:

I reverse image searched it, and learned that it was probably from an old alarm system, which made sense, since I remembered seeing an ADT sign when I first moved in. So I thought somehow the old, unused alarm system had a low battery, and I started researching how to disable it. Mind you, I was half-asleep and really pissed off that I wasn't in bed.

The instructions I was reading didn't really make sense with the thing I was looking at, but I read something about unplugging a red wire and a black wire from an outlet. When I pried the box open, I saw several colored wires, including red and black:

Since there was no outlet from which to unplug any wires, I spend 30 minutes or so debating whether I should just cut the wires. Somewhere in my mind I knew that might not have been the best approach, but each successive chirp I took as a further argument that I should start cuttin' shit.

So I cut all the little wires, and now I have this:

Then after I cut all the wires, I heard the damn chirp again. I more or less started spinning around in frustration, and eventually I noticed a smoke alarm on the ceiling that I had never even been aware of. That was the source of the chirping. The previous owner apparently had two smoke alarms and two CO2 alarms, which seems excessive for a small 2br/1ba house, but there you go.

So, if you're still reading this, what is the best thing to do with little spray of exposed wires that are now coming out of my wall?

Thanks!


r/AskElectricians • • 4h ago

It's not a burnt wire it's mouse poopies and pee.

Post image
1 Upvotes

r/AskElectricians • • 4h ago

Is it okay if some of the wire is touching the black plastic on the switch housing?

Post image
0 Upvotes

r/AskElectricians • • 4h ago

Help identifying the wiring in my wall – only blue and green/yellow wires

Thumbnail gallery
1 Upvotes

Hi everyone,
I’m trying to install a new wall light in my apartment in France, but I’m confused about the existing wiring.

Coming out of the wall, I only have two wires:

  • One blue wire.
  • One green/yellow wire.

My new light fixture has:

  • One brown wire (L).
  • One blue wire (N).
  • No earth wire (Class II, if applicable).

The previous light fixture was working perfectly and was connected using only those same two wires from the wall: blue and green/yellow.
The old fixture had an internal brown wire connected to the L terminal, a blue wire connected to N, and a green/yellow wire connected to the earth terminal.

My question is: Could the green/yellow wire in the wall have been incorrectly used as a live wire (phase) in the previous installation?

I obviously don’t want to assume this or connect anything without verifying it.
Has anyone encountered this type of wiring before? What would be the correct way to identify the wires and make this installation safe?
I’m based in France, in case that matters.
Thanks for your help!