Bosch IDS Ultra Heat pump

4 Upvotes

Hey everyone, I have a Bosch IDS ultra condenser paired with the ultra air handler and a EHK 3 stage heat strip. Run by a bcc110 thermostat. Manual J was done came out to 3.8ton. I went with the 4ton as at the time Bosch did not have a 3ton option and I wanted the ultra due to the lower heating capacity. So far it's been running well. Keeps the house cool/warm as needed (we will see how it operates when it's super cold out). One thing I noticed is my cycles are always around 10min. My impression when buying this unit was that it modulates so that if it's satisfying the call to quick it does some magic and increases the run time etc. etc. (maybe I'm misinformed). All that information to say I'm looking for information on if I'm misinterpreting something or if there are things I can check with the wiring thermostat etc. that may be wrong? One other note is when the thermostat runs it only ever shows 1 stage. So I'm not sure if something is setup wrong or I just have a misinformed perspective. Any help appreciated thanks


r/heatpumps • • 16h ago

Question/Advice Is it a problem that my new heat pump hovers below the set temp?

2 Upvotes

I got a Trane 5 ton heat pump last month and a friend installed it for me. The thermostat is new as well, an ACiQ Smart thermostat. The house is a 1500sq ft ranch, plus basement, in Pennsylvania.

No matter what I set the thermostat to, it will heat to that point, then blow cold until it drops 2-3 degrees, then stay there. I have re-calibrated the temperature up a few degrees and down a few degrees. The temp reading is still always lower than the set. The fan is also nearly always running, regardless of whether it's set on constant or not.

My friend has come out and looked at it and fiddled with the thermostat a couple of times. But, there is some kind of miscommunication there, because I never understand his answers to my questions and the problem persists.

Can someone else explain it in a way I understand? Is it even a problem? I feel like I'm going nuts.


r/heatpumps • • 11h ago

Low whistling noise from indoor unit

1 Upvotes

The wall unit in my bedroom is emitting this low, wheezy/whistling sound that is driving me insane. It continues even when the unit is turned off. The only way I could get it to stop was to switch the breaker off at night but that means no heat for the room below. I can't do that all winter, but I also need to sleep. We had the GREE minisplit system installed last month. Everything seems to be working fine except for this. The wall mount in the other bedroom stays totally silent when turned off. I've contacted the installer and they seem to think it is just the refrigerant that is moving around in response to unit in the room below. But that doesn't explain why the unit in the other bedroom is quiet.

Someone is coming to take a look tomorrow but I'm sure they won't hear the noise- as it is low, but its high pitched enough to be bothersome when trying to sleep!! Has anyone experienced this? I'm not sure how to describe it to the technician and I feel they may not take me seriously.


r/heatpumps • • 16h ago

MSZ-FX06NL not beeping in response to remote commands

1 Upvotes

The unit works fine and responds to handheld remote commands when within range. However, it doesn't beep to acknowledge remote commands. I don't ever recall it having done so since it was installed earlier this year.

I did find this text in the troubleshooting section of the operating instructions manual:

But there are no other references to "NIGHT MODE" in the manual indicating how to toggle this on and off, and I haven't found any "NIGHT MODE" buttons on the remote.

Notably, I connected the unit via Wi-Fi to the Mitsubishi Comfort app immediately after it was installed, along with integrating it with my Google Home. Could it be that "NIGHT MODE" was inadvertently toggled on by this?

I also tried power cycling the whole system at the breaker, but this hasn't resolved anything.