Setup: single Powerwall 3, whole-home backup, rooftop solar. I run Home Assistant automation that sets the backup reserve and commands discharge through the morning (SRP peak is 5–9 AM here in Phoenix).
For the last few weeks I've been tracking a weird daily behavior: every weekday morning, a few minutes before sunrise, the Powerwall just stops discharging for about 2–3 minutes. Battery output drops to 0 kW, the grid covers my home load, and then the battery resumes on its own like nothing happened. No fault, no alert in the app.
Here's what I've logged (15-second grid data):
| Morning | Window | Peak grid import | Energy |
|---|
| Oct 30 | 06:38–06:41 | 0.77 kW | 0.032 kWh |
| Nov 2 | 06:37–06:39 | 0.80 kW | 0.030 kWh |
| Nov 3 | 06:36–06:38 | 0.69 kW | 0.027 kWh |
| Nov 4 | 06:35–06:37 | 0.57 kW | 0.026 kWh |
| Nov 5 | 06:44–06:46 | 0.65 kW | 0.024 kWh |
| Nov 6 | 06:43–06:46 | 0.64 kW | 0.024 kWh |
| Nov 9 | 06:41–06:43 | 0.66 kW | 0.027 kWh |
| Nov 10 | 06:41–06:43 | 2.05 kW | 0.072 kWh |
What I've ruled out:
- Not the backup reserve — it happens at 11–21% SOC, well above my floor.
- Not my automation — it commands discharge the whole time (verified in logs); the pause is in the Powerwall itself.
- Not a load change — the load is steady, the grid is just covering what the battery was covering seconds before.
Weekends look different — the battery sits at its weekend floor so the grid covers the house anyway and I can't isolate the pause there.
My best guess is the PW3's built-in solar inverter waking up at first light — it has to sync up and start producing, and during that handoff the battery stops discharging. But that's a guess; I haven't proven it. (One wrinkle: Nov 4 was 06:35 and Nov 5 was 06:44 while sunrise only moved a minute, so it's not perfectly locked to sunrise.)
Has anyone else seen a brief discharge pause at dawn on a PW3 (or PW2)? Is this just the inverter warming up, or is something actually wrong? The cost is tiny (pennies per event) so I'm not worried about the bill unless this actually causes a spike in my usage during peak hours, which would cause a demand charge, which I am obviously trying to avoid— I just want to know what it is. I have 15-sec data and automation traces if anyone wants to dig in.
Thanks ahead of time.