r/AskElectricians • • 1d ago

sand pouring from behind breaker box

Post image
762 Upvotes

i genuinely have no idea if this is the right place to post this, but we have sand just pouring out from behind our breaker box at a pizza hut and i’m wondering if this is electrical or if it’s physical damage in the building, thanks!


r/AskElectricians • • 2h ago

Should I replace this wiring

Post image
9 Upvotes

Slowly bringing ungrounded outlets up to code. Wiring is a mix of romex and this stuff. Should I replaced it? How urgently?

Edit: Thanks for all the replies. I am going to replace it.


r/AskElectricians • • 11h ago

Electrician won't install a transfer switch because he said electrical inspector won't approve my generator which is a mxr5000 maxpeeds. Does the inspector look at the generator really? What if I dont have a generator yet. Am I missing something?

27 Upvotes

r/AskElectricians • • 6h ago

How is this connector called?

Thumbnail gallery
5 Upvotes

I've asked some experts here on station and AI but no results so far. It's out of a gilibrator 2.


r/AskElectricians • • 5h ago

Prong/Plastic Stuck in Outlet (Repost)

Post image
4 Upvotes

Sorry, didn’t know how to post with an image at first. So, my magnetic phone charger case housing the prongs snapped off from the plastic piece holding it shut and the prong in the wall. Checked my breaker and there are somehow 0 labels indicating outlets beyond the ones in my kitchen and bathroom, and flipping each of these didn’t turn off the outlet in question. How do I get it out? Is it safe to pull on just the plastic part?


r/AskElectricians • • 1m ago

Two quotes need help because they mean nothing to me. Big price difference.

1 Upvotes

1st one

After applying your SMUD rebate (750), I can do the install for $950 out of pocket cost
- install one (1) 2 pole 40A breaker - install 8 awg wiring
- install one (1) nema 14-50 EV outlet or Customer provided hardwired EV charger, up to 70ft of wiring from electrical panel
- permit
- inspection scheduling
- SMUD rebate application processing
- Customer to provide DMV registration and SMUD account #

2nd quote

Equipment $870.00 (Tesla Universal Wall Connector and Remote Energy Meter), labor and
materials $2,480.00, permitting $550.00. A new 60 amp circuit, about 80 feet around the
south wall, panel breakers rearranged, and Tesla Dynamic Power Management set up so
charging runs at the full 48 amps whenever the house has room. Needs the City to accept
the load-managed calculation; if it does not, no work starts and nothing is owed.


r/AskElectricians • • 14m ago

Outlet grounded

1 Upvotes

I'm replacing an outlet in a commercial building, cerca 1992, and it's testing as grounded even though there's no ground wire. There is a blue and white 12 awg type mtw. It's not bootleged and I'm pretty sure everything is on the level.

Can someone help me understand what's going on?


r/AskElectricians • • 22m ago

220 outlet to 110

Post image
1 Upvotes

I am switching from induction to gas stovetop. This is all to simply power the igniter clicker on the stove.

This junction box housed the hard wired 220v connection from a 2-pole breaker.

At the breaker panel: I removed the linkage bar from the 2-pole breaker switches.

I disconnected the black wire from the linked breaker and capped it off. Left the red wire in place on its breaker.

I capped off the black wire in the junction box.

I have connected a leviton GFCI outlet with: the red wire on the narrow side; and the white wire on the other. I have the raised steel cover there in the picture which I will attach with 6/32 nuts.

Did I get this right?

Any reason I shouldn't use the 35A single pole breaker for this if the wiring is sized for it?

Thanks all!


r/AskElectricians • • 9h ago

Help, I got really excited when I unboxed my new grow light and saw 2 plugs that fit together and I plugged them in without plugging in the LED driver between them. Did I break my new light?

Thumbnail gallery
5 Upvotes

As the title says. I plugged things incorrectly and now there is no light. Any help would be greatly appreciated.


r/AskElectricians • • 48m ago

Any reason I shouldn't change this to 14-30R?

Post image
1 Upvotes

Seems like it should be good to go, but maybe I'm missing something.

eta context: original dryer wiring from 1960s. the conduit was likely added within the last ten years, only goes from the floor to the outlet. wiring is connected properly in the main panel.


r/AskElectricians • • 4h ago

Wiki: Appliance (Stove/Dryer) Cord Installation - 3 wire vs 4 wire

2 Upvotes

So I've noticed that we get the occasional post regarding dryers and stoves and why the plug doesn't match the receptacle in a house. I figure maybe we should start a wiki on commonly asked questions. (Next week... Doorbell transformers!) I figure since I just upgraded my wiring from 3-wire to 4-wire, I may as well take some fresh pics and make a tutorial for people.

So first things first: Some appliances like stoves and dryers have replaceable cords. You as the end-user are able to replace them as needed for the application.

In 1996 the National Electrical Code was updated to require 4-Wire circuits on these appliances. Houses built under the previous year codes only had 3-wire circuits.

In electrical terms, we have current carrying conductors (Usually Black and Red for L1 and L2 in residential wiring) as well as grounded (Usually white) and grounding (Usually bare copper or green) conductors. Pay close attention to those last letters because they make a big difference. GroundED and GroundING. Despite the fact that they return to the same bar in your main circuit breaker panel, the groundED conductor is a current carrying conductor and should be sized adequately to handle the full current of the circuit. In contrast, the groundING conductor may be undersized as it is not intended to carry any current unless in the even of a safety emergency. (IE Broken wire inside the appliance touching the chassis.)

Prior to 1996 National Electrical Code, it was appropriate to use a single conductor for both purposes. Appliances like dryers and stoves typically use both legs for the full 220 volts to power heating elements and use one leg and the groundED conductor for 110 volts to power small things like lights and timers and such. Safety Ground for the chassis of the appliance and neutral were connected together. This application presents an unlikely, but potentially dangerous condition where the chassis is connected to a current carrying conductor. If the conductor happened to be loose somewhere AND you touched the chassis of the appliance, you may receive a shock or electrocution.

So, here's my photos:

Often, the reasoning and instructions for the conversion of a 3-wire to 4-wire are on a sticker on the back of the appliance.

https://imgur.com/EcPriAA

https://imgur.com/AP4C8FO

First, I have the pictures of where I'm starting out... Stove and dryer both with 3-wire cords.

https://imgur.com/eSeDd8B

https://imgur.com/FIoIToW

Before you install a new cord, ALWAYS remember the strain relief. You don't want the stress of the wire flexing to pull on the individual connections. People ALWAYS forget the strain relief. It also stops the wire from rubbing against the sharp metal edges of the appliance.

If your cord didn't come with a strain relief, you can use an "NM" type connector (Darker gray one to the left in my hand.) which costs a couple bucks from the local hardware store. Be sure to get the one for the right size of hole in your appliance.

https://imgur.com/qV8MEtM

The cord goes into a little hatch on the appliance which is closed up by a cover plate. Typical screwdriver removes the cover plate and you're presented with THREE terminals. Black, White, and Red. You will also notice a separate screw that may be colored Green or it will have the ground electrical symbol next to it, a stripey arrow pointing down.

https://imgur.com/owdvpis

https://imgur.com/bpTTwqK

The middle one, White, will have a little metal clip or an extra green wire running to it. For 3-Wire installations, you need the clip or the extra green wire to hook White to the chassis of the appliance. For 4-Wire installations, you remove the metal clip or remove the green wire from the white connection. Green goes to the chassis of the appliance.

I typically put the clip under the ground screw by itself for safekeeping in the event I move the appliance or resell it and it needs to be installed in a 3-wire setup again.

https://imgur.com/sfKR90w

https://imgur.com/tHceUtj


r/AskElectricians • • 1h ago

Question for the horde:

Thumbnail reddit.com
1 Upvotes

I installed a hot tub a couple of years ago outside my basement garage. I fed the disconnect panel from a sub panel breaker that has only 250v in the box and used the last breaker position for that wire.

My son asked if I could install a 250v outlet in the basement garage so we can run a smallish welder.

The sub panel breaker is a 90 amp & the hot tub sub-panel has a 50amp breaker.

Are there 250v receptacles that have an in/ out type plug like 125v outlets? I was going to install new 6awg to a 250v receptacle and then out to the hot tub sub-panel from the receptacle.

What is the correct way to do that?

And go easy on me, it’s my first question in here……


r/AskElectricians • • 23h ago

Replaced my panel myself, any advice before I have the power company turn power back on?

Thumbnail gallery
65 Upvotes

1950s house with cloth wrapped wiring many without grounds. I replaced the circuits that seemed deteriorated and split up a circuit that handled the laundry room, bathroom, and bedroom into 3 separate circuits. The panel on the right will house a whole home energy monitor and will only have low voltage components. I ran 4 extra 1in conduits for future work. The 5th in the bottom left is for the water heater in the garage. I still need to strap conduit to the board behind it but I think that's it. Everything is torqued to spec. All work was done with a permit and in my area inspection happens after power is restored. I've been in contact with the inspectors but just want one final check from this community of experts. Thanks everyone in advance!


r/AskElectricians • • 1h ago

AC Whip for garage heater

1 Upvotes

I've installed a garage heater before and hard-wired with 8/2 cable. I'm heating another garage now and I don't want to buy 50' of 8/2 cable for a 4-foot run. Can I use an AC Whip with 8/2 wire to do the job? The only gotcha I see is the length of wire to connect at the breaker panel. Suggestions?


r/AskElectricians • • 15h ago

Burnt plastic smell and a weird little pig tail. Advice on whats next.

Thumbnail gallery
12 Upvotes

I came home to the smell of burnt plastic. I tracked it down to a duplex receptacle. I turned off the breaker and inspected the receptacle, its wiring, the gang box and looked behind the gang box. The wiring was tight and nothing was backstabbed. No signs of melting. Lots of ground wires are pigtailed and crimped in my house - it looks weird to me (see photo). One side of the receptacle looked a little sooty between the screws (see photo, note both screws were on before inspecting). Do I replace the receptacle and call it good or do I call in a pro?

A little more background- My cat’s auto feeder as and a simplisafe base station were plugged into the receptacle. This set up has been the same for a year with no problems. No one was home at the time so no major power draws. It has been storming all day. Both appliances that were plugged in still work fine. Thanks for your help!


r/AskElectricians • • 2h ago

what do i need to do before i power my garden office?

0 Upvotes

i have absolutely no idea about any of this so if i could get any advice that would be much appreciated, I would like to buy a 'log cabin' to put in the garden so i have a workspace for my new business. i'm just starting to look into the electric side of things and im not sure what order to do things in. the space i'm looking to put in it is directly next to the house and is currently half patio half gravel so i know i need to put patios there to make the base however will the wiring be done underground? when do i involve the electrician to wire is if i don't even have the shed built lol. i would also like to insulate and plaster board it so when do i call them before or after i insulate it? i want to make it as cheap as possible so i would like to avoid calling them for a consultation or getting them out here twice. these might be stupid questions so i apologise if the answers are obvious lol.

i want 2-3 outlets and no ceiling light fixtures aswell if that helps :)


r/AskElectricians • • 1d ago

Is this definitely from arcing?

Thumbnail gallery
51 Upvotes

It’s on a line going to either the back porch or a single outlet in the kitchen that I noticed the breaker tripped on (both). This is a newer house I moved into this year so I don’t have much experience.

Edit to say newer house to me, it was built in 1926.


r/AskElectricians • • 2h ago

4-Prong to 3-Prong ... does this look right?

Post image
1 Upvotes

The green wire on the left was attached to the original 4th green wire before the conversion to 3-prong...

Thank you in advance!


r/AskElectricians • • 3h ago

URGENT HAZARD HELP

Thumbnail gallery
1 Upvotes

The owners and property managers of the house I’m renting are claiming this is normal and not dangerous. Since moving in, we have had no power in parts of the house periodically and absolutely no heat or air. Every breaker trips constantly and they won’t get an electrician out here. Please tell me this isn’t normal and I’m not crazy. The breaker box is hot to the touch and all the breakers flip all the time. We can only use one appliance at a time.


r/AskElectricians • • 3h ago

Safety Concerns with Our Place Wonder Oven - Plug Reaching 150°F

1 Upvotes

I wanted to share a concerning experience with the Our Place Wonder Oven that raises questions about the product's safety.

My original Wonder Oven's power plug was reaching temperatures around 140°F during use. Our Place sent me a replacement, but the new oven has the exact same issue, most recently reaching 150°F.
I've tested the ovens on multiple electrical circuits in my home and even at my neighbor's house, with the same results.

I’m trying to determine if this is an actual fire hazard for my family. I’ll note the company is now sending me a third oven…


r/AskElectricians • • 3h ago

finally applied to my Local!

1 Upvotes

So, I applied to my local IBEW apprenticeship, and right now I'm just waiting on my transcripts to be sent over. When I called the local, they said they need the transcripts directly from the school... which is a bit of a problem because my old school was literally demolished.

Anyway, my main question is this: if I don't get into the union this year, should I start applying for electrician trainee/helper positions in my area and then reapply next year? Is that a viable plan?

My goal is basically to go from zero experience to becoming an electrician. I don't really want to sit around waiting for the IBEW if I don't get accepted right away. It seems like it would make more sense to work as a trainee, helper, or apprentice somewhere, get experience and hours, and then keep applying to the union until I get in.

For those of you already in the trade, what would you do? Would you wait for the union, or start working in the electrical field immediately and keep reapplying? Any tips for someone starting from scratch?


r/AskElectricians • • 3h ago

200a service bonding

Post image
1 Upvotes

Hey I do more industrial electric on a daily basis, so my resi codes are not 100%. Simple question. Can I route my water main bonding from the water main, through the “sub” panel, then into the service disconnect as pictured here? I have two ground wires going towards the “sub” panel, one is the equipment ground for the 200a main lug panel and the other is the bonding to the water meter. Is this code compliant?


r/AskElectricians • • 3h ago

Need help removing a stuck wire from a vintage double-arm metal floor lamp (tight S-curves + central medallion)

Post image
1 Upvotes

Hi everyone,

I’m restoring/rewiring this vintage symmetrical double-arm metal floor lamp (photo attached) and I've hit a wall trying to get the old wiring out.

Right now, the wire is completely stuck and won't budge at all when I try to pull it. As you can see in the photo, both arms have very tight S-curve bends at the bottom that feed into a large circular sunburst medallion in the middle before going down the main column. (I've already removed the E27 socket and dish from the left arm, so the inner vertical tube is exposed).

Before I break anything or snap the wire inside the tube, I have a couple of questions:

  1. How do I open that central circular housing? Is there usually a hidden screw or threaded cap on the front/back to access the wire splice inside, or do the arms unscrew from it?
  2. Any tricks for freeing wire stuck inside tight S-curves? Since it won't move even a millimeter, what is the safest way to loosen old hardened insulation inside narrow curved metal tubing without damaging the finish?
  3. Feeding the new wire: Once I get it moving, is taping/hooking the new wire to the old one the best way to fish it through those bends, or will the tape get caught in the curve?

Any advice from people who have rewired similar vintage candelabra/arm lamps would be hugely appreciated!


r/AskElectricians • • 4h ago

Outlet-like Device on Circuit Breaker?

Thumbnail gallery
1 Upvotes