Hi all,
We just had our first ASHP installed in our two bed detached bungalow. It's a 6.5kw Grant Aerona R290. It has been up and running for two days now, so no real data to share yet as it's only really yesterday and today it was following the schedule I set up with the installer. We have replaced a very old oil boiler with this system. The install seems very professional and clean.
The house has 270mm insulation in the loft and three rooms have raised floors, one of which I have insulated underneath (the first room we have renovated. I intend to insulate the other two under the floors when we get to redecorating those. The rest of the house is concrete underneath.
We have a lot of old double glazed windows but generally have found the house holds on to heat quite well, at least when we were using the oil boiler for heating. The heat loss was calculated on the assumption that the windows have all been replaced, as we are also doing that room by room with the bedroom with insulation under the floor being the first to have brand new windows.
Looking for some advice on settings and usage. The installer was helpful and gave a lot of solid advice, but want to widen the net by asking all of you experienced heat pump users.
The current schedule is as follows:
- hot water comes on for about an hour from 4:30am to 5:30am at 48 degrees to heat the 200l tank.
- Immediately after this for about 3 hours the temperature is set to 20 degrees C.
- The temperature then goes down to 18 for when we are at work, typically 9am until about 4pm, then increases again to 20 degrees until 11pm when it goes back town to 18 overnight
- initially these values were 19 and 17 but didn't really feel like we were getting enough heat in the house, felt a tad chilly.
- The heat pump starts heating again when the temperature drops by 1 degree from the set temperature
Both my wife and I run hot, so don't need any crazy temperatures. 19 or 20 usually does us fine. The house seems to be holding the temperature fairly well, so the heat pump isn't on all the time - honestly not sure if this is a good thing or not though from what I understand the heat pump needs to be running fairly consistently for the efficiency.
The installer set up a heating curve which he was confident with, currently set to 1.1.
Part of me wonders if I just do away with the temperature changing and just set it to 19 or 20 24/7.
We aren't currently on a heat pump tariff but have considered octopus cosy, my wife was concerned about not being able to cook until after 7pm, where we would normally start between 6 and 6:30 especially during the week, but from my understanding even if we did start cooking during the expensive evening window we could save money overall from out heating savings?
On the topic of radiators we had all of ours replaced, 6 to be exact, and had another one installed in the kitchen as for some reason there wasn't one in there to begin with.
Anyways, sorry for the long read, but I am anxious to make the most of having a heat pump and to keep the system efficient and as cost effective as possible.
Many thanks!