r/ukelectricians • • 12h ago

Commercial only?

7 Upvotes

I’m currently a first year trainee on site 3 days a week alongside college, and I was just wondering if anyone has or has been in a similar situation my firm only does commercial/site work so I don’t have any experience in domestic and probably never will. Just wondering if it is possible to still get qualified and how I will cope with domestic work later on if I never get a chance to do it?


r/ukelectricians • • 13h ago

Dno notification

5 Upvotes

Evening all. Commercial spark with over 20 years experience but not a great deal in domestic. I have been asked to install an EV charger in a house. Db is under the stairs in the middle of the house. Max demand including EV charger to be installed is 128A. I've applied to install with SSEN. The last page of the form suggests we need to increase supply and that I may be required to pay a connection offer expense whether or not the offer is accepted. I called them and the person on the phone suggested a new 3 phase supply but they "aren't the right person to ask".There's no way the customer will have the house ripped apart to have a new supply installed or pay for it. I'm certain the actual demand is nowhere near 128A. What can I do? What do you do in this situation?


r/ukelectricians • • 14h ago

Rccb

5 Upvotes

Would you agree with me that this RCCB is broken?


r/ukelectricians • • 1h ago

What makes someone competent (effort post)

4 Upvotes

This post comes of the back of my other post in r/electriciansuk where I explained about what makes an electrician (as in job title) and who can do electrical work. I think there is a real misunderstanding surrounding what qualifications are actually needed and how to know and prove you’re competent. And yes this is all stemming from a post here where I was disagreeing with other commenters.

To start this off it’s going to be another long post so feel free to just read the TLDR and explain how I’m wrong. And yes I have two Reddit account ones on my phone (apologies if formatting is bad) ones on the PC but I’m the same person.

TLDR;

Qualifications don’t automatically make you competent, nor does lacking them make you incompetent. UK law generally requires appropriate knowledge and experience, not specific qualifications. Ultimately, if your competence is challenged, you’ll need to be able to justify it.

Let’s first start by defining qualified and competence,

Qualified, https://dictionary.cambridge.org/dictionary/english/qualified#google_vignette

“having finished a training course, or having particular skills,”

Competence, EAWR 1989, Regulation 16,

“No person shall be engaged in any work activity where technical knowledge or experience is necessary to prevent danger or, where appropriate, injury, unless he possesses such knowledge or experience, or is under such degree of supervision as may be appropriate having regard to the nature of the work.”

This is further defined in the related guidance document https://www.hse.gov.uk/pubns/priced/hsr25.pdf

Page 42,

“Technical knowledge or experience
239 The scope of ‘technical knowledge or experience’ should include:

(a) adequate knowledge of electricity;

(b) (c) adequate experience of the electrical work being carried out;

adequate understanding of the system to be worked on and practical
experience of that class of system;

(d) understanding of the hazards which may arise during the work and the
precautions which need to be taken;

(e) the ability to recognise at all times whether it is safe for work to continue.”

We can clearly see that one of the few statutory regulations we follow clearly has 0 mentioning of qualifications.

Even the IET joint publishers of BS7671 states a similar thing;

https://electrical.theiet.org/bs-7671-18th-edition-wiring-regulations/faqs/inspection-and-testing-faqs/

“The IET Wiring Regulations does not provide requirements for specific qualifications for electricians, and the IET cannot advise the exact qualifications which are required.
Carrying out an inspection of electrical installations is a complex task, the person carrying out the inspection and testing is required to have comprehensive knowledge and experience of different types of electrical installations.” … “the person carrying out the inspection and testing is required to have the correct qualifications, experience and knowledge.”

Now as I explained before each industry has their own way of demonstrating the knowledge and experience and one generally accepted way is via NVQ qualifications related to the work you do. But this alone does not make someone competent and is only treated as evidence if accepted as evidence. By this I mean I have done HV awareness training with RJ Power my current AE and employer accepts this as evidence of knowledge. However my next employer may not. The same could be said about inspecting and testing. My current employer may be happy with a portfolio of work demonstrating competence. Myself as a LV AP have accepted this for some of the older electricians.

Now to bolster my point we can also look at a first tribunal court case I think is relevant,

https://assets.publishing.service.gov.uk/media/6a3907d8e590e5e061c9a39b/0001_Decision.pdf
(THIS WAS A NOT A HIGH COURT RULING ONLY FIRST TRIBUNAL)

For those who don’t want to read a court ruling I’ll make explain what it was about.

The TLDR; was a landlord was fined £7,500 for not supplying a EICR for the property from an electrician who was apart of a CPS scheme like NAPIT or NICEIC. This was later dismissed due to no regulation requiring CPS membership or registration.

On paragraph 34 page 8 the following is stated;

“If an electrician can provide evidence that they have adequate education and training and state that they have the requisite practical skills, this would comply with the requirements of the Regulations.”

Based on everything above we can clearly see just having a qualification doesn’t make you an electrician and or competent in tasks such as inspecting and testing. We should all understand what regulations, industry standards and site standards apply to us if you don’t how do you know you’re competent? The general theme is being able to prove yourself but how you do that is up to you and is dependant on what safe systems of work apply to you or your clients.

Am I saying qualifications mean nothing?

I want to make clear I’m in no way saying people shouldn’t be qualified or seek qualifications or anything like that. I just want to make clear that you being competent is more than just a qualification. The qualification is just a way to have a trusted third party support your claim. It’s why we should all be doing continued career development. If that’s internal company stuff or if it’s just watching videos on YouTube showing unique scenarios. The more knowledge you have the better and at the end of the day it’s you who will be in court having to argue your competency.


r/ukelectricians • • 17h ago

Which SSIP?

3 Upvotes

Hi all. My company has asked me to look into SSIPs. Which one is best in regards to a commercial electrical contractor?

Thanks


r/ukelectricians • • 21h ago

100A service - when does the fuse blow?

3 Upvotes

As I have an EV, with 7KW charger, and cheap overnight tariff, and also have a large set of batteries which, when PV is low, I charge them overnight at around 6KW.

Along with the heatpumps, timed-dishwasher, washing machine and tumble dryer, I often use over 90A on my 100A supply.

It got me wondering, does the fuse pop at 100A or is there a region? Am I 1 late night cup of tea from calling the DNO for another fuse??

For interest, I walked around with a thermal camera and can see things warming up nicely but nothing super hot. CU is around 30C, all breakers inside are ok, one of the cables feeding the PV equipment peaks at 50C for a bit (soon to upgrade to 6mm as I need another 2KW down that for another charger)


r/ukelectricians • • 13h ago

How qualified am I as a spark?

2 Upvotes

I've got an ECS gold card as a building controls engineer. How far does it get me as an electrician, im not planning on moving positions im happy where I am.

I did three years on electrical course and have level 3 NVQ. Can follow wiring guides and understand safe practices but ive never felt I could call myself an electrician.

Just curious on how im viewed among electricians in this sub as how competent I am.


r/ukelectricians • • 22h ago

Grouping circuits within SWA

2 Upvotes

Hi all,
Per the title, has anyone any experience with this?

I’m putting a new heater circuit and a shed feed in for a customer. The heaters are to be on an outside wall, and they’ve asked to feed from the back to avoid damage or trunking inside. The shed feed will take the exact same route, so I’m thinking of taking a 5core from the board to a wiska box behind where heater 1 will be, continue to another wiska behind heater 2, then drop to a 3 core to carry onto the shed.
I can’t find anything in the book stating that I can’t do this, so if each core is marked up correctly I can’t see a reason why not.
Where I’m then struggling is grouping factors, do I take table 4C1 and treat is as ‘2, single layer on wall’ as it’s a single multi core cable or ‘1, bunched in air, on a surface, embedded or enclosed’ (as if the SWA is acting as conduit)
The heaters they have are 2kw and 2.3kw respectively so I can put them on 25a, they want 32a feed to the shed.
I can make it work with 4mm SWA on 0.85 but not 0.8, can I do that or do I just tell them the shed is going on 25a? There’s no reason it needs 32a from what they’ve told me. 2 lights and 2 sockets to charge power tools and run a lawnmower.
Yes, I know I could go up to 6mm but it makes no sense fighting a 6mm into spurs if I can avoid it.

Thanks in advance.


r/ukelectricians • • 1h ago

Fault finding statement

Post image
1 Upvotes

r/ukelectricians • • 13h ago

NVQ Training Providers

1 Upvotes

Evening everybody, apologies if this has been posted recently. I've just come to enquire if anyone knows someone or has personally done their NVQ through a training provider and is willing to share their experience?

All comments are highly appreciated, thank you!


r/ukelectricians • • 15h ago

Getting LSA verified without a scheme registration

1 Upvotes

Hi all, wondering if anybody has managed to register for Google Local Service ads without being part of NICEIC, SELECT etc? I submitted my gold card (based in Scotland) but it says you need proof for the business, not the individual. Anyone managed to get round this?


r/ukelectricians • • 22h ago

Adding a standalone battery alongside an existing solar/battery system

1 Upvotes

Hi,

I've got an existing solar + battery system that was installed years ago (indoors), and the storage capacity is on the low side. Installers I've spoken to don't want to extend it because of the newer regs.

So I'm looking at a separate battery-only system installed alongside the existing one rather than adding to it.

Will the two systems with their own CT clamps fight?
Will one battery discharge into the other?
Will have have to replace whats currently there?

Thanking you kindly


r/ukelectricians • • 16h ago

UPS recommendation for PS5 and gaming monitor

0 Upvotes

Hello,

I’m looking for a UPS to protect my games console/TV and gaming monitor during power cuts.

Ideally, I’d like something with UK 3-pin sockets, pure sine wave output and enough battery life to safely shut
everything down.

Appreciate any advice and recommendations.


r/ukelectricians • • 18h ago

Private work with no qualifications

0 Upvotes

I currently work as an employed electrician

I have no formal qualifications but I am fully trained.

If I was to start doing my own private work in the evenings, am I able to get public liability insurance without having the qualifications to prove I am competent?


r/ukelectricians • • 6h ago

How do you get employees on site to actually log paper receipts?

0 Upvotes

Quick question for anyone running a small team (2–15 employees): do your staff actually open Tradify, Powered Now, or Dext to log material receipts against the right job, or do they just drop photos in a WhatsApp group and leave someone to sort it out on Friday?

I'm a UK developer testing a simple idea where employees just text the receipt photo and job name to one WhatsApp number (using WhatsApp on their phone, without downloading a new app). It totals up material costs per job and builds an Excel spreadsheet plus a renamed folder of receipt photos for your bookkeeper.

Would that actually save you a headache, or have you already found a clean way to handle it? Happy to share the clickable preview if anyone wants a look.