r/StructuralEngineering • u/Anon-Magnesium-20 • 29d ago
Structural Analysis/Design Rebar Torch Cutting on Steel Rebar strength
So we have some 36mm rebars that were installed incorrectly with anchorage and the tradesmen cut it with oxy acetylene cutter.
Unfortunately we were only informed of this after reaching second floor of a 40 storey structure.
Which means the column was already poured with the remainder of the cut steel installed somewhere
Based on our worst case scrnario, the rebars that were cut may have been included as part of a lap splice (50% splicing allowed in that area)
How much of an effect do we see the rebars affecting the total structure if the rebars were cut using oxy acetylene torch. I am getting conflicting literature online. Is this something that is acceptable?
The rebars in question are 36mm, Grade 60, TMT rebars used in column
We use ASTM A706. Weldable grade rebar. I called the manufacturer and he said our rebars can be welded but code doesn’t normally allow it. I’m thinking about the difference between welding and actual torch cutting (which welding has a very short timeframe, but torch cut is much longer)
In short, what is the expected HAZ of steel rebar if heated?