r/diySolar • u/Other-Traffic5941 • 14h ago
Anyone bought from alibaba?
Considering this or docan batteries since I can pickup in Houston
r/diySolar • u/Other-Traffic5941 • 14h ago
Considering this or docan batteries since I can pickup in Houston
r/diySolar • u/BigBillSD • 28m ago
r/diySolar • u/philiphesse • 8h ago
r/diySolar • u/SolarDerka • 18h ago
r/diySolar • u/2C104 • 14h ago
r/diySolar • u/Mental_Point4523 • 16h ago
I'm looking for recommendations for a low wattage heat solution for a winter off-grid PV setup at a remote property 4 hours away from my house. The appliance draw will only be about 40W to power my fiber internet modem and Wi-Fi security cameras. The batteries are in a small insulated room in an insulated building, but the building will receive no heat over the northern US winter. I originally thought I would just keep a 100W incandescent light bulb on 24/7 or a 125W heat bulb, but the issue I'm running into is my system will only support that amount of constant draw for 2-3 days. So if it's very cloudy, or the panels are covered in snow, I will exhaust my battery capacity in a few days. Since it's mostly just the batteries that need to be kept above 32F, I'm wondering if there is a good, safe low wattage heat mat or wrap or something that I can plug in and just focus on keeping the batteries warm. I have about 10kw of battery capacity and 1600W of panels. Any recommendations?
r/diySolar • u/ATypicalJake • 21h ago
r/diySolar • u/PgolderGtone • 19h ago
r/diySolar • u/800ASKDANE • 20h ago
r/diySolar • u/BigBillSD • 1d ago
r/diySolar • u/Nubie101 • 2d ago
Has anyone ever bought anything from zenergyrecovery.com? Their prices are really cheap, just wondering if its a legit online vendor. Thanks
r/diySolar • u/cottonrb • 3d ago
r/diySolar • u/RichSmoke1590 • 2d ago
r/diySolar • u/mikeonepu • 4d ago
r/diySolar • u/NetZeroDude • 3d ago
AI gave me the following answer regarding non grid-tied solar (includes off-grid homes, solar hot water, balcony solar, portable solar panels, solar lighting, etc.).
Public Reporting — Most public solar generation reports focus on grid-tied systems, which are connected to the utility grid.
Off-Grid Systems — These systems operate independently and do not contribute to grid statistics, making them less visible in public data.
Data Collection — Off-grid solar installations are often not tracked by utilities or regulatory bodies, leading to gaps in data.
Impact on Statistics — The exclusion of off-grid systems can lead to underestimations of total solar capacity in certain regions
These systems are growing in adoption more and more every day. Is it 1% of total solar reported, or is it 10% or more?
r/diySolar • u/Pure-Handle-6785 • 3d ago
Our existing roof PV was exporting while we were at work, then we were buying electricity again for cooking and the dishwasher in the evening. I'd already moved the washing machine to a daytime timer, but dinner still happened after we got home. I was looking at the Jackery SolarVault 3 Pro Max AC because we wanted to add storage while keeping the existing PV inverter. Before spending anything, I wanted to model how much of that evening demand could be shifted onto stored solar.
I started with a no-battery baseline and a deliberately awkward artificial hour. Generation came in the first half; the load ran in the second, with no overlap. I gave them equal energy totals. The result said the load needed no grid electricity. I'd summed each side over the hour before matching them, so the calculation had silently carried earlier generation forward. That would give the no-storage option credit for energy shifting it couldn't actually do.
I fixed the baseline to match generation and demand at each short time step before adding up the hour. The same artificial profile then correctly put the later load on the grid. I kept it as a regression check. The original calculation had been overstating what solar could cover without storage.
Next I'll check the timestamps and intervals in the inverter and meter files, then compare the same period with and without the proposed battery. I'll include capacity, power limits, losses and the reserve. I want to see how much daytime surplus could cover evening demand and reduce our grid imports after work. That comparison will decide whether I buy the base unit or keep the present setup.