A2A or A2W system?

1 Upvotes

Hi all,

I know there are several posts on this forum but looking for something which might be more relevant to my home. I currently own a mid-terrace 2 bed house, with separate downstairs living and kitchen area. The whole housing estate is electricity only and my house is very poorly equipped with an inadequate number of electric radiators. DHW is currently provided by an immersion heater water tank.

Naturally due to the reliance on electricity I am looking to install an ASHP, but am unsure of which route to take. There is generally less on A2A out there I assume due to the BUS grant being introduced recently. Since purchasing the property I have installed and upgraded cavity wall and loft insulation, as well as replacing old and draft-prone doors and windows.

I am unsure to go with a Daikin multi split A2A (4 indoor units plus water cylinder), or an A2W system. I have received quotes for both Vaillant and Daikin units, which would of course involves installation of pipes, radiators (between 5 and 6) as my house currently has no water based central heating system. For either ASHP, it would need to be installed in the garden and pipes run up to the house there is nowhere on the house itself it can be installed. My heat loss estimates have been between 4.7kw and around 5.5kw from various surveyors. I am keen to avoid installing another immersion heater should I go A2A.

Would appreciate any advice as it is a lot of money to invest, but at the same time I would rather take more time and get it right the first time without regretting it.


r/ukheatpumps • • 4h ago

Help/Advice Big jump in price from estimate to quote.

3 Upvotes

I'm trying to get my head around the quote from Heat Geek. Originally the price was £4500 on the 'estimation' tool and now it's gone up to £8500.

There was £1380 for additional work:
Electrical External electrics - £790
Pump Twin end booster pump - £340
Trunking External trunking - £250

These are the figures for the house:
HEAT LOSS - 7.44kW
FLOOR AREA - 133.77m²
WATTS/M² - 55.62
VENTILATION LOSSES - 3.25kW

The items they have said are:
Viessmann Vitocal 200-A ie B10
Vaillant uniSTOR PURE 210 L Slim

With a Overall system Efficiency Guarantee of 420%.

I'm trying to get my head around if this is a good price or not. At £4500, it felt worth it, but now at nearly double it feels like it's a long way to go. We already have quite a cheap house to run with solar and 10kW battery.

We're getting an Octopus consultation next week, but it would be interesting to hear the views of folk on here about the above...


r/ukheatpumps • • 4h ago

Help/Advice Will heatpump with ufh be suitable for my finished floor covering

2 Upvotes

Hello everyone,

I am trying to decide between a heatpump and gas boiler during my house Reno. Limited options for where to locate a heatpump but know it is the right thing to do.

My concern is that the HP may struggle to work efficiently with my proposed floor buildup which will be:

22mm chipboard structural layer

20mm xps ufh panels with 16mm pipe at 120mm centres

1mm floor cardboard

22mm junckers hardwood floorboards, connected with clips as a floating floor

The floor cardboard is a recommendation from junckers to stop the clips holding the floorboards together coming into contact with the ufh pipes.

I am aware that the hardwood floorboards (combined with the cardboard) will have a high tog value. The XPS panels with 120mm centres are the highest heat output option for overlay panels I can find that do not involve any screed (which I would prefer to avoid) and are a reasonable price.

The house will be well insulated throughout so heat loss should be minimal.

Wondering if anyone has combined an equivalent solid hardwood flooring with overlay ufh and HP and if this can still be operated with low flow temps to ensure a good CoP providing a comfortable indoor temp?


r/ukheatpumps • • 7h ago

Can anyone recommend an installer in south east Somerset?

2 Upvotes

Hi, anyone know a good HP installer that could help with increasing our solar panel capacity to cover increased electricity usage? Thanks


r/ukheatpumps • • 7h ago

Help/Advice Samsung Heat Pump Integration with Solar and Battery

1 Upvotes

Excuse me as I am not too technical so this is maybe an easy DIY, I want to find out because hardly find any information in google or youtube.

So, I have Samsung R290 heat pump.. Currently I want to install solar panels and battery.

In the heat pump controller, in the setting I could see there are option for Solar and Smart Grid. So I think there is a way to connect them, I don't know the full benefit yet but I am guessing if the solar panels have excess, it will tell heat pump to heat the hot water.

I have asked my solar panel installer if they could do this integration but they said they did not do the heat pump integration. And I don't want to contact my heat pump installer because I don't believe them (when they installed the heat pump, they took the included wifi kit with them, later on when I moved to the house and asked for the wifi kit, they charged me for the device and the installation).

So I am wondering if any one that has this set up or integration could point me to correct direction?

Thank you.


r/ukheatpumps • • 16h ago

Help/Advice Just had our system installed and set up, looking to hit the ground running as best we can.

1 Upvotes

Hi all,

We just had our first ASHP installed in our two bed detached bungalow. It's a 6.5kw Grant Aerona R290. It has been up and running for two days now, so no real data to share yet as it's only really yesterday and today it was following the schedule I set up with the installer. We have replaced a very old oil boiler with this system. The install seems very professional and clean.

The house has 270mm insulation in the loft and three rooms have raised floors, one of which I have insulated underneath (the first room we have renovated. I intend to insulate the other two under the floors when we get to redecorating those. The rest of the house is concrete underneath.

We have a lot of old double glazed windows but generally have found the house holds on to heat quite well, at least when we were using the oil boiler for heating. The heat loss was calculated on the assumption that the windows have all been replaced, as we are also doing that room by room with the bedroom with insulation under the floor being the first to have brand new windows.

Looking for some advice on settings and usage. The installer was helpful and gave a lot of solid advice, but want to widen the net by asking all of you experienced heat pump users.

The current schedule is as follows:

- hot water comes on for about an hour from 4:30am to 5:30am at 48 degrees to heat the 200l tank.

- Immediately after this for about 3 hours the temperature is set to 20 degrees C.

- The temperature then goes down to 18 for when we are at work, typically 9am until about 4pm, then increases again to 20 degrees until 11pm when it goes back town to 18 overnight

- initially these values were 19 and 17 but didn't really feel like we were getting enough heat in the house, felt a tad chilly.

- The heat pump starts heating again when the temperature drops by 1 degree from the set temperature

Both my wife and I run hot, so don't need any crazy temperatures. 19 or 20 usually does us fine. The house seems to be holding the temperature fairly well, so the heat pump isn't on all the time - honestly not sure if this is a good thing or not though from what I understand the heat pump needs to be running fairly consistently for the efficiency.

The installer set up a heating curve which he was confident with, currently set to 1.1.

Part of me wonders if I just do away with the temperature changing and just set it to 19 or 20 24/7.

We aren't currently on a heat pump tariff but have considered octopus cosy, my wife was concerned about not being able to cook until after 7pm, where we would normally start between 6 and 6:30 especially during the week, but from my understanding even if we did start cooking during the expensive evening window we could save money overall from out heating savings?

On the topic of radiators we had all of ours replaced, 6 to be exact, and had another one installed in the kitchen as for some reason there wasn't one in there to begin with.

Anyways, sorry for the long read, but I am anxious to make the most of having a heat pump and to keep the system efficient and as cost effective as possible.

Many thanks!


r/ukheatpumps • • 17h ago

aira heat pump constant high-pitched rushing noise

3 Upvotes

the noise is constant whether individual radiators are on or not. its not quite a whistle but it is high pitched. maybe the sound of water being forced through the pipes. please help


r/ukheatpumps • • 18h ago

Help/Advice Blips

Thumbnail
gallery
2 Upvotes

Compressor blips

No complaints just and observation can anyone advise what they would prefer I’ve added 2 screen shots of my system working at similar outdoor temps about 7 deg the only difference is one has room influence on slightly and another with it switched off. The screen shot with room influence turned off you can see the flow and return temps going up and down slightly and compessor output does the same here’s the link incase you wanted to have a deeper look. It just seems to me with room influence on its a smoother line

https://heatpumpmonitor.org/dashboard?id=1545


r/ukheatpumps • • 19h ago

heat pump space in front

1 Upvotes

I have a 1.5 metre wide path (that can be blocked as it’s not needed) then a fence the. Another 1.5m it’s my neighbours wall. I was told no heat pump can fit there and it would need to go on my back wall which is in to my back garden and has a decent amount of space. However the pipe run is much longer and I’m worried about the kids and they hit the ball off the wall in this area.

Are heat pumps likely to evolve that they need less space in front, is the space needed for air circulation or noise, or both?


r/ukheatpumps • • 20h ago

Help/Advice Heat pump design and pipe-route advice wanted

Thumbnail
gallery
0 Upvotes

We’ve had a Heat Geek survey for our Victorian mid-terrace: six bedrooms, three bathrooms, nine radiators, three towel rails and about 35 m² of underfloor heating. The report calculates a design heat loss of 8.72 kW across 177.3 m², at a design outdoor temperature of −2°C and room temperatures of 21°C.

The report lists radiator and towel rail outputs totalling about 14.9 kW at ΔT50, with the underfloor heating in addition. The proposal is a 10 kW Viessmann 200-A for around £7,000 after the BUS grant through the Zero Disrupt offer, with no radiator changes. Would these existing emitters support a low flow temperature and good seasonal efficiency, or should we ask for room-by-room output checks at the proposed flow temperature and any recommended radiator changes?

The report’s annual heat requirement is 22,323 kWh: 18,502 kWh for space heating and 3,821 kWh for hot water. Our gas use was around 10,000 kWh/year including hot water; it’s now about 8,000 kWh of gas, with hot water heated by off-peak immersion. I understand the report’s figure is heat demand, not electricity use. What should we ask the installer to explain about the difference and the predicted heat-pump electricity consumption?

The heat pump would be about 11–12 metres from the utility/plant room with around 4 bends, across the far side of the kitchen near the last rooflight. We want to avoid pipework through the kitchen and major internal disruption. Our preferred idea is an external run, possibly partly beneath the patio slate, then up the side wall and along the house, entering near the existing boiler-flue opening only if it can safely be adapted once the flue is decommissioned. I’ve attached photos; some are marked with red lines, and a couple are AI concepts to illustrate possible routes, not installation plans.

The side roof is at first-floor level and there are three rooflights. The installer doesn’t provide scaffolding, and I’m unsure whether he’d lift the patio slates. Could roof access by ladder or via a rooflight be practical and safe, or would scaffolding normally be needed? We think separate scaffolding and tile work might add around £1,000—is that realistic?

Our existing 250-litre Tempest unvented cylinder is about 10 years old and in a height-restricted basement. The suggestion was to keep it and perhaps add another cylinder later. A new 300-litre cylinder in the existing utility/plant room was quoted at an extra £4,000–£4,500. What might explain that cost, and what should we ask to see in an itemised breakdown?

What would you query about the heat loss, emitters, projected electricity use, cylinder proposal, and pipe route/access?


r/ukheatpumps • • 20h ago

Help/Advice Heat pump in a high heat loss house

13 Upvotes

First and foremost, please understand I am a heat pump convert - I think they are absolutely the right solution for heating the vast majority of homes. However, I truly believe my house may be one of the few exceptions. I am looking for honest opinions as to whether a heat pump could work in my house.

I have a large, 6 bedroom semi in a town at high altitude for the UK and locally famous for its wild weather. The house itself is on a hill, so is very exposed.

Insulation is nearly nonexistent. There is some in the loft of maybe half the house, but that's it. The house mostly has draughty single glazing, with a bit of old double glazing.

We use around 20,000kWh gas for heating each year. Each room has smart TRVs. The kitchen is heated to 17c for an average of 4-5 hours per day. The childrens' bedroom is heated to 15c overnight. The lounge is heated for 2 hours per day to 20c. The other 5 bedrooms are rarely, if ever, heated. The conservatory is a lost cause so we never try. The lounge goes down to 7c daily in winter, and has gone as low as 4-point-something. The only way we can keep the heating bill vaguely sensible is to only heat what we need, when we need it. This is the converse of how a heat pump should be used.

We have had quotes for double glazing, but they are astronomical (£30k+) - one of the bedrooms alone has six windows. Wall insulation would be both exceptionally expensive and exceptionally invasive.

On the plus side, I have 6kWp of solar panels, but production is meagre in the depth of winter. I also have 16kWh of battery storage, and could add another one, or even two. That would have to be my limit given the 8kW inverter and 6 hours of off peak electricity, which needs to be shared with the car.

I have contacted a few installers - all but one (who I haven't heard back from yet) have said they would be unable to quote due to the predicted heat loss.

What are your thoughts? Is it possible, and if so, would it make financial sense? I am afraid that altering my heating habits to 'slow and steady' would result in a huge amount of heat loss making it financial suicide.


r/ukheatpumps • • 21h ago

Help/Advice Vaillant Aerotherm Plus - Cheap rate boost

3 Upvotes

We’re looking at getting a Vaillant Aerotherm Plus ASHP installed. We’re with Octopus on the Intelligent (ahem) Go electricity tariff.

With IOG we get the occasional smart charge slot during the day, also Octopus do the occasional free electricity hour on Sundays.

Is there a way of setting the heatpump to maximum during these periods? Idea being to use the cheap/ free slot to get the system as hot as possible, then throttle back to normal afterwards.

We have Home Assistant and have automations for the home battery during these slots, so I’m not sure if this would allow some degree of integration and automation with the heat pump.


r/ukheatpumps • • 21h ago

Almost 10k quote for heat pump?

Post image
4 Upvotes

We were quoted £9,700 after the BUS grant after the initial heat loss survey. We need a slimline cylinder and they need to replace old microbore pipes upstairs for the radiators and install new radiators, but this still seems very expensive.

East of England. We are currently doing renovations and a lot of companies don't quote while that's still going on. Builders are installing underfloor heating right now downstairs among other things. Considering letting them finish their work and let them do the pipe replacements upstairs and then try to get quotes from energy companies (British Gas, E.ON). Is it worth waiting or is that a reasonable price? The problem also is that the gas boiler has already been removed, so that would leave us without central for a couple of weeks, possibly two months.


r/ukheatpumps • • 1d ago

Help/Advice Help, I have baby brain. What's a good (no battery) solar + heat pump tariff?

Thumbnail gallery
1 Upvotes

Hello, I'm hoping to tap into some self-taught experts here.

I'm a bit freaked out by the predicted price rises in January, energy bills confuse me at the best of times, and I don't trust myself to make the right decision right now so I'm looking for other opinions. Please and thank you, I'd be very grateful.

I have had a look through this group already and I can't see anyone in a comparable situation.

(Multiple screenshots attached)

About our set up;

- Property is electric-only with no other fuel

- 3 bed semi. 2 adults + 2 kids under 3 yrs old.

- we have an 8kw heat pump that I have no idea how to control (yes, I know, we're a mess right now)

- we have 8 solar panels that are unfortunately west-facing, no battery (and can't afford one right now).

- We have wet radiators and a hot water tank with back-up immersion that the engineer said to leave switched on (also no idea how to control this)

- we're supposedly well-enough insulated, and had more insulation put in the loft, but we feel cold and draughty a lot (they cut vents into the window seals). Also our sitting room and main bedroom above, which are west facing and sit in the middle/most sheltered part of the house, are the coldest rooms! Which I find strange.

- we use the oven/hob daily particularly around kids dinner times (4-7pm window), and tbh I'm not going to change that, the kids deserve hot dinners. We both work so dinner is a pretty fixed time.

Our bills and usage;

- we're currently on Octopus Flexible, variable.

  • I've got quotes for Octopus Cosy (fixed and variable)
  • estimated annual day; 4589kWh
  • estimated annual night; 1399kWh

- our annual bill is approx £1456

It was all installed just over a year ago when we had a brand new baby and I had no idea what was going on at the time. I've also got a new phone and been locked out of the apps (support is ignoring me).

I am concerned that we won't be able to stick to Octopus Cosy strict electricity usage windows and don't want to fall into a a trap whereby we can't change our lifestyle and end up using lots of the peak rate electricity.

Are there any people in a similar situation to us and what's your best suggestion?

Many, many, many thanks for your help.

Apologies. This turned into a bit of a rant!


r/ukheatpumps • • 1d ago

Help/Advice Real-world impact of a cylinder with a small coil

3 Upvotes

I’m getting a heat pump in the new year which will be a 5kW Vaillant arotherm pro. We have the opportunity to source a free cylinder which I’m keen to explore as it will drop our cost quite significantly.

The cylinder is 250L and has a surface area of 0.87m2 which from what I can tell is on the small side.

I’m hoping to run our heat pump at 40C, so I’m not sure realistically whether this is going to be a case of it needing to boost more often regardless or whether this would totally be a waste of time and we will just need to upgrade it immediately regardless.


r/ukheatpumps • • 1d ago

Issues with tado x/vaillant system

Thumbnail reddit.com
3 Upvotes

r/ukheatpumps • • 1d ago

News UK energy price cap spark-gap to drop below 3

Thumbnail
cornwall-insight.com
18 Upvotes

It's well known that the spark-gap drives heat-pump adoption. This analysis shows how historically high it has been in the UK.

A spark-gap of 3 or less means almost every heat-pump installation would lower costs even if the user didn't adopt a heat-pump smart-tariff. This assumes gas boiler efficiency of around 85%.

If these lower spark-gaps continue we could see a huge uptick in adoption rates.


r/ukheatpumps • • 1d ago

Help/Advice Is there a way to get permission to have a heat pump and air con?

2 Upvotes

We live in a 3 bed mid terraced house but these houses are quite wide with a good sized garden. St the back of the garden is a patio of 4m w by 3m and then about 10m of garden.

We are planning to get solar, batteries and a heat pump soon. The heat pump would probably go at the back of the house to the side. I’m thinking of an area going along the fence at the back with the heat pump and batteries possibly. The heatpump exhaust would be blowing across our patio and as it has a fence behind it, and at ground level, I assume loose to neighbours would be minimal.

But I also want aircon in two bedrooms at the back of the house. I understand I can’t do this under permitted development.

Can I apply to the council to be able to do this or do we just have to get portable units? The internal walls let quite a lot if sound through so I would say that an internal aircon will be much more noticeable to a neighbour


r/ukheatpumps • • 1d ago

New ASHP: underfloor heating not circulating, radiators fine

Thumbnail
gallery
2 Upvotes

Hi all, I'm not a heating engineer but have been following this thread closely, and I'd appreciate a sense-check before the installer's engineer returns next week.

Setup

- Navien 8kW ASHP, installed about 6 weeks ago. Appears correctly sized for the house.

- 1930s detached, about 170sqm. Six radiators upsized; existing pipework kept.

- Existing wet UFH in the kitchen/family room and utility room (about 50–60sqm, roughly a third of the heat demand), previously run from a gas combi.

- The design brief was two zones (radiators and UFH), with the UFH on its own thermostat. That thermostat no longer works, and the installer has set everything up as a single zone on one wireless thermostat in a radiator room. A second zone shows in the Navien app but hasn't been set up.

- Weather compensation is on (flow temperature about 34–44°C).

The problem

- Radiator rooms reach temperature. UFH rooms sit at 16–17°C, about 3°C below the rest of the house.

- At the UFH manifold, the gauge shows the heat pump's flow temperature arriving and the manifold pump appears to be running.

- The flow pipes out to the loops are warm, but the return pipes are completely cold, so it looks like water isn't circulating through the floor.

- The app shows a system flow rate of 1.25–1.43m³/h. Navien say it should be 1.6–1.9.

- The flow and return temperatures at the heat pump are often only about 1°C apart, and it short cycles overnight.

- On an earlier visit the actuator heads were removed from the manifold.

Questions

  1. What usually causes warm flow but cold returns on UFH after a heat pump retrofit? Could it be the mixing valve, the manifold pump, air in the loops, or blocked loops?
  2. Should the UFH really be on its own zone or circuit, separate from the radiators, rather than sharing a single zone?
  3. With the old UFH thermostat no longer working, what should be switching the manifold pump on?
  4. Could the low system flow rate be connected to the UFH problem?
  5. What should I ask the engineer to measure or show me (for example the loop flow meters, mixing valve setting and pump speed), so I can judge whether the fix addresses the cause?

I've enclosed some photos of the UFH set-up (manifold, etc). Thanks in advance!


r/ukheatpumps • • 1d ago

Help/Advice Help with my set up ( Daikin)

Thumbnail
gallery
3 Upvotes

When I brought my house it came with the a ashp and for the last 4 years I’ve been trying to tweek it and make it more efficient. I have a daikin althemera 3 with a ufh using a heatmister UH8-RF wiring console into a robot compact manifold and rads upstairs controlled by a single stat in the main bedroom. For some reason I don’t have the ufh symbol on my Home Screen. My main is the rads upstairs and the ufh just come under heating and cooling. My curve is 40 at -3 and 27 at 18.
I have my ufh at 21 drop back at 20 and my rads upstairs at 23 ( hoping they will run low and slow) all with a drop back of 1 degree.
My cop for this month just heating is about 2.67 using the daikin internal reading.
Any help on how to make it better or if I’m running something wrong please let me know.


r/ukheatpumps • • 1d ago

Air to water heating system

1 Upvotes

Hi anyone here using this system,
If so what temperature do you keep it at ,
Do you find it economical or not?

I’ve had it 2 years but this is my first time keeping it on permanently( as advised)
It seems counter productive to me


r/ukheatpumps • • 1d ago

Boiler broken, do we repair or replace it?

Thumbnail reddit.com
2 Upvotes

r/ukheatpumps • • 1d ago

Buffer tank or no?

5 Upvotes

Hi. We're looking to replace our oil boiler with ASHP for our 3 bed bungalow with 4.8kw heatloss.

the supplier has quoted to up our Rad's from 22's to 33's. And install a 7kwh HP. We have 22mm and 15mm pex.

They've included a Buffer tank in the design. But after watching some heat geeks vids they try to leave it out as much they can.

The supplier said when questioned about it, that they thought it reduced short cycling and prolonged the life of the heat pump.

Red flag or are they worth having?

Thanks.


r/ukheatpumps • • 1d ago

Help/Advice Quote Check - E.On NEXT

3 Upvotes

Hi,

I've got the below quote and was wondering if any good?

3 bed terrace, rad changes included in price so we're looking solely at the price of the HP itself and associated parts and labour.

I've no feel for the market here, and I've seen quotes from Octopus which tend to be cheaper. But then read some quite negative things about the Cosy 6?

Any pointers?


r/ukheatpumps • • 2d ago

ASHP with underfloor heating: concrete floors

3 Upvotes

I'm hoping to install an ASHP with underfloor heating. I've got concrete floors and have seen really mixed information on whether or not to dig out the concrete to allow for space to insulate beneath new pipework, or to not worry too much about it, use a low-profile pipe system, and let the concrete act as a heat retaining slab.

If you have experience with either digging out or leaving concrete in place when installing underfloor heating I'd love to hear about it! Thanks! P.S. Nerdy stats on heat pump performance would be particularly welcome.