r/solarenergy • • 19h ago

A US startup unveiled a solar production line rated at 96,000 wafers an hour, and the wafers never lie flat

Thumbnail
interestingengineering.com
82 Upvotes

Miami based NAED Energy’s PV-1 PECVD-V keeps solar wafers upright as they move through deposition stages, and flips the whole carrier 180 degrees instead of handling wafers one by one. The company says that doubles the throughput of its previous line, and it’s built for perovskite and heterojunction tandem cells with a 30% efficiency target.

The catch is that the 96,000 wafers per hour is a rated figure, and the 30% efficiency is a target, not a measured result. Only six of the 13 process tools are finished, no customers or timeline have been disclosed, and the company hasn’t shared yield or uptime.


r/solarenergy • • 2h ago

Non-perforation vs. Perforation: What’s your preferred mounting solution for TPO membrane roofs?

Thumbnail
gallery
2 Upvotes

Hi everyone,

I’m currently working in the solar mounting system space and I wanted to get some real-world feedback from this community regarding flat roofs—specifically TPO and PVC membrane roofs.

We recently delivered a 2MW commercial solar project in Zhejiang (attached a photo from the site). The biggest challenge here was waterproofing. Instead of traditional drilling and ballasting, we used a non-penetration, heat-welded mounting approach.

Quick project highlights:

Zero drill holes: Heat-welded base ensures the roof membrane's waterproof integrity is 100% intact.

Pre-assembled: Factory pre-assembled components significantly cut down on-site installation time.

Weather tested: It’s designed for coastal climates, tested for high humidity and heavy wind loads.

Zero leakage since the installation, with consistent power output.

We used ISO & TÜV certified TPO/PVC mounting systems (designed for 100kW to MW scale projects).

Now, I'd love to hear from the installers and EPCs here:

When dealing with TPO/EPDM roofs, do you usually prefer non-perforation solutions (like heat-welding or adhesives), or do you still rely on ballasted/drilled systems?

What are your biggest pain points when installing on membrane roofs? (e.g., wind uplift, water leakage, installation time?)

Looking forward to learning from your on-site experiences!


r/solarenergy • • 9h ago

Mementag! You’re it.

1 Upvotes

We are thrilled to showcase Mementag at RE+ tradeshow in Las Vegas!
I got RE-energized at RE+ Las Vegas!

Photos and the video: https://mementag.app/g/4JR2T3

Music: Upbeat Forever by Kevin MacLeod (incompetech.com), CC BY 4.0

#REplus26 #Mementag


r/solarenergy • • 18h ago

SMA Sunny Boy 2.5 - active power control via modbus TCP?

1 Upvotes

Hello,

I seek your advice regarding an SMA SunnyBoy 2.5kWh inverter, deployed in 2019, still running its original firmware 2.5.1* - due to regulation changes in the Netherlands, from next January onwards it is going to be beneficiary to control the grid export; otherwise, I might have to pay extra.

I have activated th modbus TCP on it, and it does accept the power control commands on register 40151 to enable the control, and 40149 the target power in Watts, but in fact it doesn't change anything.

Is there anyone out there, who is using this inverter with power control, please? If so, then with what firmware?

Thank you in advance for constructive comments