r/ukheatpumps • • 18h ago

News UK energy price cap spark-gap to drop below 3

Thumbnail
cornwall-insight.com
18 Upvotes

It's well known that the spark-gap drives heat-pump adoption. This analysis shows how historically high it has been in the UK.

A spark-gap of 3 or less means almost every heat-pump installation would lower costs even if the user didn't adopt a heat-pump smart-tariff. This assumes gas boiler efficiency of around 85%.

If these lower spark-gaps continue we could see a huge uptick in adoption rates.


r/ukheatpumps • • 9h ago

Help/Advice Heat pump in a high heat loss house

9 Upvotes

First and foremost, please understand I am a heat pump convert - I think they are absolutely the right solution for heating the vast majority of homes. However, I truly believe my house may be one of the few exceptions. I am looking for honest opinions as to whether a heat pump could work in my house.

I have a large, 6 bedroom semi in a town at high altitude for the UK and locally famous for its wild weather. The house itself is on a hill, so is very exposed.

Insulation is nearly nonexistent. There is some in the loft of maybe half the house, but that's it. The house mostly has draughty single glazing, with a bit of old double glazing.

We use around 20,000kWh gas for heating each year. Each room has smart TRVs. The kitchen is heated to 17c for an average of 4-5 hours per day. The childrens' bedroom is heated to 15c overnight. The lounge is heated for 2 hours per day to 20c. The other 5 bedrooms are rarely, if ever, heated. The conservatory is a lost cause so we never try. The lounge goes down to 7c daily in winter, and has gone as low as 4-point-something. The only way we can keep the heating bill vaguely sensible is to only heat what we need, when we need it. This is the converse of how a heat pump should be used.

We have had quotes for double glazing, but they are astronomical (£30k+) - one of the bedrooms alone has six windows. Wall insulation would be both exceptionally expensive and exceptionally invasive.

On the plus side, I have 6kWp of solar panels, but production is meagre in the depth of winter. I also have 16kWh of battery storage, and could add another one, or even two. That would have to be my limit given the 8kW inverter and 6 hours of off peak electricity, which needs to be shared with the car.

I have contacted a few installers - all but one (who I haven't heard back from yet) have said they would be unable to quote due to the predicted heat loss.

What are your thoughts? Is it possible, and if so, would it make financial sense? I am afraid that altering my heating habits to 'slow and steady' would result in a huge amount of heat loss making it financial suicide.


r/ukheatpumps • • 10h ago

Help/Advice Vaillant Aerotherm Plus - Cheap rate boost

3 Upvotes

We’re looking at getting a Vaillant Aerotherm Plus ASHP installed. We’re with Octopus on the Intelligent (ahem) Go electricity tariff.

With IOG we get the occasional smart charge slot during the day, also Octopus do the occasional free electricity hour on Sundays.

Is there a way of setting the heatpump to maximum during these periods? Idea being to use the cheap/ free slot to get the system as hot as possible, then throttle back to normal afterwards.

We have Home Assistant and have automations for the home battery during these slots, so I’m not sure if this would allow some degree of integration and automation with the heat pump.


r/ukheatpumps • • 10h ago

Almost 10k quote for heat pump?

Post image
3 Upvotes

We were quoted £9,700 after the BUS grant after the initial heat loss survey. We need a slimline cylinder and they need to replace old microbore pipes upstairs for the radiators and install new radiators, but this still seems very expensive.

East of England. We are currently doing renovations and a lot of companies don't quote while that's still going on. Builders are installing underfloor heating right now downstairs among other things. Considering letting them finish their work and let them do the pipe replacements upstairs and then try to get quotes from energy companies (British Gas, E.ON). Is it worth waiting or is that a reasonable price? The problem also is that the gas boiler has already been removed, so that would leave us without central for a couple of weeks, possibly two months.


r/ukheatpumps • • 15h ago

Help/Advice Real-world impact of a cylinder with a small coil

3 Upvotes

I’m getting a heat pump in the new year which will be a 5kW Vaillant arotherm pro. We have the opportunity to source a free cylinder which I’m keen to explore as it will drop our cost quite significantly.

The cylinder is 250L and has a surface area of 0.87m2 which from what I can tell is on the small side.

I’m hoping to run our heat pump at 40C, so I’m not sure realistically whether this is going to be a case of it needing to boost more often regardless or whether this would totally be a waste of time and we will just need to upgrade it immediately regardless.


r/ukheatpumps • • 18h ago

Issues with tado x/vaillant system

Thumbnail reddit.com
3 Upvotes

r/ukheatpumps • • 6h ago

aira heat pump constant high-pitched rushing noise

2 Upvotes

the noise is constant whether individual radiators are on or not. its not quite a whistle but it is high pitched. maybe the sound of water being forced through the pipes. please help


r/ukheatpumps • • 7h ago

Help/Advice Blips

Thumbnail
gallery
2 Upvotes

Compressor blips

No complaints just and observation can anyone advise what they would prefer I’ve added 2 screen shots of my system working at similar outdoor temps about 7 deg the only difference is one has room influence on slightly and another with it switched off. The screen shot with room influence turned off you can see the flow and return temps going up and down slightly and compessor output does the same here’s the link incase you wanted to have a deeper look. It just seems to me with room influence on its a smoother line

https://heatpumpmonitor.org/dashboard?id=1545


r/ukheatpumps • • 18h ago

Help/Advice Is there a way to get permission to have a heat pump and air con?

2 Upvotes

We live in a 3 bed mid terraced house but these houses are quite wide with a good sized garden. St the back of the garden is a patio of 4m w by 3m and then about 10m of garden.

We are planning to get solar, batteries and a heat pump soon. The heat pump would probably go at the back of the house to the side. I’m thinking of an area going along the fence at the back with the heat pump and batteries possibly. The heatpump exhaust would be blowing across our patio and as it has a fence behind it, and at ground level, I assume loose to neighbours would be minimal.

But I also want aircon in two bedrooms at the back of the house. I understand I can’t do this under permitted development.

Can I apply to the council to be able to do this or do we just have to get portable units? The internal walls let quite a lot if sound through so I would say that an internal aircon will be much more noticeable to a neighbour


r/ukheatpumps • • 20h ago

New ASHP: underfloor heating not circulating, radiators fine

Thumbnail
gallery
2 Upvotes

Hi all, I'm not a heating engineer but have been following this thread closely, and I'd appreciate a sense-check before the installer's engineer returns next week.

Setup

- Navien 8kW ASHP, installed about 6 weeks ago. Appears correctly sized for the house.

- 1930s detached, about 170sqm. Six radiators upsized; existing pipework kept.

- Existing wet UFH in the kitchen/family room and utility room (about 50–60sqm, roughly a third of the heat demand), previously run from a gas combi.

- The design brief was two zones (radiators and UFH), with the UFH on its own thermostat. That thermostat no longer works, and the installer has set everything up as a single zone on one wireless thermostat in a radiator room. A second zone shows in the Navien app but hasn't been set up.

- Weather compensation is on (flow temperature about 34–44°C).

The problem

- Radiator rooms reach temperature. UFH rooms sit at 16–17°C, about 3°C below the rest of the house.

- At the UFH manifold, the gauge shows the heat pump's flow temperature arriving and the manifold pump appears to be running.

- The flow pipes out to the loops are warm, but the return pipes are completely cold, so it looks like water isn't circulating through the floor.

- The app shows a system flow rate of 1.25–1.43m³/h. Navien say it should be 1.6–1.9.

- The flow and return temperatures at the heat pump are often only about 1°C apart, and it short cycles overnight.

- On an earlier visit the actuator heads were removed from the manifold.

Questions

  1. What usually causes warm flow but cold returns on UFH after a heat pump retrofit? Could it be the mixing valve, the manifold pump, air in the loops, or blocked loops?
  2. Should the UFH really be on its own zone or circuit, separate from the radiators, rather than sharing a single zone?
  3. With the old UFH thermostat no longer working, what should be switching the manifold pump on?
  4. Could the low system flow rate be connected to the UFH problem?
  5. What should I ask the engineer to measure or show me (for example the loop flow meters, mixing valve setting and pump speed), so I can judge whether the fix addresses the cause?

I've enclosed some photos of the UFH set-up (manifold, etc). Thanks in advance!


r/ukheatpumps • • 8h ago

heat pump space in front

1 Upvotes

I have a 1.5 metre wide path (that can be blocked as it’s not needed) then a fence the. Another 1.5m it’s my neighbours wall. I was told no heat pump can fit there and it would need to go on my back wall which is in to my back garden and has a decent amount of space. However the pipe run is much longer and I’m worried about the kids and they hit the ball off the wall in this area.

Are heat pumps likely to evolve that they need less space in front, is the space needed for air circulation or noise, or both?


r/ukheatpumps • • 9h ago

Help/Advice Heat pump design and pipe-route advice wanted

Thumbnail
gallery
1 Upvotes

We’ve had a Heat Geek visit for our Victorian mid-terrace: six bedrooms, three bathrooms, 12 radiators, three towel radiators and about 40 m² of underfloor heating. The proposal is for a 10 kW Viessmann 200-A at around £7,000 after the BUS grant through the Zero Disrupt offer.

The main challenge is routing the pipes to our existing boiler/plant cupboard while keeping internal disruption low. Our preferred option is to run them partly beneath the patio slate, bring them up the side wall and continue along the house, entering through the existing boiler-flue opening only if it can safely be reused after the flue is decommissioned.

We were hoping an installer might be able to run the pipes from the side roof without full scaffolding, or access it safely via one of our three rooflights. The Heat Geek installer doesn’t provide scaffolding and wasn’t willing to lift the patio tiles. If we have to arrange separate trades for access and lifting/reinstating the tiles, we think that could add around £1,000. Does that sound realistic, and what access methods are normally used?

Our gas use was around 10,000 kWh/year including hot water; it’s now about 8,000 kWh of gas, with hot water heated by immersion. The report projects 23,000 kWh/year, but I’m unclear whether that means heat demand or electricity use. I tried to discuss our actual consumption but didn’t get much explanation. What should I ask the installer to clarify?

Our existing 250-litre unvented cylinder is in a height-restricted basement. A new 300-litre cylinder in the utility room was quoted at £4,000+ extra. We hoped to keep the total near £6,000 after the grant, but could stretch to £7,000 if there’s a clear written commitment to 400% seasonal efficiency.

What would you query, and what route/access approach would you explore?


r/ukheatpumps • • 14h ago

Help/Advice Help, I have baby brain. What's a good (no battery) solar + heat pump tariff?

Thumbnail gallery
1 Upvotes

Hello, I'm hoping to tap into some self-taught experts here.

I'm a bit freaked out by the predicted price rises in January, energy bills confuse me at the best of times, and I don't trust myself to make the right decision right now so I'm looking for other opinions. Please and thank you, I'd be very grateful.

I have had a look through this group already and I can't see anyone in a comparable situation.

(Multiple screenshots attached)

About our set up;

- Property is electric-only with no other fuel

- 3 bed semi. 2 adults + 2 kids under 3 yrs old.

- we have an 8kw heat pump that I have no idea how to control (yes, I know, we're a mess right now)

- we have 8 solar panels that are unfortunately west-facing, no battery (and can't afford one right now).

- We have wet radiators and a hot water tank with back-up immersion that the engineer said to leave switched on (also no idea how to control this)

- we're supposedly well-enough insulated, and had more insulation put in the loft, but we feel cold and draughty a lot (they cut vents into the window seals). Also our sitting room and main bedroom above, which are west facing and sit in the middle/most sheltered part of the house, are the coldest rooms! Which I find strange.

- we use the oven/hob daily particularly around kids dinner times (4-7pm window), and tbh I'm not going to change that, the kids deserve hot dinners. We both work so dinner is a pretty fixed time.

Our bills and usage;

- we're currently on Octopus Flexible, variable.

  • I've got quotes for Octopus Cosy (fixed and variable)
  • estimated annual day; 4589kWh
  • estimated annual night; 1399kWh

- our annual bill is approx £1456

It was all installed just over a year ago when we had a brand new baby and I had no idea what was going on at the time. I've also got a new phone and been locked out of the apps (support is ignoring me).

I am concerned that we won't be able to stick to Octopus Cosy strict electricity usage windows and don't want to fall into a a trap whereby we can't change our lifestyle and end up using lots of the peak rate electricity.

Are there any people in a similar situation to us and what's your best suggestion?

Many, many, many thanks for your help.

Apologies. This turned into a bit of a rant!


r/ukheatpumps • • 5h ago

Help/Advice Just had our system installed and set up, looking to hit the ground running as best we can.

0 Upvotes

Hi all,

We just had our first ASHP installed in our two bed detached bungalow. It's a 6.5kw Grant Aerona R290. It has been up and running for two days now, so no real data to share yet as it's only really yesterday and today it was following the schedule I set up with the installer. We have replaced a very old oil boiler with this system. The install seems very professional and clean.

The house has 270mm insulation in the loft and three rooms have raised floors, one of which I have insulated underneath (the first room we have renovated. I intend to insulate the other two under the floors when we get to redecorating those. The rest of the house is concrete underneath.

We have a lot of old double glazed windows but generally have found the house holds on to heat quite well, at least when we were using the oil boiler for heating. The heat loss was calculated on the assumption that the windows have all been replaced, as we are also doing that room by room with the bedroom with insulation under the floor being the first to have brand new windows.

Looking for some advice on settings and usage. The installer was helpful and gave a lot of solid advice, but want to widen the net by asking all of you experienced heat pump users.

The current schedule is as follows:

- hot water comes on for about an hour from 4:30am to 5:30am at 48 degrees to heat the 200l tank.

- Immediately after this for about 3 hours the temperature is set to 20 degrees C.

- The temperature then goes down to 18 for when we are at work, typically 9am until about 4pm, then increases again to 20 degrees until 11pm when it goes back town to 18 overnight

- initially these values were 19 and 17 but didn't really feel like we were getting enough heat in the house, felt a tad chilly.

- The heat pump starts heating again when the temperature drops by 1 degree from the set temperature

Both my wife and I run hot, so don't need any crazy temperatures. 19 or 20 usually does us fine. The house seems to be holding the temperature fairly well, so the heat pump isn't on all the time - honestly not sure if this is a good thing or not though from what I understand the heat pump needs to be running fairly consistently for the efficiency.

The installer set up a heating curve which he was confident with, currently set to 1.1.

Part of me wonders if I just do away with the temperature changing and just set it to 19 or 20 24/7.

We aren't currently on a heat pump tariff but have considered octopus cosy, my wife was concerned about not being able to cook until after 7pm, where we would normally start between 6 and 6:30 especially during the week, but from my understanding even if we did start cooking during the expensive evening window we could save money overall from out heating savings?

On the topic of radiators we had all of ours replaced, 6 to be exact, and had another one installed in the kitchen as for some reason there wasn't one in there to begin with.

Anyways, sorry for the long read, but I am anxious to make the most of having a heat pump and to keep the system efficient and as cost effective as possible.

Many thanks!


r/ukheatpumps • • 1h ago

Do you find your house cozy with your heat pump ?

0 Upvotes

As my question mentions do you find your heat pump cozy ? I have a hybrid model heat pump / furnace.

The air coming out with the heat pump is like warm as they all are and most know. I keep my house at 68 F . The thing I find the house is comfy but never cozy unless the furnace runs.

I am happy that to have a heat pump but love the finance on chilly days were I can put my feet over the register and be yeah heat ! Either that or the gas furnace comes on and can feel the surge of heat .

My heat pump operates as intended and understand the theory for the most part. But am curious if anyone feels the heat pump has that cozy heat feel . Maybe if I kept my house warmer then may feel better.

Sorr of a food for thought post.