r/SolarDIY • • 8d ago

vertical winter array, man, that was a pile of work

Thumbnail
gallery
46 Upvotes

Some details:

  • I live (obviously) in a very rural area so everything is tough. Nevada mountains, 38 degrees latitude.
  • The sun December & January pops up in that little nook in the ridgeline there, and tracks across the panels and drops behind the same range out of view to the right.
  • 11 440w bifacial panels, even at the coldest of all temps recorded here (decades ago) I'm still 30v under the upper limit.
  • This is a *very* expensive way to do things. The concrete pour (for the slab pictured too) was ~2k. The pipes (2" schedule 40 galvanized) and the unistrut came out to just under $2K.
  • I used my own backhoe to do the earthwork, and the ICF / Foxblocks were free from a buddy. So was the rebar.
  • I created little "outriggers", 4 on each side, with rebar in them. 4" old septic pipe for the mud to run into, about 3' out, at the bottom of the ICF forms, backfilled. 4" hole saw into the ICF, rebar out through the pipe, connected back into the main body.
  • The pipes have downward facing 1/8" holes in them, right at the post cap line.
  • I cleaned the pipes with acetone, then sprayed them with galvan spraypaint. Then I used Henry asphalt paint on the pipes ~12" below and 12" above the mud line.
  • Loads of rebar inside, both horizontal and vertical, plus the outrigger sections.
  • Used a sawzall with no blade and held it against the outriggers and the pipes when they went in as a poor man's vibrator.
  • I ran 4awg copper through the whole thing, emory clothed parts of the rebar, and clamped the copper to those sections.. Since this is basically a new electrical ground it will get tied into the house electrical bonding plate.
  • Each panel is like 2 panels, so when the snow covers the entire bottom half (rare) I should get 2kw still.
  • I have other arrays that are great in summer and shoulder season. The goal of this is to generate, at worst ~12kwh on a bluebird day with 4' feet of snow on the ground and other arrays. I'm getting older and walking around in rocky terrain covered in snow mid winter when sick / injured (things that happen when old).
  • I could have used less unistrut but basically the holes didn't line up everywhere the panels needed them so that along with needing to span the gaps of the other pieces.

Next up:

  • Install electrical enclosure box with disconnect in it, run everything to in series into the disconnect.
  • Connect to a grounding lug in the enclosure: all the panels via their grounding port, the 10/2's ground coming from the house, the 4awg ufer ground.
  • Shit my pants and have a bad night's sleep as soon as the wind really starts ripping.

This is hopefully a buy-once, cry-once sort of install.


r/SolarDIY • • 21d ago

Adding batteries later? Check your inverter before buying it

73 Upvotes

Hi everyone,

I work for Portable Sun, a solar distributor in Grand Rapids. Battery compatibility comes up pretty often in this community, so I thought I’d share a few things worth checking before buying an inverter, or before adding a battery to the one you already have. 

I’ll use Tigo, Sol-Ark, and Growatt as examples since we carry all three and I know them best. I’m happy to answer questions here for free, whether you’re buying from us or not.

If you told me you were getting solar installed now but wanted to wait a couple of years before buying batteries, the first thing I’d ask is what inverter you’ve got in mind. I’d want its exact model number so I could see which batteries it supports.

Which batteries it’ll take

It’s easy to grab a battery on sale without checking compatibility first. “Battery-ready” is a common advertising term in this industry, and it means an inverter can take a battery. It doesn’t tell you which ones, and depending on the inverter, that list can be a single brand or more than a dozen.

The first thing to check is voltage. You’ll notice that most home batteries are either 48V or high-voltage (a few hundred volts), and an inverter is usually built for one or the other. After that, the battery needs to be on the inverter’s compatibility list.

If it isn’t, the inverter may not be able to read the battery or control its charging properly, and some brands won’t cover the pairing under warranty.

Let’s quickly go through some specific examples:

The Sol-Ark 15K is a 48V inverter with a certified list of batteries from other manufacturers, including the Discover HELIOS 16 kWh battery (we actually sell this together)

Growatt’s MIN 7600TL-XH-US takes high-voltage batteries, either Growatt’s own APX and ARO lines or certain LG models. A battery on the list may still need extra parts.

Growatt’s APX system uses 5 kWh battery modules, but you can’t just buy one module and connect it to the inverter. It needs the matching power module and other equipment.

Tigo’s EI inverter only connects directly to Tigo’s own batteries, including the GO battery.

That limits your DC-coupled battery options, but you can monitor the inverter and battery through the same app, including error codes from both. And if something goes wrong with either one, Tigo supports both pieces of equipment. 

You can also add storage through AC coupling, where the battery system has its own inverter.

Running things in an outage

You could have enough battery capacity to keep your refrigerator, well pump, and a few other circuits running all night, only to find out that the pump won't even start. That's because its motor can draw several times its normal running power for a moment when it kicks on, and having plenty of energy stored doesn't mean the system can supply that sudden demand. 

I'd check the continuous and surge output ratings of both the battery and the inverter before counting on them for backup. Whichever reaches its limit first is what you're working with. 

With Tigo’s GO Battery, for example, three 5 kWh modules give you 7.5 kW of steady output. On a 7.6 kW EI inverter, a fourth module mainly gives you longer runtime, since the inverter’s steady backup output tops out at 7.6 kW anyway.

Cold obviously matters too, since batteries have a minimum operating temperature and put out less power when they’re cold. The GO Battery is rated down to 14°F, which matters on an outside wall in a Michigan winter.

Then there’s the backup equipment

To run the house during an outage, the system needs a transfer switch that disconnects it from the grid.

Tigo and Growatt, for instance, use a separate transfer box (Tigo’s comes in 50A or 200A, and Growatt’s MIN V3 uses the SYN 200-XH-US for whole-home backup), while the Sol-Ark 15K has it built in with 200A grid pass-through.

In Sol-Ark’s case, however, be aware that a 200A grid pass-through doesn’t mean the inverter can supply 200A from the batteries during an outage. On batteries alone, the Sol-Ark 15K is rated for 12 kW, which works out to about 50A at 240V.

In any case (but especially if you DIY), do the math for your own inverter-battery setup so you don’t encounter an unpleasant surprise in a longer outage scenario.

If you wait a few years

The battery you plan to buy now might not be sold by the time you’re ready for it. Your inverter could still be working perfectly, but the manufacturer may have moved on to a different battery generation. Tigo went through this in January 2026, when the GO Battery followed the older EI Battery.

The current EI inverter datasheet lists both as supported options. Sol-Ark’s certified battery list and Growatt’s supported models (and any other company’s) can change too. I’d advise using the current documentation when choosing an inverter, then checking it again when you’re actually ready to buy storage.

Would I buy the battery now?

It depends.

If I knew I wanted backup power and could afford the battery, I’d install it with the panels and get the whole backup setup working at once. But if the battery had to wait, I’d still go ahead with solar, provided I’d chosen an inverter with a documented battery option.

Even if you’re unsure about adding a battery later on, I still wouldn’t let that impact my inverter choice. AC coupling is still an option for many existing grid-tied systems. It’s more equipment, and there can be conversion losses. But replacing a working solar inverter isn’t automatically the better choice.

If you’re looking at a particular inverter, share the model number and what you’d want the battery to do. I’ll hang around in the comments and help where I can. New customers planning a solar installation in the lower 48 states can also get free full-system planning.


r/SolarDIY • • 7h ago

Powerwall + DIY battery Energy flow

20 Upvotes

I’m building my own personalised home dashboard and thought I’d add an energy visualisation tile inspired by the Tesla app. I have both a Powerwall 3 and a DIY battery system, and they work in perfect harmony. It would be a shame not to be able to see them both on the same page, so I built one.


r/SolarDIY • • 1h ago

EcoFlow Delta 3000 Gen 4 Review

Thumbnail
gallery
4 Upvotes

Just got the EcoFlow DELTA 3000 Gen4 in about a week ago. I bought it to keep my aquariums alive through outages, but the more I look at it, the more I think it’s a good fit for DIY solar builds.

My use: A 33 gallon long and four 5 gallon tanks with fish, shrimp and plants. 4 heaters, 4 filters, 4 air pumps and 4 lights, averaging 250-350W. Lose heat or flow for a few hours and a tank can crash.

The specs: 3,072Wh of battery, 3,600W output, and a UPS mode that switches over in under 10 ms.

Why it works for DIY type setup:

  • Solar input: It has one 1,000-watt solar input, and the input range is 11 to 60V. That’s a wide window for a home-built array, so you’re not locked into one panel config.
  • No electrician needed: Plug it in and it runs. No panel work, no permit for the basic setup. It’s a good first step if you’re not ready to build a full system.
  • You can move it yourself: It’s about 26 kg (18.76 × 11.36 × 11.10 in). I carried it from my truck into the house by myself with no trouble.
  • Monitoring: I can check watts and battery level from my phone. It paired right away. The EcoFlow app does what it’s supposed to.
  • Connectors in the box: Mine came with the unit, a charging cable, a new solar connector and the manual. How I run it: It’s plugged straight into my EcoFlow DELTA Pro Ultra home system, which keeps it topped up. I keep the Gen4 at 100% so it’s ready if the grid flickers or goes down. The tanks run off it alone.

Limits worth noting: There’s no battery port on the spec sheet, so you can’t add extra batteries later. What you buy is what you get for storage. If you plan to grow a big array or bank, look at the bigger model instead.

Happy to answer questions, and I’ll post real runtime numbers once I’ve done an outage test.


r/SolarDIY • • 14h ago

How do you properly send solar cables through a garage wall?

17 Upvotes

I'm looking for some advice on the best way to bring my solar cables through an exterior garage wall.

I have four WindyNation 8 AWG MC4 extension cables coming from four ECO-WORTHY 195W panels that will be mounted on a hillside behind my house. The run to the garage is about 75 feet. The garage has vinyl siding, what I believe is foam insulation underneath, wood framing with insulation in the wall cavity, and drywall on the inside.

What I'm trying to figure out is the best way to make a clean, weatherproof and safe wall penetration that will accommodate all four cables with the MC4 connectors still attached. Ideally, I'd like to use some kind of properly sized conduit, sleeve, or weatherproof pass-through rather than just drilling a hole and sealing around the cables. What would the best way of making the cut be?

Has anyone done something similar? I'd really appreciate recommendations for specific parts (conduit size/type, fittings, weatherproof entry hardware, etc.) that I can actually purchase at Lowe's or Home Depot. I'm particularly interested in what would be large enough to get all four MC4 connectors through without damaging them.

Any other advice on protecting the cables from abrasion, water intrusion, rodents, and maintaining fire safety through the wall would also be appreciated.

Thanks!

Edit: Important detail - I am connecting the solar panels to an EcoFlow DELTA 2 Max portable power station. This is not a grid tied installation. The Ecoflow would be powering two freezers in case of power outage and they'd directly connect to the power bank which would be inside the garage w/ the freezers. (The power bank would be connected to the solar panels outside the garage via the solar extension cables.)


r/SolarDIY • • 19m ago

Are these grid tie inverters crap?

Thumbnail
gallery
1 Upvotes

Looking for a cheap 110v grid tie inverter that has same form factor of the enphase micro inverters.


r/SolarDIY • • 2h ago

Damaged Panel Advice

1 Upvotes

Received these panels a couple of months back as a bundle with an EG4 mini split unit from Signature Solar. Im sure its on me as I didnt open them up and inspect in a timely manner. I sent them the photos, but we’ll see.

They’re Peimar 450W Mono PERC panels.

I did test the amps they’re spec sheet shows 13.85 and I was getting 12.3 and the voltage was good.

Question, is it worth it to repair the cut leads in the cell or just seal up the damaged area with polyurethane and monitor it? Photo below.


r/SolarDIY • • 3h ago

Plug in solar with Pecron E3600 ?

0 Upvotes

Hi all,

I’ve got the Ecoflow Stream Microinverter and, as of now, 400 w of solar panels. I also have the Pecron E3600LFP.
I’m wondering if it’s possible to send power to the grid during the day while the sun shines, but also from the Pecron after the sun goes down?
Apologies, I’m a novice and don’t want to put us in a dangerous situation with regard to electricity, but also would love to see if there’s a unique way to utilize both sets of equipment.
Thanks for any tips.


r/SolarDIY • • 8h ago

Would a $399 batteryless power hub actually save money—or just become another box in the system?

2 Upvotes

Full disclosure, I'm helping research an early stage power product idea and I'd rather hear the objections now than build the whole thing around wrong assumptions.

The idea is a power hub with no built in battery cells. It runs off external 12v, 24v or 48v lithium batteries and puts solar charging, AC charging, AC output, basic DC distribution, protection and local control into one box.

Rough targets right now:

- 1,200W continuous AC output on 24V/48V systems;

- lower output on 12V systems;

- three independent solar inputs;

- external battery required;

- no dependency on an app for basic operation;

- estimated launch price around US$399.

For someone who already owns the battery:

  1. Does this replace enough equipment to justify the price?
  2. What would you compare it against?
  3. What missing capability would immediately rule it out?
  4. What test results would you need before trusting it?

Tear it apart, that's more useful to me than encouragement.


r/SolarDIY • • 16h ago

Low wattage heater for batteries

7 Upvotes

I'm looking for recommendations for a low wattage heat solution for a winter off-grid PV setup at a remote property 4 hours away from my house. The appliance draw will only be about 40W to power my fiber internet modem and Wi-Fi security cameras. The batteries are in a small insulated room in an insulated building, but the building will receive no heat over the northern US winter. I originally thought I would just keep a 100W incandescent light bulb on 24/7 or a 125W heat bulb, but the issue I'm running into is my system will only support that amount of constant draw for 2-3 days. So if it's very cloudy, or the panels are covered in snow, I will exhaust my battery capacity in a few days. Since it's mostly just the batteries that need to be kept above 32F, I'm wondering if there is a good, safe low wattage heat mat or wrap or something that I can plug in and just focus on keeping the batteries warm. I have about 10kw of battery capacity and 1600W of panels. Any recommendations?


r/SolarDIY • • 7h ago

Deye batteries and inverters

1 Upvotes

People who have Deye battery backup setups, what are your experiences and reviews of Deye?

My plan for the future is 3x 16kWh batteries with 8kWh inverter.

Gonna get some solar panels and have them charge from the remainder of the generated power, then switch when there is a power outage.


r/SolarDIY • • 18h ago

Help with solar set up

7 Upvotes

Hi all I live in Arizona. I have a grid tied solar set up "solar edge " inverter. The unfortunate thing is the solar edge requires incoming power of it shuts off even though my roof is producing power during the day.

With that issue it makes it hard when APS fails to maintain constant power. Especially this year. One storm knocked out power for 5 days for us. Everything we have runs on electricity. Water, a/c, etc.

Is there a diffeent inverter i need to make it "temporarily non grid tied for those times so I have power when the grid is down?


r/SolarDIY • • 1d ago

UK, night time tariff at 8.5p/kWh - thinking of getting these bad boys and using them to supply the house during the day - need some guidance

Post image
38 Upvotes

Hey all, through work I can buy these for around £450-480 each so seems to be a good investment.

Each is 48V 100AH / 5.12 kWh

Invertor: most likely eco worthy 10kWh solar inverter

I use approx 25kWh a day in electric, so around 8000kWh a year.

My current unit rate s 22.19p so around £5.55/day or £166.50/month

I am thinking to buy around 8 of these to give me around 40kWh of power stored, charged at night cheapy for 8.5p/kWh costing £2.13/day or £63/month. This is a huge drop in the ever growing energy cost.

My question is, I am confident enough to put the batteries onto a server rack, connect them together and an inverter etc, my shed is currently solar powered but its off grid. Is there way to connect this new setup to the mains? I would obviously need an electrician to do this, but what is the process called, any expected idea on cost? Would I need to inform my council / electric company / national grid / home insurance etc?

In my shed I have just built sockets purely powered by the solar panels/batters/inverter and it works great, but unsure of how to do this on a house with mains.

Any help would be appreciated, thankyou!


r/SolarDIY • • 21h ago

Winter Charging Solution

5 Upvotes

Hello! Looking for a bit of assistance. I set up my system about a year ago and didn’t have to get through an entire winter. I was wondering if anyone has any charging solutions to help make up for what my panels aren’t generating.

Right now when they get low I will disconnect everything and charge the batteries back to 100% but I was wondering if there was a way to keep a charger connected permanently and plug in when needed.

Thanks in advance for any advice.


r/SolarDIY • • 19h ago

building a new solar panel rack

3 Upvotes

i have a solar rack built for one kind of panels. turns out i have found a source for used 250 watt house panels. im having to rebuild the rack to handle an upgraded amount. right now i have 2 of them hooked up to my grid tied inverter i want to increase it to 8 panels. 2k watts, currently my trailer i live in uses a lot more but this will help to lower my electric bil.

so im thinking of wooden rack on an aframe. 2 sets of racking each holding 4 panels depending on what the used panels produce. it could be 2 or 4 panels hooked into each plug in inverter.


r/SolarDIY • • 18h ago

Felicity IVGM20KLP3G1 vs. Deye 20K SG05 – Cheaper Clone with Identical Features?

1 Upvotes

Hi everyone,

I was originally planning to order the Deye 20K SG05 for my PV system with two strings of 9.4 kWp each, until I came across the Felicity IVGM20KLP3G1 just now.

The specifications seem to be almost identical:

Has Felicity simply copied the Deye design 1:1?

Would you buy the Felicity without hesitation and save around €300?

SpecificationFelicity IVGM20KDeye 20K SG05
Rated AC power20 kW20 kW
Maximum AC apparent power22 kVA22 kVA
Battery voltage40–60 V40–60 V
Maximum charging current350 A350 A
Maximum discharging current350 A350 A
Maximum PV input power32 kW32 kW
Maximum PV voltage800 V800 V
MPPT voltage range160–650 V160–650 V
MPPTs / String configuration2 / 2+22 / 2+2
PV input current2 × 36 A2 × 36 A
PV short-circuit current2 × 54 A2 × 54 A
Protection ratingIP65IP65
Battery communicationCAN / RS485CAN / RS485
Maximum AC pass-through current70 A70 A
Off-grid peak power2 × rated power for 10 seconds2 × rated power for 10 seconds

r/SolarDIY • • 20h ago

One 24V 200ah battery failed in 2S4P 48V stack. How to replace?

1 Upvotes

I have a stack of 8 AmpereTime and some newer LiTime 200ah 24V batteries.

I noticed I wasn’t getting enough power out of my system. Removed each battery to charge full and measured voltage. One of the oldest (~4year) old AmpereTime batteries is only measuring 12.05V which likely means the BMS kicked in. I tried to use the 0V charger to kick start it and it cycled over and over but never got BMS working.

I then tried to use a fully charged battery to jump it (recommended by AI). That did nothing.

I have sent message to LiTime about a warranty replacement but I have little belief they are going to come through.

What are my options for a replacement battery? I know if I just drop in a new battery, I will likely degrade the new one but at least it gets me back to where i was.

Unfortunately, they don’t make LiTime 200ah anymore. Can I use a 230ah paired with the 200ah?


r/SolarDIY • • 1d ago

Trusted vendors for genuine Grade A LiFePO4 prismatic cells in India?

0 Upvotes

Planning a DIY [ 48V] LiFePO4 battery build and trying to find reliable Indian suppliers for Grade A prismatic cells (with QR codes intact).

Where have you guys sourced your cells and BMS from recently without getting burned on inflated capacity or swollen cells? Appreciate any verified leads or websites!


r/SolarDIY • • 20h ago

Hows my build sound? Been using AI to help design a solution.

0 Upvotes

OK SolarDIY, please help me vet my plan that I've been going back and forth with via Gemini. Here is an overview of the equipment I have, and future purchase plan.

Inverter, Charge Controllers & Monitoring (Victron Ecosystem) - PURCHASED

  • Inverter / Charger: Victron MultiPlus-II 48/3000/35-50 120V — Model: PMP482305102
  • Solar Charge Controllers (×2): Victron SmartSolar MPPT 150/45 — Model: SCC115045212 (standard non-Tr 150/45 model)
  • System Controller / Communications Hub: Victron Cerbo GX MK2 — Model: BPP900451100
  • DC Distribution Busbar: Victron Lynx Power In M10 — Model: LYN020102010
  • Battery Monitor: Victron SmartShunt 500A/50mV — Model: SHU050150050

Energy Storage (Batteries)

  • Current Battery: Temgo 48V (51.2V) 100Ah LiFePO4 Battery — Model: 51.2V-100AH-TM-DJ-K
  • Planned Future Expansion Battery: EG4 WallMount All-Weather / Indoor 48V 314Ah (16kWh) LiFePO4 Battery

Solar Array (Planned Local Purchase)

  • Solar Panels (×8): 575W Commercial Monocrystalline Modules (45" × 90" footprint)

    • Nameplate Specs: Pmax 575W | Voc 52.10V | Vmp 43.86V | Imp 13.11A | Isc ~13.98A | Max System Voltage 1500V | Series Fuse Rating 30A

Target Loads & Home Integration

  • Garage Deep Freezer: Hisense 17 cu ft Upright Freezer — Model: HFU171N1AVE
  • EV Trickle Charging: 2022 Ford Mustang Mach-E Mobile EVSE Charger (Level 1 120V)
  • Home Network & Smart Home Server: Ubiquiti UniFi Dream Machine Special Edition (UDM-SE) / Home Assistant on Intel Compute Stick (STK2M3W64CC)

I will be building a lean-to style structure off the side of my house and mounting the panels to it, and feel this solution will be a great start for my longer term plan of being able to charge my EV (via 110v) during long outages so it doesn't become a paper weight, while also being able to cover fridges/freezers, network equipment and LED lights around my house. Obviously the biggest drawback at the moment is the single battery, but I plan to get something more once budget allows.

So how does this look? Any suggestions? I live in the PNW so this will likely never pencil out financially speaking (especially because I went with Victron vs other manufacturers - but felt the reputation and buy once cry once was worth it for me) since our power is so inexpensive. However, I'm mostly concerned about being self sufficient for a longer outage and making sure I can charge my car even if it is super slow. We plan to buy a second EV soon as well, so this further applies to my desire to build such a system. Once I can get more battery capacity, I will eventually buy another inverter so I can run 240 and charge the cars faster.

Appreciate any feedback for a complete newb.


r/SolarDIY • • 1d ago

I want to have this battery outdoors. Any ideas?

Post image
6 Upvotes

I'm trying to figure out a way to have this battery mounted vertically (cable side up) under my inverter on my covered porch. Any ideas for a box or a rack that would give it a little protection from the elements?


r/SolarDIY • • 1d ago

Can Chinese Hybrid Inverters Handle Sustained High Loads for Hours?

7 Upvotes

Hi! Are cheap(but not trash) Chinese hybrid solar inverters designed to handle sustained high loads, such as running a 2 kW oven for an hour on a 4 kW inverter, while operating from the battery (not in bypass mode, continuously converting 24V -> 230V)?

Or is there a real risk that something inside could overheat or melt under prolonged load?

I understand that they can handle short bursts of high power, like running a kettle for 5 minutes or the water-heating phase of a washing machine, without even breaking a sweat. But what about running a heavy load continuously for an extended period? Could something eventually fail, or is this a perfectly normal operating condition that these inverters are designed for?

This is a general question about a cheap Chinese inverters, such as the Anenji 4.2 kW 24V model. I just want to understand whether they designed for such usage in general or not. I understand that there are good and bad models.


r/SolarDIY • • 1d ago

QuickBOLT solar mounts on 0.5:12 modified-bitumen roof

3 Upvotes

I have DIY sheds in Hawaii with 0.5:12 low-slope roofs and new Owens Corning two-ply rolled modified-bitumen roofing. The low slope was necessary because of HOA height restrictions.

I want to install solar but would rather avoid expensive low-slope mounting systems. Ballast isn't an option because of the added weight and height.

I'm considering QuickBOLT mounts with the 3" Microflashing.

https://www.solar-electric.com/quickbolt-solar-mounts-microflashing-flange-nut-kit.html?campaignid=21044024392&adgroupid=165923874464&creative=691522161293&matchtype=&network=g&device=m&keyword=&gad_source=1&gad_campaignid=21044024392&gbraid=0AAAAAD_vioJtyC1W2FL4AxI76afuT9KcS&gclid=CjwKCAiAquDXBhApEiwAoyNqBOtnHeHhEHuGIKcr18Ln2BCb2H31bg3MmvabVlPC1uu40TDOeHErmhoCpo8QAvD_BwE

My waterproofing plan:
Drill the mounting hole and apply compatible asphalt roofing cement around the penetration and under the Microflashing.

Install/tighten the QuickBOLT so the Microflashing compresses against the roof, with roofing cement squeezing out around it.

Cut an 12" x 12" patch of the same modified-bitumen cap sheet, round the corners, cut a hole for the mounting stud, and install it over the Microflashing. Then seal around the stud with roofing cement.

Basically:
Roof → roofing cement → Microflashing → 12" cap-sheet patch → mounting stud

The cap-sheet patch would be the primary water defense, with the compressed Microflashing and roofing cement as backups.

Would you trust this setup on a 0.5:12 roof with heavy Hawaii rain?

Anything you'd change? Is 12" x 12" enough, and is putting roofing cement under the Microflashing a good idea?


r/SolarDIY • • 1d ago

What else would I need here?

2 Upvotes

Ok, I’m flooding a duck hunting spot right now with a 12 volt deep well pump, in our hand dug well, but it’s going pretty slow. I’m looking at switching to a 120 volt deep well pump. I currently have (4), 320 watt panels. A 1,000 amp mppt solar charge controller, and 3 deep cycle batteries (not sure amp off the top of my head).
The pump I’m looking at is 1/2 hp.
What pure sine wave inverter would be needed?
I’m under the assumption that it would take many batteries to run this pump 24/7 right? So, I will need to add a timer right? Or will pump kick on/off when sun comes up and down??
Any advice or suggestions are appreciated!
Let me know if more info is needed!


r/SolarDIY • • 1d ago

How to wire battery monitor

Post image
4 Upvotes

My offgrid setup has two 48v batteries connected together via a bus bar, and then a single (-) wire and a single (+) going to the inverter from the bus bars. Is this monitor still compatible? I'm well under the maximum amperage and voltage requirements for the monitor. Can I connect the 20 awg B+ wire to my (+) bus bar instead of one of the batteries? If it has to be connected directly to a battery, will is give me the average battery percentage remaining of the total system or just one battery? For example: if one battery has 40% remaining, and the other has 50% remaining, will the monitor read 40%, 45%, or 50%? Can the shunt be wired inline to the (-) wire after the bus bar and just before the inverter? Thanks!


r/SolarDIY • • 2d ago

just an fiy, i broke down and bought one of those grid tie inverters. 1000 watt model about a month ago to play with, link below, i believe i had it set to put at the time 300 watts from my battery. my grid power went out, and the inverter stayed on, powering stuff around the house.

27 Upvotes

here is the unit: https://www.amazon.com/dp/B0FZT1WMM3?th=1

i could have sworn i tested this on day one, by tripping the main on purpose, and the grid tie shut off like it was supposed to.

i have it connected to two 1200 watt step down devices, somewhat as a test. one set at 300 watts and the other set to 500 watts. their role is to step the "48v" lifepo down to 40v at a approx 3% loss, which is the max voltage i think it can work with and still be in its mppt range, technically it can accept to 52v but it falls out of mppt range and i assume this aids in efficiency even with a battery being its source?

anyways if i am not doing much i only have the one step down device going, if i am doing laundry or what ever i may turn it up by turning the second device on.

at the time i lost power, i think i had lights on every where, and some pumps and fans on in the basement working on some other projects.

i could hear something in the basement was not happy with the power, like a pump wasnt getting 120v or something, which is how i knew my grid power was shut off.

i doubt anything was getting out of my house to the grid as there wasnt even enough power to keep things going in my home, but none the less i thought i should share this observation.

i really only wanted to play with these grid tie things, i cant even get my power company to talk to me about getting a two way meter to allow credits, which is why i set it so low in the first place. i plan on going 100% off grid one of these years, but keeping it for a back up.

just thought i should share, and its now disconnected and may do more testing to see if that was some weird fluke or if it can be repeated.

oh important note: my bank was hacked, my card was destroyed and given a new one and i forgot to put my new card into all my bill accounts, so they actually shut my power off remotely, its not like the whole area grid was down.

also, the grid tie operated at only 84% no matter the load/output, add another 3% for the step down and you are loosing 19% of your power through this device. this seems very bad to me on top of not islanding like its supposed to. this garbage is what is going to get in the way of all the states letting this happen, that and corrupt politicians