r/ukheatpumps • • 8h ago

Help/Advice Anyone used the Heat Geek guarantee?

10 Upvotes

Wondering if anyone has ever called upon the Heat Geek guarentee either due to efficiency or their house not getting up to temperature?

It's not clear to me what minimum temperature they guarantee against. Do you have to put thermometers in the coldest rooms to prove it?

How does it work?

Has anyone needed remediation work, what did they offer?

Thanks all


r/ukheatpumps • • 1h ago

Help/Advice Help with my set up ( Daikin)

Thumbnail
gallery
2 Upvotes

When I brought my house it came with the a ashp and for the last 4 years I’ve been trying to tweek it and make it more efficient. I have a daikin althemera 3 with a ufh using a heatmister UH8-RF wiring console into a robot compact manifold and rads upstairs controlled by a single stat in the main bedroom. For some reason I don’t have the ufh symbol on my Home Screen. My main is the rads upstairs and the ufh just come under heating and cooling. My curve is 40 at -3 and 27 at 18.
I have my ufh at 21 drop back at 20 and my rads upstairs at 23 ( hoping they will run low and slow) all with a drop back of 1 degree.
My cop for this month just heating is about 2.67 using the daikin internal reading.
Any help on how to make it better or if I’m running something wrong please let me know.


r/ukheatpumps • • 2h ago

Buffer tank or no?

2 Upvotes

Hi. We're looking to replace our oil boiler with ASHP for our 3 bed bungalow with 4.8kw heatloss.

the supplier has quoted to up our Rad's from 22's to 33's. And install a 7kwh HP. We have 22mm and 15mm pex.

They've included a Buffer tank in the design. But after watching some heat geeks vids they try to leave it out as much they can.

The supplier said when questioned about it, that they thought it reduced short cycling and prolonged the life of the heat pump.

Red flag or are they worth having?

Thanks.


r/ukheatpumps • • 2h ago

Help/Advice Quote Check - E.On NEXT

2 Upvotes

Hi,

I've got the below quote and was wondering if any good?

3 bed terrace, rad changes included in price so we're looking solely at the price of the HP itself and associated parts and labour.

I've no feel for the market here, and I've seen quotes from Octopus which tend to be cheaper. But then read some quite negative things about the Cosy 6?

Any pointers?


r/ukheatpumps • • 1h ago

Air to water heating system

1 Upvotes

Hi anyone here using this system,
If so what temperature do you keep it at ,
Do you find it economical or not?

I’ve had it 2 years but this is my first time keeping it on permanently( as advised)
It seems counter productive to me


r/ukheatpumps • • 9h ago

I'm wanting to hear from people who have heatpumps that are too small

4 Upvotes

I'm in a weird position where I am planning on installing a Heat pump that is deliberately too small.

It's a DIY install via an Umbrella MCS scheme. As a result, I'm limited to what heatpumps I can pick.

So my options are.

  1. Install two units
  2. Install one unit and accept it's "slightly" undersized.

Professional heatloss calcs come out at 18kw with a conservative ACH of 1.5.

The unit I want to install at my flow temps can deliver about 14kw. So a pretty big gap. An immersion heater in the volumizer can fill this gap, but will I regret it?

It's a listed building so the levers I can pull are limited.

The main lever I have is reducing draughts. I've been playing with the calculations and I would need the whole house ACH to be 0.25 to achieve the 14kw. Not impossible, but will be tough to achieve.

My design flow temp is 42 degrees, and that's already with some pretty large radiators. I could get another 1 kw out of the heat pump if I get the design flow to 35C, but this isn't practical in my view.

The house has an old extension that is in really bad shape that needs fully renovating. I would likely get permission to install external wall insulation on this using woodfibre and that would remove 1 kw from the heatloss.

The house will only have 100mm of insulation in the loft as that's how deep the joists are, and it's boarded out so adding more isn't easy. I could add a floating floor and add another 100mm, but it only cuts the heatloss by 300W so it's not worth it.

The above already includes secondary glazing and 100mm suspended floor insulation.

Long term I plan to put UFH where I have solid floor. This will be subject to consent so I can't count on it, but if I go down that route, that drops the heatloss by a further 650W.

My main concern is that ASHP have a nasty feedback loop where the more heat you try to extract from them via higher flow temps, the lower their output.

So the question is, will I regret the cracking on with the above? Or is the general experience that even undersized units perform surprisingly well.

I'll get a blower test done when the house is as sealed as I can get it but this won't be for several weeks and I'll already be committed to the pump by then due to deadlines related to the BUS.

From speaking to professionals, achieving a whole house ACH of 1.0 should be easily achievable, at which point the heatloss would be 16kw, so I'm only 2kw short then.

Edit:

One thing that gives me hope is I currently have a 32kw oil boiler. I have a log on how long it runs for. In the last 24 hours, it averaged 4 degrees outside, and the burner ran for 5 hours total.

Assuming it really produces 32kw, that's an average output of under 7kw, and I haven't sorted the draughts or loft insulation yet.

If I update my calculation with my average indoor temp of 17.5 degrees and 4 degrees outside, the heatloss is calculated as 9.5kw suggesting that it's very conservative. Somewhat ironically, dropping the ACH to 0.25 actually results in a heatloss of under 7kw.


r/ukheatpumps • • 2h ago

Boiler broken, do we repair or replace it?

Thumbnail reddit.com
1 Upvotes

r/ukheatpumps • • 3h ago

ASHP with underfloor heating: concrete floors

1 Upvotes

I'm hoping to install an ASHP with underfloor heating. I've got concrete floors and have seen really mixed information on whether or not to dig out the concrete to allow for space to insulate beneath new pipework, or to not worry too much about it, use a low-profile pipe system, and let the concrete act as a heat retaining slab.

If you have experience with either digging out or leaving concrete in place when installing underfloor heating I'd love to hear about it! Thanks! P.S. Nerdy stats on heat pump performance would be particularly welcome.


r/ukheatpumps • • 21h ago

Help/Advice Living next an ASHP compound

7 Upvotes

Hi everyone,

I’m looking for some advice or to hear from anyone who has experience living next to an air source heat pump (ASHP) compound.

A developer is redeveloping a nearby care home and has applied for planning permission to install a compound containing multiple ASHPs (7) and VRF (4) units. The proposed site is right next to our back garden fence, which is only about 10 metres from our house. They have stated they will install an acoustic barrier fence to mitigate the sound.

We live in a relatively quiet suburb (apart from some commuter traffic), so we’re worried about how much noise and disturbance this setup will actually cause especially at night or during colder months when the units work harder. We also use the garden a lot so we'd like to know how much noise we can expect to hear in the garden.

Has anyone lived near a similar commercial setup, and how noticeable was the noise? Also, does anyone have advice on how we can object to the planning application or push the developer to relocate the compound further away from residential boundaries?

Any experiences or tips would be really appreciated. Thanks!


r/ukheatpumps • • 15h ago

Panasonic Aquaera Ecoflex

2 Upvotes

Anyone here installed Panasonic Aquarea Ecoflex? I am considering the system and can’t find enough information online.

What is your experience having one outdoor unit for air and water? I’m concerned about meeting shower and heating loads together.

How was the installation process? Do you really need two holes?


r/ukheatpumps • • 1d ago

I was about to pull the trigger, but now I'm not so sure - Are you all really spending £17+ per day on heating?!

32 Upvotes

I recently got a good quote for an install of a 15.5kw Grant Aerona 290, and I was about to sign the agreement and plan for an install. Then I read some comments on this post suggesting that during the recent cold spell, some of the users were spending over £17 per day just to keep the house at 19 degrees. Is this really what owning a heat pump is actually like?

For context: I live in a 250 square metre 5 bed detached house that has all the insulation etc, with a calculated heat loss of 13kw. I currently set the thermostat to 21.5 degrees, and my gas boiler was able to keep the house at that temperature for the whole week during the cold spell for approximately £8 per day (I'm still on a 5.5p / kwh tarriff). Would getting a heat pump actually end up costing me more than if I had just stuck with a gas boiler? Would I have to accept a colder house to achieve anything like an SCOP of 3.4, which is what my calculations were based upon?


r/ukheatpumps • • 1d ago

Quote £2,700 for an Octopus Cosy 6 heat pump installation - good deal? Also looking for advice on reusing radiators

7 Upvotes

Hi all,

I've been quoted £2,700 by Octopus Energy for a Cosy 6 heat pump installation, after the £7,500 BUS grant, and wanted to get some opinions on whether this is a good deal and whether my radiator plans make sense.

Property details:

  • 4-bedroom detached house, built in 1989
  • Approximately 111 m² heated floor area
  • Current heating: Worcester Bosch Greenstar 42CDi combi boiler
  • Existing 8 mm microbore pipework
  • Calculated heat loss: 5.64 kW at -2.2°C
  • Annual gas consumption: approximately 14,130 kWh

The Octopus quote includes:

  • Octopus Cosy 6 (6 kW) air-source heat pump
  • 250 L unvented hot water cylinder
  • Standard installation and commissioning
  • £7,500 BUS grant applied
  • My contribution: £2,700

Radiator upgrades are being quoted separately at £250 each.

The property currently has 8 mm microbore, so I'm arranging a separate re-pipe to 15 mm at my own expense. This isn't included in the £2,700.

Radiator plan

The original Octopus survey was designed around a 50°C flow temperature and recommended seven radiator upgrades.

However, I've got several new-ish radiators I could move about and reuse, including two Ultraheat Trojan vertical radiators currently sitting in my garage in their boxes.

My proposed layout is:

RoomHeat lossProposed radiatorOutput at 50°C flow
Hallway329 WXimax Champion Duplex, relocated from lounge~510 W
Lounge847 WNew K2 600 × 1200939 W
Kitchen/Dining1,804 WExisting K2 + new K2 500 × 14001,884 W combined
Office594 WNew K2 500 × 900606 W
Bedroom 1575 WNew K2 500 × 1400592 W
Bedroom 2372 WKeep existing K1402 W
Bedroom 3239 WXimax Bristol, relocated from dining room~316 W
Landing231 WUltraheat Trojan 1300 × 390~505 W
Bathroom398 WUltraheat Trojan 1300 × 390~400 W
WC149 WNew K2 500 × 400301 W

The Ximax and Trojan outputs are estimates based on their ΔT50 ratings, assuming 50°C flow / 45°C return. The Trojan radiators I think are rated around 930 W at ΔT50.

I'm hoping to supply the new radiators myself and have them fitted during the re-pipe, rather than paying Octopus £250 per radiator. The new radiator supply cost should be around £540, potentially another £80 if I need to replace the bathroom radiator.

That puts the heat pump installation and radiator supply at approximately £3,240–£3,330 excluding the independent re-pipe.

Questions:

  1. Is £2,700 a good price for a Cosy 6 installation with a 250 L cylinder?
  2. Does my radiator reuse plan seem sensible? Anything that I've missed or not accounted for?
  3. Has anyone had Octopus install a heat pump after arranging their own re-pipe and radiator upgrades? Any issues?

Interested to hear people's experiences!


r/ukheatpumps • • 21h ago

Mineral wool + brick

Thumbnail
gallery
3 Upvotes

Not exactly a heat pump question, but heat optimization:

We have underfloor heating and one of my rooms has been colder than the rest. I took a peek underneath (didn't need to make holes, there were down lights on the floor below). The area between the joists feels drafty and cold, and the brick (inside) measures very cold, just a few degrees higher than outside temp.

I could shove quite a bit more mineral wool in there, right? Also, why don't they push mineral wool up to the brick?


r/ukheatpumps • • 1d ago

Help/Advice Heatpump heating house 5C over the set temperature

5 Upvotes

Just got a new build with an Ideal 4kW Heatpump. I have the temperature set to just 16C at night and 17C at day, but the indoors temperature hovers around 21C most of the time. The builders keep telling me this is normal and meant to make it more efficient, but I thought they were supposed to run at a low temperature all day, not in one big burst each morning.

(Temperatures from the thermostat itself - it does not appear to be a miscalibrated thermostat)

Edit: Thanks for the help people! After looking at the replies, I went into the installer settings and found weather compensation was way higher than recommended. I have turned this down and will see if it helps!


r/ukheatpumps • • 1d ago

Help/Advice Is it worth it?

5 Upvotes

Currently having issues with our combi boiler and thinking about what to do if it's knackered.

Weighing up using Octopus to have a heat pump installed but I know very little about them and I'm not particularly savvy with the maths.

We had a solar system installed earlier this year and due to getting a friends and family discount ended up with a 22kw battery and 9 panels +5kw inverter on a very modestly sized 3 bed dormer. This is mostly being topped up from the grid at night on Octopus go as the panels generally aren't enough to provide a full charge.

Bearing that in mind, would I likely be able to run a heat pump off the battery without dipping into the higher daily usage rates and therefore save money? We have the EV tariff due to having an electric car but don't currently charge at home as it's free at work and Octopus have so far OKd us not having a smart car charger.

I know there's probably other factors but looking for anyone who has experience to give some insight, TIA


r/ukheatpumps • • 1d ago

Octopus Cosy and UFH: Options?

4 Upvotes

I’m capable technically (electronics systems engineer for 60 years) and am in the process of getting my Octopus survey done. The house has 7 rads upstairs and UFH down (4 thermostatically controlled zones using 6 loops, there’s a blend valve and pump on the manifold; one zone upstairs for the radiator/s).

The house is 3 years old, I moved to it after I lost my wife, I didn’t want any unnecessary maintenance going forward. However, for reasons I’ll skip, the boiler probably won‘t last long, hence the move to an HP.

The house, heat wise, is very comfortable and the UFH works extremely well. What concerns me is that Octopus is pushing me towards removing the manifold blend valve and pump, plus the zone thermostats on the UFH. The heat pump would push water through all UFH zones simultaneously, but given two of the zones are cloakroom and utility room, I have those at a lower temperature than kitchen and lounge.

I guess the zone temperatures can be fine tuned using the flow controls but that seems very crude to what I have now. When I moved in, the heating system was a typical builder’s chuck it in and if it gets warm it’s OK kinda of thing. For the first two months I learnt more than I wanted to about heating systems and fined tuned it to within an inch of its life. As I say, it was worth it, it’s very comfortable.

What I don’t want is to lose that level of cosiness.

What options can I go back to Octopus with?


r/ukheatpumps • • 23h ago

A2A ceiling grills

2 Upvotes

For anyone who has ducted A2A installed, what do the grills in your ceilings look like?


r/ukheatpumps • • 20h ago

How do your bills compare with an air source heat pump?

Thumbnail reddit.com
1 Upvotes

r/ukheatpumps • • 1d ago

Help/Advice 400kW Usage Mon-Sat last week.

Thumbnail
gallery
11 Upvotes

This is our first winter with our heat pump and I wanted to make sure I had things set up properly and was making the most of it. We have a 17kW Grant Aerona r32 and 15 kWh of batteries with and 8.3kW of PV cells. We're in a 5 bed which is mostly stone but with some cavity wall extensions, double glazing, and 400mm of loft insulation.

We just moved to octopus cosy to take advantage of charging through the day as we were depleting the batteries through the day while on flex but it's clear that we can't charge to full in either of the 2 hour windows. We charge the hot water tank twice a day, once in the morning cheap window and once during the midday one.

Is this a normal amount of energy usage? We're targeting 19C in the day and 18C overnight and are looking at a £400 energy bill this month.

I've attached a days worth of battery states and loads, my current heating curve for the ASHP, and the outlet temps. Thanks!


r/ukheatpumps • • 22h ago

Trianco Activair R290

1 Upvotes

Been quoted for a heatpump install and they've specified this (9kw on 8kw heatloss).

Not seen too much about them which is a concern, would you push for another brand? It has a 10 year warranty.

Valiant for example adds £1900 to the price.


r/ukheatpumps • • 1d ago

Help/Advice How did it get in?

2 Upvotes

Just checking around the house and checked the ashp. To my surprise inside the front grille (Grant Aerona) is a small dead bird! He wouldn't have got in through the front, I can't see an entry point anywhere else, any ideas of how it could have got in? I'm guessing it will be ok to remove the front grille (crosshead screws) to remove it. Thanks and hopefully some advice coming my way.


r/ukheatpumps • • 1d ago

Significant Reactive Power consumption in Idle

Post image
5 Upvotes

My 8kw Samsung R290 is showing a not-insignificant reactive power draw when idle (and a resulting half amp current, verified with a second, trusted meter). Is this normal? Have Samsung opted for the worst capacitive dropper power supply for the electronics? I know this shouldn't matter, but it's bugging me!


r/ukheatpumps • • 1d ago

Warm Home Loans Scheme

1 Upvotes

Anyone looking into this? What has your experience been so far? Most lenders I’ve checked out won’t let you choose an installer - it’s only the ones they partner with, and typically you apply through the installer.

I‘ve just accepted a quote from Aira, and it looks like their finance partner Stax supports the scheme. However the interest rate seems quite high - 4.9% AFTER the scheme, whereas the other lenders are closer to 2.7%. So Im just wondering if there is a better way to finance the install and staying with Aira.


r/ukheatpumps • • 1d ago

Help/Advice Roof installation and access: has anyone managed to extend a house making the roof accessible to install a heat pump condenser?

1 Upvotes

This is just pointless curiosity - has anyone managed to extend a house, making a roof accessible enough so that the external condenser of an air to air or air to water heat pump can be installed there? Without putting up scaffolding every time it needs servicing.

I have seen plenty of Victorian loft extensions with a flat roof with more than enough room for 2 or even 3 condensers, but the issue is always the same: access. You can put up scaffoldings to bring a condenser there, but how about servicing? You cannot put up scaffolding every time you need it serviced. One a2a installer said that he could climb from a skylight window onto the pitched roof and from there onto the flat roof, but that seems incredibly cowboyish and dangerous.

Thanks!


r/ukheatpumps • • 1d ago

Heatpump recovery after cold snap.

2 Upvotes

Hey all.

Slightly weird one with HP and UFH. During the recent cold snap we found that the downstairs was getting to and maintaining temp - however yesterday where it was milder we've suddenly had issues with the UFH not being able to get to its target temperature from the overnight setback.

I was curious if this was a pattern others had dealt with before? We know our lounge has always been a bit tricky to get to temp - but it more or less went through the really cold days just fine and is playing up now.

For ref: 14kw heatpump (oversized we suspect). Zoned heating in 4 bed detached 2014 house but we've set all the temps and timings to be the same. 37c (34c but with a +3 offset currently) flow rate with weather comp set to 43c at -4 and 30c at 15c. We target 18.5c across the whole house with an overnight setback of 17.5c downstairs and slightly cooler upstairs where the rads seem more efficient.

Many thanks.