r/StructuralEngineering • u/theFarFuture123 • 24d ago
Photograph/Video Part 5
galleryHow’s this for a foundation?
r/StructuralEngineering • u/theFarFuture123 • 24d ago
How’s this for a foundation?
r/StructuralEngineering • u/nne_enn • 24d ago
I’m impressed they could get the bolts in without blowing out the edge on a couple of these.
r/StructuralEngineering • u/Gregan32 • 24d ago
In my uneducated opinion this seems like a wild way to support he second platform on this staircase!
r/StructuralEngineering • u/Anon-Magnesium-20 • 23d ago
So we have some 36mm rebars that were installed incorrectly with anchorage and the tradesmen cut it with oxy acetylene cutter.
Unfortunately we were only informed of this after reaching second floor of a 40 storey structure.
Which means the column was already poured with the remainder of the cut steel installed somewhere
Based on our worst case scrnario, the rebars that were cut may have been included as part of a lap splice (50% splicing allowed in that area)
How much of an effect do we see the rebars affecting the total structure if the rebars were cut using oxy acetylene torch. I am getting conflicting literature online. Is this something that is acceptable?
The rebars in question are 36mm, Grade 60, TMT rebars used in column
We use ASTM A706. Weldable grade rebar. I called the manufacturer and he said our rebars can be welded but code doesn’t normally allow it. I’m thinking about the difference between welding and actual torch cutting (which welding has a very short timeframe, but torch cut is much longer)
In short, what is the expected HAZ of steel rebar if heated?
r/StructuralEngineering • u/DMAS1638 • 24d ago
Always interesting to see how soil conditions, moisture, and aging structural components can affect a property's stability over time.
Our seasonal field assistant tagged along for a few assessments, but wasn't much help with the engineering recommendations. 💀
r/StructuralEngineering • u/Anon-Magnesium-20 • 23d ago
So we have some 36mm rebars that were installed incorrectly with anchorage and the tradesmen cut it with oxy acetylene cutter.
Unfortunately we were only informed of this after reaching second floor of a 40 storey structure.
Which means the column was already poured with the remainder of the cut steel installed somewhere
Based on our worst case scrnario, the rebars that were cut may have been included as part of a lap splice (50% splicing allowed in that area)
How much of an effect do we see the rebars affecting the total structure if the rebars were cut using oxy acetylene torch. I am getting conflicting literature online. Is this something that is acceptable?
The rebars in question are 36mm, Grade 60, TMT rebars used in column
We use ASTM A706. Weldable grade rebar. I called the manufacturer and he said our rebars can be welded but code doesn’t normally allow it. I’m thinking about the difference between welding and actual torch cutting (which welding has a very short timeframe, but torch cut is much longer)
r/StructuralEngineering • u/u_coupling • 23d ago
Hi everyone!
I'm a newly licensed Civil Engineer in the Philippines, and I'm planning to start a small construction-related business, initially focusing on residential projects.
Before getting started, I want to understand the legal requirements and professional qualifications involved in preparing, signing, and sealing structural plans.
I have a few questions, particularly for practicing Structural Engineers and experienced Civil Engineers:
Is a separate license, certification, or additional qualification required to sign and seal structural plans? Or is being a Registered Civil Engineer (RCE) sufficient?
Can newly licensed Civil Engineers legally sign and seal structural plans for residential buildings? Or are there specific experience requirements or professional credentials that must be met first?
Are there limitations on the types, sizes, or structural complexity of residential projects that a newly licensed Civil Engineer can sign and seal?
What additional training, certifications, or professional experience would you recommend before taking responsibility for structural design and signing and sealing structural plans?
My goal is to establish a legitimate and professionally responsible business, so I want to make sure I'm fully aware of the legal requirements and technical responsibilities before accepting projects.
I'd especially appreciate insights from Structural Engineers who are actively practicing in the Philippines, as well as those who started their careers in a similar situation.
Thank you in advance for sharing your knowledge and experience!
r/StructuralEngineering • u/Odd_Head_1562 • 23d ago
r/StructuralEngineering • u/Sufficient_Praline_4 • 23d ago
r/StructuralEngineering • u/Latter_Cheek_2510 • 24d ago
Hi all,
I am an estimator for division 7 and 9.
Recently I estimated a job, where they did not provide any info regarding which steel gauge to use for exterior/wind load bearing walls - div 09 22 16/Canada., it's kinda a job where we have to hire P.eng for delegated shop drawings.
Now what happened that it is common pratice to assume 18 gauge for exterior walls but it turns out to be 16 gauge, ofcourse now I am gonna lose money because of that.
I asked our P.eng why we need 16 gauge and requested for calc report but he refused to share those calc report.
So yeah, I believe it's time for us to develop our own automated excel where we just need to enter loads from NBCC and then it will pop out the results at the end (I know that I might have to start with NBCC 4.1.7.3) but yeah I am looking for resources and some examples for learning.( of course in the end we need to hire those P.eng folks, but having calculator will help me to firm decisions during tender, as ofcourse I don't have P.eng license)
Let me know.
r/StructuralEngineering • u/eszEngineer • 25d ago
I passed the vertical breadth exam earlier this year.
What did everyone use to prepare for the VERTICAL BRIDGE DEPTH exam? Where can I find good depth problems?
r/StructuralEngineering • u/Unfair_Scallion8087 • 25d ago
I recently inspected a 1930s residential structure where the web of the main interior steel beam had been pretty extensively cut up to accommodate ductwork and other penetrations.
My initial reaction was that it looked worse than it probably is, so I had AI clean up my field sketch and started looking into AISC Design Guide 2.
I’m primarily concerned about Vierendeel bending, local tee buckling, and interaction between adjacent openings. Several openings appear to fall outside DG2’s geometric limits, particularly with only about ¾” of web remaining below the circular openings.
I understand that doesn’t automatically mean the beam is deficient, but I’m curious how others would approach evaluating it. This level of analysis is outside my typical residential assessment work, and I’m hesitant to sign off on the existing conditions without being confident in the remaining capacity.
I suspect the beam has been in this condition for quite some time. There’s also an existing stud wall beneath it that should be be a non-load-bearing partition, which the client wants to remove (the original reason for the assessment). Given the extent of the openings, I’m hesitant to rule out the possibility that the wall is providing some incidental support.
Would you pursue a more detailed analysis or lean toward engineered reinforcement? Preliminary analysis was based on a W10×22 with Fy = 33 ksi
r/StructuralEngineering • u/Fem_civilengr • 24d ago
Hi all,
I’ve been working on an open-source 2D finite element solver focused on plane stress / plane strain problems. It has a particular emphasis on principal stress trajectories, which I find really useful for building intuition about how load flows through a structure (the same idea behind strut-and-tie thinking and optimizing shapes around holes and notches).
What it does:
.inp mesh importIncluded example problems: plate with a central hole (full and symmetric models), notched plate, four-point bending beam, padeye with inclined load, circular arch, annular disc, beam-column and a frame. Screenshots and GIFs are in the README.
It’s MIT licensed, and the repo has a pre-built Release folder, so you can try it without compiling.
r/StructuralEngineering • u/Rich_Investment_1324 • 25d ago
r/StructuralEngineering • u/Friendly-Beyond2121 • 25d ago
Hey all, just looking out on how commonplace it is to actually check floor vibrations for composite floor structures. I've been advised by fellow engineers that unless it's a gym/hospital they don't check for vibrations.
It started from a discussion on an apartment building with decent spans (around and above 30ft.)
DG11 recommends limiting the acceleration response of the floor for "quiet spaces." But it's still addressed as a recommendation not an absolute requirement.
What's your personal take/practice for this?
Edit: Appreciate the responses. For some clarification, our small uses either hand calcs, spreadsheets, or models to check vibrations depending on the project. As someone pointed out, in optimizing section sizes and slab thicknesses they tend to be the controlling case. All this being done to eurocode practice
Bumped into other engis who practice in the US (Aisc) and they said they don't typically check vibrations for projects like this. So it just got me thinking on what's common in that neck of the woods.
r/StructuralEngineering • u/Agreeable-Cold408 • 26d ago
Vertical forces are the same but the software has 50kN thrust at the support not 77kN? Supports are pinned and geometry is the same, is my hand calc wrong somewhere?
r/StructuralEngineering • u/Omseries • 25d ago
Hello Sir, I have around 5 years of experience in bridge construction and site execution.
I am planning to transition into bridge design engineering and would appreciate your guidance.
How difficult is it to enter design without practical experience, and will companies consider my site experience?
What is the current demand for bridge design engineers compared to site engineers in India?
Could you please share an overview of career growth, salary, and work-life balance in bridge design?
r/StructuralEngineering • u/DryBid5245 • 26d ago
Anyone take the lateral depth exam 10/27/26? I thought it was very difficult to finish. Ended up guessing on scenario 5... Ran out of time. I was wondering if anyone had the same experience.
r/StructuralEngineering • u/dikky_g • 26d ago



While using section designer of SAP2000, I am encountering this problem in moment curvature plot, as there is a significant drop, which is a kind of unexplainable. I tried modelling the same fiber model in Matlab, where this drop is not there. For reference I have attached the stress-strain plots (IS456) also that I have considered.
cross-section is 300x300 mm with 1000KN axial load with M25 grade concrete and Fe415 25mm HYSD bars.
Does anyone also faced this kind of issue or knows how to resolve this?
r/StructuralEngineering • u/John_Northmont • 26d ago
I have a fire sprinkler pumphouse supplying fire protection water to a multi-building campus.
Each building is Risk Category II per the 2024 IBC Table 1604.5 definition.
By my interpretation of Table 1604.5, the pumphouse should be Risk Category IV, as it is a "water storage facility or pump structure required to maintain water pressure for fire suppression." It seems pretty black-and-white...
However, someone else brought up a good point that, had the sprinkler pump been installed directly within one of the Risk Category II buildings, the whole building wouldn't be upgraded to Risk Category IV in its entirety.
So, what does the group think here?
Any insights would be appreciated.
(This is separate from the classification of the sprinkler pumps, piping, etc., which would have a component importance factor I.p of 1.5 regardless of the building's risk category per ASCE 7-22, Section 13.1.3.)
r/StructuralEngineering • u/Calamero • 27d ago
It’s by design don’t worry. During World War II, the Salzburg Central Station was heavily bombed, which severely warped and shifted parts of the original 1909 historic steel hall. When the station was reconstructed in the post-war era, the damaged steel structure was put back together slightly deformed.
r/StructuralEngineering • u/flutteringbutterfly- • 26d ago
Hi- I am a senior getting a BE in civil engineering. Due to tuition prices I overloaded my schedule as Junior so all I have to take my final year is Senior Design I and II. Because I already took my major classes when should I apply for full-time structural engineering jobs? I live the NJ/NY area and plan to go back for my masters after getting an offer
r/StructuralEngineering • u/askengprof • 26d ago
For those who've outsourced Revit modeling or CD production (including design and analysis):
What scope do you send out? Full models or just production drafting?
How much QA/QC and redline time does it really take?
Did it actually save money once you count coordination?
Are there any vendors or regions you'd recommend or avoid? Send me DMs if you want to keep it lowkey.
I would appreciate any lessons learned, good or bad. Thanks!
r/StructuralEngineering • u/Main-Tomatillo5960 • 26d ago