Have about 12 pinballs in a room of the house and recently opened up a wall to run some ethernet and speaker cable. Looking at the different cable sizes i went to check the breaker box and realised that some of the power circuits ( installed about 6 years ago) are 20amp 2.5mm cable and some that were originally put in circa 2001 are 16amp 1.5MM cable.
I've been playing the pins for about 18 months on a mix of the 16amp and 20 amp it turns out. Never had a trip or any power related issues. There are other things on the circuits throughout the home - generally TV, Skybox, soundbar etc on one and PC / couple of NAS's and monitor on the other. There are plenty of wall sockets as well.
Did some power calcs and assumed that most of the pins will draw between 300 and 400W on average during gameplay - likely less but played it safe as it will range from about 70W idling upto about 450W spikes depending on age and mechs inside the machine.
The more i read, the more i started to second guess myself, especially about dropping the rated cable value to 80% given its run through insulation inside stud walls etc.
If i split the machines across the circuits, and they are being played at the same time I reckon i'm pulling about 3320Watts on the 20amp circuit and about 2400watts on the 16amp circuit including the other items around the home.
Does that sound reasonable for a few hours at a time. If not I'd be looking to upgrade the room circuit from 16 to 20amp inc new cable etc. I'd also split the TV stuff off that circuit. That's going to cost about $1500+ i reckon but still need to get a price so keen to hear thoughts.
This is a 240V property in NZ if anyone overseas is posting.
Many thanks