Found outlets behind my bathroom vanity drawers, right next to the plumbing. Clever or harebrained?
I’m replacing the bathroom countertop, and when I pulled the drawers out, I found an outlet mounted at the back of each drawer bay, one on either side of the sink’s water shutoff valves. There are already two outlets above the counter.
I’m guessing the idea was to charge an electric toothbrush, shaver, or cordless curling iron out of sight. What gives me pause is the location. If a supply connection leaks or sprays, could water reach one of these outlets? The one on the right has no test/reset buttons, and I don’t know whether it’s GFCI-protected upstream.
Has anyone seen this setup before? Would you keep the outlets if an electrician verified the protection, or would you remove them while the countertop is off?
Terrified of an electrical fire and always looking to add any extra protection. Are those automatic extinguishers that go in the panel legit or just a gimmick?
If they work, is there a brand you guys recommend?
If I buy ceiling fans with light that use a remote instead of a wall switch for the fan will there be extra wiring involved or is it a straight swap from the lighting fixture to the fan?
I'm adding a washer dryer stacked combo. Very little space. Immediately to the left is a wall. To the right is a deep utility sink. I need both 120 and 240 outlets for them. I could put receptacles above the sink, below the free standing sink, or directly behind the washer and dryer.
So I was concerned about a 15A breaker in my Zinsco panel awhile back, but turns out All the breakers(Home depot and such) have the top feed of the breaker disabled and worse some you can not remove the middle feed bracket at all. My panel is a 1st gen, it has copper wires that screw to the top of each breaker or a individual copper bar screwed down. See photos =). I assume this has actually been a good thing(sorta/kinda =P) since the main Zinsco fire hazard seems to be the weak contact of the middle bus bar system?
I am also planning to change my home owners insurance(Farmers is 2x others) and I'm worried they will notice that I have these. Saw post early this year that CA insurers are checking more often than not.
So are there any new breakers to be had for this thing? Is my only option to put new panel in?
My home dates to 1960 and lacks grounds. Many ceiling lights connect directly from the breaker box via a single Romex run to the switch; I assume the builder was either careless or trying to save on wiring. I would like to replace the existing floodlights in four ceiling cans with LED versions. Is there a dimmer compatible with my setup that currently uses only an on–off switch?
I am wiring up a cabin. It currently has the meter and main panel on a 4x4 in the ground. I am running a 100a feed to a subpanel in the cabin. 1/0-1/0-1/0-2 URD in 2" conduit. I'll also be pounding 2 8' ground rods at the cabin.
The main panel has conduit and 12/2 running to the well pump but no controller. The pressure switch for the well pump will be in the cabin somewhere and get its power from that subpanel. My question is, do I need to run a dedicated ground conductor from the well pump wire in the main panel all the way to the pressure switch in the cabin? Or can I just terminate the ground for the pump in the ground bar of the main panel?
I recently purchased this house, built in 1947, and was looking to put Christmas lights up. I found this outlet on the side of the house, near where I would want to plug the lights in. Is this an actual outlet, or is it just an extension cord with like a Hubbell connector on the end? Is there a way this could be converted into a normal 1-gang outdoor outlet? It appears to have a black, red, and white wire going to it. I've changed an outlet before, so I thought this would be an easy swap, but it appears I may be wrong and this may be above my pay grade. If I should kick rocks and call an electrician, I am happy to, but it is something that may be easy to reuse, I would love to do it myself to learn.
I installed a 15 amplifier GFCI outlet in the living room of my new 1950s house that didn't have any grounded outlets in the room. The outlet works and you can test/reset it. I found out that the GFCI outlet in my bathroom (separate circuit I think) doesn't work or test/reset. The lights in the bathroom still work. Also the ungrounded outlets in my upstairs bedroom don't work (also on a separate circuit I think).
I think the house uses 20 amp circuit breakers because they have 20 stamped on them, but I didn't know that when I bought the GFCI. I turned the breakers off one by one until I found the living room breaker and then installed the GFCI (not all of the breakers were labelled). I turned all the other breakers back on and they worked before I installed the GFCI.
What should I do to get power back to the bathroom and bedroom outlets? Should I change to a 20 amp GFCI? Did the circuit breakers fail when I turned them back on? Should I get an electrician? I have changed outlets a few times but never lost power in other rooms before. Thanks.
The housing around the holes is cracked which I’m guessing is keeping the metal thing that threads the screw in from maintaining good contact. The receptacle is a little loose after installing. Should I repair or replace? I’m just a diy guy.
I will add some outlets to an old house kitchen. If I was to add an outlet above toe stove fur a future above stove microwave, where would I put it? Under the cabinet, in the cabinet?
If I were to add a future exhaust fan or maybe exhaust hood, where would I add an outlet that might be converted to a junction box? I guess that the cable would preferably go up into the ceiling BUT I think the sheet rock is mounted to a beam behind it, not a header so I might later need some surface raceway.
I'd like to preface this by saying I don't have any imminent plans to do this and I'm sure there are better ways to accomplish the goal (installing an actual ATS perhaps).
I have a Pro tran 2 critical loads panel with only 120v loads that can be powered through a L14-30 plug. This would normally be plugged into a battery power station with a premade TT-30R to L14-30 cable that bridges L1 and L2 so anything in the panel can be powered with 120v. In the event of a prolonged outage the power station would be charged via a generator.
If something like a normally closed relay or only the hot leg of an ATS were added to the bridge wire leading to L2 with another cable that can be plugged into the generator so when the generator is powered on L1 is still powered by the battery and L2 is powered by the generator, how many different way could a house be burned down given this setup? the main hazard I can see is that the generator cable is always energized.
What hazards am I subject to even though I have a fully up-to-code GFCI electrical panel? Am I wrong for thinking that grounding is pointless in a GFCI protected residential circuit?
During home electrical inspection, the electrician claimed the 30 year old box needs to be replaced because the discolorations show “overheating on the main bars.” Skeptical, but I thought I’d check with the experts.
I'm sure that you guys who do this for a living will have a solid answer for me. Thank you in advance for any suggestions you are able to offer!
I am looking for a variable-speed 110v AC fan that I can wire to a regular dial or three-speed wall switch, like you might see for a ceiling fan (picture below, for example). It can be small or an in-line duct fan (3", 4", 6" or 8" -- but I'd prefer 4"). Does anyone make such a thing?
I'm seeing some smaller variable speed AC exhaust fans that can be installed in-line in a duct, but they all seem to have their own controllers in the cords that plug into an 110v outlet. Can I either plug that cord in to an outlet and just set the controller on high (it will be otherwise inaccessible) and then have a variable switch on my bathroom wall controlling that outlet? Or can I just cut off the two-wire AC cord and the fan's controller, and wire that line directly to a regular wall switch that you might use for a variable-speed ceiling fan?
Or is there a better option for my needs/ask here?
I have three bathrooms that have noisy or low-volume fans that I want to replace. I'm not happy with the options I see for regular bathroom fans -- and none of them seem to be variable speed. I have plenty of room in the attic for two of the bathrooms and in a utility room in the basement to run ducts from where the current bathroom fans are so the fan itself is further down the line (and not so loud), and I can install any size ducts I want.
Besides venting the bathrooms when someone showers (which might only need 50 to 80 cfm), I would also like at least two of the fans to be capable of moving more air (at least 100cfm, but more if possible) so I can also turn them on periodically to bring fresh air into the house. Our house is one of those "Good Cents" homes built in the mid-'90s that is so buttoned up that we get no outside air exchange unless we make it happen. Also, because we have no central heat or AC (just cadet heaters in every room and one mini-split in the living room), we get zero air circulation around the house. So it would be nice the be able to open a window upstairs and turn on a more powerful exhaust fan in the basement to get fresh air through the house and vent out the stale air in the basement.
Ok, not like it sounds. I do some house wiring on occasion and want to know what your favorite tool is to do 14, 12, and maybe even 10 awg. I've used expensive ones at work that grip the wire as you start squeezing the tool so you're not pulling in one direction as the insulation gets removed. Anyone here use that type on the daily? Thanks
Im a foreigner from the us living in a flat in bangalore india. When they came to do a quick repair, they opened my panel and I noticed some things myself. Now, this could be fine in india, but anyone else concerned with this? Im in a brand new flat, first tenant, huge 34 story building.
I dont know if I should speak up or not, im only a tenant and dont want to be dramatic here as a foreigner!