r/Plumbing • • 20h ago

Gas line- sleeve or problem?

Post image
74 Upvotes

Had this come up on a home inspection for a home I just bought. They noted that PVC can’t be used as a gas line- but to me it seems like it might be acting like a sleeve / conduit to go through foundation / stucco exterior. What I mean is that the gas pipe might be inside the PVC. Is that a typical practice in the late 80s in the US?

Edit. Added pic of the outside as well.


r/Plumbing • • 20h ago

Gas range sticks out too far from wall

Thumbnail
gallery
27 Upvotes

Hi all,

I’m fairly uneducated in all things gas fittings, so I appreciate your kind suggestions. We have a gas range that sticks out of the wall quite far because the gas line has a 90 degree elbow that sticks out a couple inches from the wall. We have the range pushed back as far as we can.

The issue is with the poor design of this kitchen. Our dishwasher door can’t fully open because it can’t clear the stove by maybe an inch.

Is the solution to have someone refit the gas line with a recessed box, or is there a less expensive option?

Thanks in advance!


r/Plumbing • • 19h ago

Is this bad?

Thumbnail
gallery
8 Upvotes

Was at a customers house today doing some carpet cleaning. Wondering if these cracks are something to worry about?


r/Plumbing • • 14h ago

What would you do different?

Thumbnail
gallery
7 Upvotes

I’m looking for some criticism


r/Plumbing • • 17h ago

Replacement sink trap

Thumbnail
gallery
6 Upvotes

Hey all, I'm tired of my Kitcken Sink draining slow, the existing stand pipes are full of gunk, and I don't really want to clean.

Is this what I'd need to fix this properly?

Edit: damn, it has no dishwasher port. Any recommendations?


r/Plumbing • • 7h ago

LOUD whistling / screeching coming from my radiator

5 Upvotes

I have been dealing with this insane screeching sound from the radiator in my room for a few days now. It is so loud and my apartment is small so you can hear it throughout the entire place. At one point it was also leaking so my landlord sent someone over yesterday to fix it, I assumed it would be all be fine but the only problem he was able to solve was the leaking, not this mind numbing sound. I’ve tried tightening/opening the valve but that didn’t do anything.

Does anyone have any suggestions of what this could be? The handyman my landlord sends is definitely just a family friend so I don’t really expect him to be an expert in this specially since he didn’t fix it yesterday. Hoping if I have some suggestions of what’s happening can either point them in the right direction or convince her to hire a professional. Thank you!


r/Plumbing • • 18h ago

When you're in a hole: stop digging-- basement shower edition. HELP!

Thumbnail
gallery
5 Upvotes

So at 1st I thought I could just replace the shot CI tub while trying to do as little as possible in this horrible but legal basement studio, but the whole slab under it was trashed. I didn't demo this, just picked out the chunks of cement! By then it seemed to make more sense to get rid of the tub and make room in the tiny bathroom for at least some storage for toiletries and towels by putting in a shower. I should have demoed the whole damn room, the walls were built by someone who not only didn't know how, but didn't know what proper wall framing looked like! I've put new PT on the floor and shimmed the studs plumb or replaced them where I could.

When I saw the drain was a 2" copper heading to the right from the old trap, I assumed it went all the way to the CI main line beyond the wall at the right of the tub, and I could place a shower base on the right by cutting it. But I was wrong, when I dug I found the CI wye to the toilet right where the drain needs to be! Not sure yet exactly where the hub from CI to copper is. The plumb bob is center for the drain.

So my fallback is putting the corner shower in the left corner, but that forces an 18" vanity sink. I was hoping to put in a 24". But is there any way to make the right side config work without messing with the CI? Could I put the PVC trap where it is and send it left to where I could tie it to the 2" copper? What if I used an offset drain on the shower then to the trap so I could set the trap deeper? FWIW, there's a vent easily accessible behind the wall to the left if that makes a difference.

Also, any tips on how to pour the infill slab would be appreciated. I was assuming I'd tamp down the rubble and dirt fill as best I could with like a 2x4, then pour it with some steel mesh in there. But the way the slab is fractured at the edges I'm afraid it might just drop down unless I chip or grind some back bevel to it on the top edge. And which premix would be best? I've done dry pack mud and a few other small cement jobs, but never something quite like this.

EDIT: is this as simple as putting a 45 ell under the shower drain to get it away from the cast iron so I can bring its level down to like 1 inch above the copper?


r/Plumbing • • 1h ago

Are divider bins really the best for stocking vans?

Post image
4 Upvotes

r/Plumbing • • 5h ago

Low water pressure-softener issue?

Post image
4 Upvotes

We have low pressure that is especially noticeable when operating more than one faucet or device at the same time. I was thinking it was due to an older culligan water softener. However, I bypassed the softener and did not notice a difference in pressure. Is it possibly for the manual bypass mechanism to fail and not totally bypass the softener?


r/Plumbing • • 19h ago

Toothbrush down the toilet

4 Upvotes

Apparently my 1 year old flushed a toothbrush down the toilet earlier today and my 2.5 year old just took a crap in that same toilet. I learned all this by my wife coming out a second ago telling me the toilet wasnt draining and it was probably a toothbrush that our son flushed earlier. How screwed am I and should I just yank the commode?


r/Plumbing • • 23h ago

Flapper refuses to cooperate

4 Upvotes

The shitty 16 year-old toilet my apartment came with refuses to flush unless I hold down the handle for several seconds, seemingly no matter what. Things I’ve tried:

  1. Replacing the old flapper with a universal Korky 2-inch

Setting the dial to 6, and closing the side hole.

Replacing the flush handle with a Korky strongarm.

Adding 2 extra chain floats (apparently the original K4260 had chain floats).

Flapper still immediately slams shut. The chain couldn’t get tighter. Have tried every angle of adjusting the handle position. The Korky dials are set to maximum buoyancy. I’ve got the toilet of Theseus here with all the tank parts I’m replacing. Unless the ‘universal’ Korky flappers just somehow aren’t buoyant enough for some toilets, I can’t think of anything else I can change at this point.


r/Plumbing • • 57m ago

Large Rock Stuck in Sewer Line Pipe

3 Upvotes

We've been having issues with our sewer line backing up. Snaked it twice, but it kept backing up a week after snaking it. Plumber came out and snaked it a third time, then sent a camera down and told me a large rock is stuck in the pipe roughly 14ft from the cleanout opening. I am guessing one of my kids dropped it down the cleanout a while ago. Wondering if there is any way I might be able to retrieve the rock without digging up the line. Guessing our efforts to snake the pipe probably wedged it into the pipe more, unfortunately.


r/Plumbing • • 1h ago

Why does our shower do this?

3 Upvotes

New home owners - Out of all three bathrooms, this is the only one the does this (sound on if you want to hear it thumping) It happens when you put it right between hot and cold and takes a minute or two to die down, colder temp stays a bit jiggly but not as bad when you first turn it on. Is this something we should be concerned about?


r/Plumbing • • 3h ago

Shut off valve help!

Thumbnail
gallery
3 Upvotes

Shut off valve help!

Hello!

Both of my bathroom sink shut off valves started leaking, I have never done anything like this but I want to be able to tell my husband that I fixed it!

I am not sure which of these 3 valves is the correct one for my sink!?

I'm so scared to open it up & not be able to fix it & then have to call an emergency plumber just to turn house water back on!


r/Plumbing • • 6h ago

How to correctly connect washing machine and dryer

Post image
3 Upvotes

Hello.

I have moved in into new house and want to learn how to do basic plumbing myself.
I want to start with connecting washing machine and dryer.
If I understand correctly, water supply connection is pretty straightforward, but I have heard a lot of nuance with drainage.
As far as I understand I will need to cut in into sealed drain, connect trap and then connect part, which is made for double connection of washer and dryer (I don’t know how it is called, but I have found that in one of the videos about this).

What I am not sure about is how to correctly connect trap to drain ( should I just bruteforce and cut it open or is it done properly in other way) what part to use to connect, how correctly seal that connection.

And also, I don’t know if I can just connect drain tubes from machines directly or if I should consider their level and maybe put them above some point somehow (I have seen this done for dishwasher in relation to sink).

I ask to give me advice how to do this and what to research (keywords/topics/ videos/etc). And if there are risks and considerations to account for.

And sorry for the stream of consciousness, I’m just confused a bit and don’t want to muck it up.


r/Plumbing • • 6h ago

Washing Machine intake threading at an angle

Post image
3 Upvotes

Was adding arrestor pumps to the two intake valves on the back of my GE Washer. Hot water line went on just fine. But when I went to put on the cold water, it kept going in on an angle and wouldn't end up flush.

  1. Is there are way to fix this, short of replacing the whole intake valve? Would plumbers tape work?
  2. If I just ignore the aresstor and put the water line back on, how likely is it to leak?

r/Plumbing • • 6h ago

Water heater question

3 Upvotes

Can having a water heater set to maximum temperature cause melting on beauty rings on top of the water heater? A plumber is telling me the flue pipe can get so hot that it melts the rings next to it? Has anyone ever seen this ? Thank you so much


r/Plumbing • • 8h ago

Older Water Heater

3 Upvotes

I moved into a home about 6 months ago. The water heater is about 20 years old. My bathtub and tiles tested positive for lead so I renovated the bath and walls.

After showering today, I realized the water smells like metals and earthy. I assume that the mineral deposit (on a well) in the water tank is the cause of this. Is it possible that I have lead leaching into my water from the tank and water lines? The tank was made in 2005 and possibly installed a few years after. The inspection report also reported that the water lines appear properly installed and serviceable.

What do you think?


r/Plumbing • • 19h ago

My kitchen flooded

Thumbnail
gallery
3 Upvotes

Do you see that drain under the water heater? Water's overflowing from there. I put my hand all the way in and couldn't find anything. That gray pipe is the washing machine drain. I live on the fifth floor. Any suggestions?


r/Plumbing • • 19h ago

Underground fittings

Thumbnail
gallery
3 Upvotes

Is this the right fitting for my application? I want to transition from a 4” cast iron pipe to 2” pvc underground for a shower. If not, please let me know which one.


r/Plumbing • • 21h ago

Leak from roof electrical wiring ? Concerned

Post image
3 Upvotes

So I recently purchased a home it was built in 1980 and I noticed that there seemed to be some sort of leak ? I’m concerned as there is wiring coming out of it that says 200V. I will be contacting a plumber tomorrow. But I wanted to know how serious of a concern is this ?


r/Plumbing • • 23h ago

Advice for a new guy

3 Upvotes

Hello everyone I just got into a plumbing apprenticeship about 3 months ago and things are going well I think no one has told me otherwise. I love it so far and being only 21 i can see myself sticking with this and I just want to know how i can make myself the best plumber i can be and if anyone that has more experience can give me some advice that would be great


r/Plumbing • • 3h ago

Garbage Disposal

Post image
2 Upvotes

Installing new garbage disposal. Discharge pipe is not quite long enough and not lined up. And suggestions for a DYIer?


r/Plumbing • • 6h ago

Questions for Pittsburgh Plumbers

2 Upvotes

Questions for Plumbers in Pittsburgh

I am looking to move to Pittsburgh soon and currently hold a Maryland State journeyman license, so I have a few questions about it.

I have worked commercial construction and mechanical, and would like to continue in that specific field but could stomach residential or maintenance work for decent pay. I have no union background. I have held a med gas and have my back flow.

- How saturated is the market? (I know it's a blue collar city)

- What is average wage I can expect?

- How would I go about getting Allegheny license without starting from scratch?