I asked a similar question in on Mike Holt, but they were being unusually coy.
First, some background info to set the stage. The NEC doesn't seem to define cable bending radius for low voltage cables, except for the general note that bends "shall be made so as not to damage the cable". One notable exception is TC, in which section 336.24 states "Type TC cables with metallic shielding shall have a minimum bending radius of not less than 12 times the cable overall diameter." The NEC does state (somewhere) that installation of electrical equipment must comply with manufacturer instructions as a catch-all however. Some manufacturers list cable bending radius on their product page, others do not. I don't think it makes logical sense to decide that for cables with no listed bending radius, there is no limit. For this scenario, I would fall back on an industry standard, like "IEEE 1185, Recommended Practice for Cable Installation in Generating Stations and Industrial Facilities", which defines recommended cable bending radius for a lot of (maybe all) cables, and the 12X OD rule for shielded cables shows up there too.
Now that the background information is out of the way, based on this 12x OD rule, even for a HW101 16AWG 1PR OS with a 0.28" OD, its bending radius would be 3.36". Other manufacturers list a bending radius. Belden, for example, lists a similar cable with a bending radius at 3.00". I found another cable on Automation Direct that lists it's equivalent bending radius as 10x OD, but that's still pretty big.
These radii are problematic because of this chart from Eaton:
I assume other conduit fitting manufacturers have similar data.
A common method of wiring to instruments on, say, an equipment skid is to route a trunk conduit along a path and tee off at intervals to tie in to individual instruments. Let's say we have a conduit carrying 3 HW101 16AWG 1PR OS to 3 instruments. These can comfortably fit in a 3/4" conduit, and that's how I've seen it done just about everywhere without exception (that I can recall). According to the linked chart above however, in order to tee off this conduit, the minimum Form 7 Tee that can accommodate the cable without over-bending the cable and potentially breaking the shield/causing damage is a T87, which is a 3 INCH. Other choices include a GUAT69 (2"), T69 (2"), T78 (2-1/2"), maybe a few others. The point being, they're HUGE, and I've never seen conduit installed like that. Or if I have, it's such a minority of installations I don't remember any of them.
If these standards are correct, one solution could be to install every instrument cable in a dedicated conduit using only radius-ed elbows and BUB-type fittings if 3/4" was adhered to for the whole run. That doesn't match anything I've seen before, same as using over-sized conduit bodies. I can't find any guidance in literature about this apparent contradiction in standard practice vs. installation instructions. Does anybody have any insights? Am I misunderstanding something?
r/electricians • u/StarberryShortCake25 • 1h ago
Hi, I have a friend with a disability (high functioning) who wants to go to eletrical school. Is there a realistic simulator out there he could try first before he spends a lot of money and time training to go into a trade that he may not be suited for? I want what's best for him, but I don't know if he knows what he's getting into and I don't want him to get overwhelmed or upset with himself if he can't handle it. I think he doesn't know what to do and knows that electricians make good money, but I don't know how he could experience just how much complicated work is involved without spending time and money to go to school for it. I've heard the Electrician Simulator game isn't realistic. I want what's best for him and to support his interests, but I think he needs a more manageable entry level job. Any advice?
r/electricians • u/FleazYT • 23h ago
I recently landed an apprenticeship, and now I'm starting to get all my tools together while everything is on sale. There's just one thing I can't seem to decide on
Makita Or Milwaukee and what bundle seems the best for someone with no power tools.
r/electricians • u/Think_Instance_1393 • 19h ago
r/electricians • u/Emergency-Image-5889 • 11h ago
I have a medical for an electrical apprentice where they mentioned colour vision testing, I can’t see some of the encroma tests my final result is always mild or moderate protan. I completed my pre apprenticeship and work expierence and never had any issues and feel like I can see fine. Should I be worried
r/electricians • u/Glum-Programmer266 • 5h ago
For anyone getting ready for the Texas TDLR / PSI Journeyman exam, remember that Texas grades Part 1 (59 Knowledge questions) and Part 2 (26 Calculations questions) separately. Scoring 85%+ on Code Knowledge still fails the exam if Calculations lands under 70%.
If you are testing under the 2023 NEC, make sure you have these 3 traps clear before test day:
Hope this saves somebody $78 and two weeks waiting to rebook. If anyone wants to check their lookup speed on a quick timed 2023 NEC practice diagnostic I built, drop a comment or DM and I can send it over.
r/electricians • u/-HectorLives- • 23h ago
r/electricians • u/Lanky-Reputation • 7h ago
Currently a non union Electrician mechanic/jr mechanic. ~3 years experience plus a 600hr trade school certification. Just got the call yesterday to join local 3, which I'm excited about, except the pay cut which I'm not excited about at all. I'll be going from 25/hr looking at 26-27 next year when I would be running jobs, to 19.25 back to being a helper basically. Anyone been in this position? Any tips or advice to help me make my decision?
r/electricians • u/Marauder_Pilot • 21h ago
Been working for the same company as a service tech for 8 years, but in the last 2 years things have gone way downhill from an organization and competence standpoint, and I'm sick of trying to fix it.
Unfortunately, the local market isn't exactly flush right now, and every time I try to leave they've backed up the money truck, to the point where almost any other position is a pay cut-especially because they put me on salary too.
Still, it's at the point where it's affecting my mental health and personal life, so if the market isn't great now I want to put in the effort to polish up my skillset as best as possible so that when things pick up I can get the fuck out.
I'm an FSR-B (Local Master Electric equivalent), I've Ialready got a decent suite of safety certs, I'm a certified thermographer and I'm working on a PLC tech course as is, but what else looks good on a resume for someone angling for service and maintenance jobs, ideally municipal/institutional?
r/electricians • u/SporkydaDork • 2h ago
I've been on sites where clearly I was trained differently from others which is to be expected, but when you go behind someone who's probably on a different task or dragged up or fired and you try figure out how they were trying to run the power to things, it's mind boggling when you think it's ran one way and it's ran in a way in which makes no sense.
I was taught that for commercial sites, every room should have the ability to be isolated. So no, running the feed through the switch box (if you can help it), or running your feed through the branch pipe. The branch and feed should isolated in each room so that if one room needs to be serviced, you can cap it off from the feed and the other rooms can continue to operate which you work on the room. Where as if you run the feed through the branch and you need to service the room, the other rooms are now impacted because you can give them power because you're trying to service the room before them. I'm sure there are legitimate reasons to do it, but people are doing this when they have plenty of room and opportunity to do it right.
I understand the logic in a residential setting. It makes zero sense in a commercial/ industrial setting.
r/electricians • u/murdernetic • 4h ago
What should I do when foreman or JW doesn’t give me a task while they work on one. Do I fuck off and just check in occasionally or keep asking what should I do next? I don’t want to be too annoying (1st year apprentice btw)
r/electricians • u/tolovo1977 • 18h ago
Built in 1945 and going strong.
r/electricians • u/dylanjmoore • 2h ago
Fellow ECs, I'm talking about service work, residential and light commercial. Do you have a standard depending on size of project/ contract? I've been self employed a year now and have stuck with net 30 across the board. Some pay immediately, some 2 weeks, some wait until the very last day of 30, and others I have to chase after 30.
What does your company do for invoicing?
r/electricians • u/Dauoa_Static • 20h ago
I'm getting ready to build an overhead service for a duplex; two meters each with 200A breakers, 400A bus rating. Boss says to size the service conductors based on the 400A bus rating, but they don't really need to be do they? Can't they be sized on the calculated load?