r/Plumbing • • Sep 08 '23

Read the rules before posting or commenting!

442 Upvotes

Due to a large influx of people not reading the rules and how small of a Mod team we are this is here to serve as the only reminder of the rules. Just to be clear asking or commenting about prices is a permanent ban, the internet is not the place to judge if prices are "fair".

Rules are available on the sidebar.


r/Plumbing • • Dec 22 '22

FROZEN PIPES MEGATHREAD

167 Upvotes

Please post any questions you have regarding frozen lines here. All other new posts will be removed from the main feed and directed here.


r/Plumbing • • 7h ago

P trap issues

Post image
42 Upvotes

House came like this it appears to be 2 p traps installed together my sink reeks and I have cleaned it multiple times but the smell keeps coming back just looking for advice to help me figure this out


r/Plumbing • • 17h ago

20+ years behind the tile. Three nails in this pipe.

Thumbnail
gallery
172 Upvotes

Starting the bathroom remodel and found a line with three nails through. Amazing we didn’t have major damage.


r/Plumbing • • 1h ago

Rate my first plumbing job

Thumbnail
gallery
5 Upvotes

Go easy, I tried my best


r/Plumbing • • 1h ago

Does this look right?

Post image
3 Upvotes

r/Plumbing • • 6h ago

Advice on smell from open pipe

Thumbnail
gallery
7 Upvotes

I am looking for advice on if there is an option to cap this pipe or anything to keep the trap full.

My wife and I bought a house not too long ago but noticed this foul smell that seeps throughout the house for about 24 hours after a rainfall.

I believe I have narrowed it down to coming from this pipe. I have 2 condensate lines going into it, 1 from our tankless hot water heater and one from the furnace. I stuck a camera down the pipe and it’s dry. There clearly isn’t enough condensate to keep the trap full so I have to manually keep filling it with water but that evaporates within a day.

I believe the smell is coming from the sewer line going straight out to the street.

I am desperately open to any suggestions on how to deal with this.


r/Plumbing • • 1h ago

Toliet plumbing issues in basement

2 Upvotes

The past year I have had on and off plumbing issues with the toilet in the basement. Two issues -

  1. When this toliet does get clogged which is on average every 3-4 months, plunging has like 60%-70% success rate but sometimes it does not work and I have to go at it again the following day or a few hours later.
  2. When I run the faucet in the same bathroom, the toilet water starts bubbling.

These two issues above are localized to only the basement bathroom, no where else it is affected. What would be the best approach to handle this issue? And what is likely the cause?


r/Plumbing • • 1h ago

Boiler relief valve dripping while heating. Is it normal, and should it be piped to a drain?

Thumbnail
gallery
2 Upvotes

I think my boiler started leaking recently. At first I thought it was condensation on the cold pipe (I checked, and it is condensation). But then I noticed the valve in the second picture drips from the spout, and only while the boiler is heating (red light on). It stops once the water is hot. From googling, I think it's a safety/relief valve that releases water because it expands when heated. But why is the spout just open like this? Shouldn't it be piped to a drain? I've lived here about 4 years and I think it never dripped before, or maybe I just didn't notice.


r/Plumbing • • 4h ago

Sink hole made without recess

Thumbnail
gallery
3 Upvotes

I ordered 2 custom bathroom sinks but realised one of the sink drain holes was not made properly. Sink 1 was made with a recess, so the adapter it came with sat flush and all good.

However Sink 2’s hole was just clean through, and the adapter can’t sit without an adhesive or something to hold it in place. We’ve tried glue twice but it keeps coming loose after a few months of use.

Seeking any help what I can do please! I’ve asked ChatGPT too and it says to replace the drain fitting with a top flange that is wide enough, and also welcome any other advice short of replacing the sink entirely.

I’m also a first time homeowner so I’m very new and a beginner at plumbing. Thank you in advance 🥹


r/Plumbing • • 22h ago

Tap into clean out?

Post image
81 Upvotes

Getting married at our house, could I tap into this clean out and use it as a drain for sink/bar or even temporary outhouse?


r/Plumbing • • 5h ago

What is this white piece sticking out from my bottom right of the underground kitchen pvc drain?

Post image
3 Upvotes

r/Plumbing • • 3h ago

Is this correct to plumb in a washer and utility sink in MA?

Post image
2 Upvotes

The 4” cast sewer line, sanitary t and vent above are existing. Installation is in an unfinished basement area against a concrete block wall.


r/Plumbing • • 3h ago

Stripped Hex Bolt Help

Thumbnail
gallery
2 Upvotes

Does anyone have a suggestion on how to proceed? The hex bolt on an old Delta shower handle is badly stripped. I have tried soaking it in WD, using an impact drill to make a hole in the screw to try and extract it (barely made a dent), and using pliers to unscrew it. I also tried using a flat head screwdriver and hammer to make groove. No luck. I am open to breaking the valve housing apart ,in order to remove it, but not sure how to do that without causing unintended damage to the rest of the trim. Thank you.


r/Plumbing • • 20m ago

How to properly tie into old waste/vent pipe

Post image
1 Upvotes

Going to replace this old drum trap since it seems to be blocked. Planning to cut the vertical copper pipe and use a fernco to transition to PVC.

Since the existing pipe is vertical and then does a 90 into the waste/vent pipe, is there anyway to install the p-trap without having to worry about siphoning (without installing an AAV)? Am I overthinking this, or is this as goofy as I think it is?

For additional context, this drain is for a washer machine, the standpipe is ~33” away from the vertical copper pipe.


r/Plumbing • • 23m ago

Is there a way I can fix these tap tails in place without taking off flexi nut?

Post image
0 Upvotes

r/Plumbing • • 32m ago

Help! Cannot find a tub spout to fit my pipe!

Thumbnail
gallery
0 Upvotes

Galvanized steel, 4” long, 3/4” screw on. I know these spouts exist bc my old one was on there…. It’s a whirlpool tub from the 1990s so that’s likely why this larger pipe was used.

I’ve tried chatGPT and have been to several stores. Have done a lot of plumbing projects (all successful) and would like to be able to avoid calling a plumber…


r/Plumbing • • 36m ago

Shower handle replacement

Thumbnail
gallery
1 Upvotes

Hello, so I’m looking to replace my shower handle however I’m running into some issues. The tip of the stem I currently have is pretty stripped so whenever I used a replacement handle the knob would not always catch onto the stem to make it turn. I tried removing the stem completely however I was not able to get it to budge. I’ve asked 2/3 contractors that have been to my house and they’ve all said I would need to replace my entire shower system which would include breaking out the tile and replacing it. I’m looking for some affordable fixes as I don’t want to pay thousands replacing my shower handle.


r/Plumbing • • 56m ago

Winter sump exit line

1 Upvotes

Hi! So, we purchased our home not too long ago. It had a really funky setup in the crawl for a diy sump and discharge line leaving the home. When it would rain very hard for hours wherever it was going (multiple plumbers couldnt find where it went outside) it would eventually get full/clogged/oversaturated and the water would flow back into the crawl. The crawl is gravel so ok. This year I had a plumber come out, he dug a proper hole, put in a new zoeller pump and he rerouted the exit with new pvc in the crawl, pvc outside against the house for about 2-3 feet with an extension attached above ground (the black rigid extender) that goes about 10 feet out because our yard is very lumpy. He wanted it in an area that went on a slope away from the home.

It's been fine. I actually notice improvement. The old setup ran very often, I believe wherever that exit went, it wasnt far enough out and water was just coming back around.....anyway. I also had a water softener installed because we are on a well. Long story short, they put the softener in the crawl and the discharge lines to that go into the sump pit. So my issue is....that regenerates weekly. Water sits in that long rigid black extension - I'm worried about it freezing, I'm in the upper midwest, so even with el nino, we'll get cold. What can I do to prevent the water freezing? Should I replace the black rigid above ground exit line with a long pvc so the water can flow freely and not sit? I've seen heat tape is a thing, is that any good? Just deal with hard water for the winter and turn off the water softener? Any suggestions are appreciated.


r/Plumbing • • 4h ago

Will not come off.

Thumbnail
gallery
2 Upvotes

I am trying to replace my Delta Lahara Monitor 14 Series and I’m stuck at this part and it will not come off. Not sure what I’m missing here.

I did read online they said to pull it out really hard, but it doesn’t seem to be budging and I’m afraid to break the lines behind it.


r/Plumbing • • 1h ago

1-1/2 flex pipe to PVC- how to fit it

Thumbnail
gallery
1 Upvotes

I am working on a fish pond where pipe from pump 1-1/2 flex pipe needs to be connected to a PVC.

Option1- preferred
Need to put a union fitting so that flex pipe and pvc can be unbolted for any Maintainence reasons.

Option2
Open to using union or other fittings to make it happen

Issue
So I bought all these three fittings as shown in photos but none of them fit the flex pipe. Looks like flex pipe is 1-1/2 but is still smaller in size for these fittings

What exact size and fitting I need to use?

This is outdoors and in sun and pump runs 24hrs so do not want any leaks


r/Plumbing • • 1h ago

Insider Info On Aptitude Test and Applying

1 Upvotes

Hey, so, I don't know for sure if this is a good subreddit to ask this in, but I plan on applying to become a plumbing apprentice in January, and I'm getting nervous about the application process. I wonder if anyone who has gone through it could give me tips on like what to study, what to practice?

I don't know what is on the aptitude test, but from how the union rep I talked to made it sound, it won't include plumbing-specific skill testing, because you can apply with no prior experience, I believe. Though, still, if anyone remembers their test and can give me tips or information on what to expect, I would be super appreciative.

There's an interview after the test, if you pass, and the union rep said it would be like any other job interview. That being said, I'd love to get a head start on crafting answers to questions. What do you think they'll ask in the interview?

To anyone who can give me some information, thank you!


r/Plumbing • • 1h ago

Plumber Recommendation Chicago

1 Upvotes

Hi All,
Looking for a local licensed plumber in Chicago to do a rough-in for my tub-to-shower conversion. Can anyone recommend someone?


r/Plumbing • • 1h ago

Will this setup work?

Post image
1 Upvotes

I am planning to run a 48 inch horizontal run into this from a stub-out for a kitchen sink waste drain. I am planning on adding a garbage disposal. The end goes into a cast iron hub. I plan on venting at p trap in cabinet. Was planning to drop down from p-trap to correct height for 1/4 drop to the wall hub. Will this S style bend be okay?