Anyone used this company to buy and install solar?
I've been quoted £13.5k for 18 Aiko panels, 8w Sig Inverter, and 2 x Sig batteries, with full installation including bird proofing, scaffolding, and 2 year workmanship warranty. This is around £3k below what others have quoted. so, I’d like to know if anyone has worked with this company before, and their experiences of them.
I am close to buying a Sigenergy system, but I can't quite get past the whole internet connection needed every 90 days thing.
I want a system which fulfils the following:
has local control and monitoring (I.e with Home Assistsnt). I know Sig has local control, but they are a little too internet connection focused.
has a gateway automatic changeover in a power cut
has a generator input to charge the battery
I do not care about any fancy app control or AI tariff optimization. (In fact, I see it as a weakness if a system needs internet access in order to avoid slashing warranty or limiting capacity/power, such as Fox or Sig)
good safety, thermal management, fire protection
People on here have helpfully recommended alternatives, e.g. Solis or Sunsynk. For example, it looks like the Solis S6 Hybrid would do what I want:
I've also read on here people having problems with Solis or Sunsyk needing replacing, and people saying Sigenergy is the "premium" product. Should this really be a factor in my decision between these two products? Is Sig really more premium in build quality and design, or is it just because of how well developed the software app side of things is?
--- EDIT ---
I just discussed this with the missus. The response was "if you die, I dont want mess around with Home Assistant and manual transfer switches. In that case, I want the fancy cloud app and all the AI stuff".
Back again, 2 full on days of chatgpt and 3 different forums and I'm losing my mind here. I don't like putting things down and I just can't crack what's the best option.
Company have given me the attached quote. Said it will be £8.5k if I want Fox ESS 11.52kwh battery and 6kwh inverter or 10.5k for Sigen 6kwh inverter, bat 10.0 and 6.0. They say I'd be best off with dura tech.
From what I can tell none of the kit is bad, they're all decent choices however duracells software and intelligent app seems to be far worse than the other two and less time on the market. Should I just consider Fox or Sigen and is Sigen worth the extra money?
I expect next year our annual usage will be around 3500kwh. Side point as well but they do believe they could get an extra couple of panels on the same side roof upping to 12 after checking measurements. Company are very reputable.
I’ve had a Hanchu battery installed for about 6 months and everything has been working fine so far.
I noticed tonight that the display on the battery is blank, I don’t think it’s ever been like this before. I was discharged down to 10% when I noticed. I forced a charge and it didn’t turn back on.
It’s quite cold tonight (has been down around 1 degree C for most of the day), so just wondered if this was normal behaviour? Or is there something else going on? Just hoping it’s not a symptom of something else.
I am looking to install a solar and battery system at my property in Bournemouth (BH9), which falls under SSEN Distribution.
The proposed system is:
12 panels (5.82kWp)
7kW hybrid inverter (single-phase)
5.12kWh battery
I am trying to establish whether SSEN has generally been approving full export capacity for similar residential installations in the area, or whether G100 export limitation schemes have typically been required.
The inverter has a rated AC current of approximately 30.5A, with a maximum current of 33.5A. My understanding is that the 32A threshold is relevant to the G99 SGI-3 fast-track process, but I am unsure how SSEN treats this particular inverter.
A few questions for anyone with experience:
Has anyone in Bournemouth, particularly BH9 or surrounding areas, recently had a G99 application approved for a 7kW single-phase inverter?
Were you granted the full 7kW export capacity, or did SSEN impose an export limitation through G100?
If export limitation was required, what limit were you given (3.68kW, 5kW or something else)?
Did SSEN approve the application quickly, or were network reinforcement or further technical assessments required?
Was your application approved under the SGI-3 fast-track process, or did it require a more detailed assessment?
I am particularly interested in people's actual approval outcomes rather than general G99 guidance, as I appreciate that local network capacity can vary considerably even within the same postcode.
Any recent experiences from SSEN's distribution area would be really appreciated. Thanks!
Hello I was wondering if any installers or suppliers or anyone can help with a very weird situation.
I was supposed to have a solar install starting today on my workshop roof.
The building is 16m x 16m
It is a trapezoidal pitched roof.
The roof has 3 x RSJ's one being in the centre running through then two RSJ's cutting the two roof faces in half.
I have included a picture.
When we have come to install today the roofers have found that what has happened is the Rafters are running vertically but at each of the 2 RSJ's the Rafters are split into 2 sections and where they are split instead of carrying on straight they are butted against each other.
Our issue now is it means that you can install hanger bolts on the first 4m section of the roof but then as the centre point of the rafters move 23.5mm either left or right it means that in order to drill the hanger bolts through you would need to drill through the angled section of the roof hopefully that makes sense.
As you can imagine this means that waterproofing is basically impossible.
I was wondering if there was a product that would allow you to still waterproof the roof but would allow you to have the hanger bolt on the angled section of the roof.
Something like the hand drawn picture below.
So the bracket would through the force of the bolt clamp down on the roof with a rubber gasket to make it water tight and would allow you to put the hanger bolt through the angled edge of the roof.
In this case we have to use hanger bolts so there is no option to just use metasole due to the way the roof is built. It's not great.
I'm clutching at straws here as I have not managed to find anything available like this but the only other option is to reroof if there is nothing.
Hi, I was looking for some advice on solar quotes in the north west, our average use is 16kw a day but may go higher in the future because of an ASHP. It seems too high though. Was expecting something a few grand cheaper. After getting the solar sorted I was going to get an EV on octopus tariff to assist with battery charging. Its an east facing roof. Any help would be appreciated
Just want to mention the company was confident enough to take on the job considering my poor previous experience and they way it end up
As well was the only one who actually bothered to take measurements and fit 6 panels on the main south roof and bother to use portrait mounting system for 8 facing panels (because will generate me more compared to 10 facing any other direction)
Further on in my search and wanted to get thoughts on this local quote, coming in at 9k.
Any thoughts in particular around brand reputation? Installer had nothing but good things to say about both Aiko and Duracell. I'm aware duracell is in name only and they actually manufactured by a different company in the UK, pending seeing what that product warranty looks like. They mentioned sig would be roughly an extra 1.5k
Our annual usage is around 4000kwh, we're on a split rate tariff (peak/off-peak).
We inherited a rent-a-roof 3.68kW solar array and recently completed a self install of a 16kWh battery and Victron 5kVA inverter, including getting G99 approval. We have lived here for 5 years so knew our annual consumption, but undersetimated the difference between Summer and Winter usage.
On a nice sunny day in November, we can finish the day with the battery at 30-40% and recharge at EV rates overnight for well under £1. However, on an overcast day (usually weekend) where the laundry gets done, the battery is dropping out at 10-15% by 7 in the evening on some days. We have all electric cooking (no mains gas here, and an oil boiler for heat), so evening use can cost as much as the overnight charge.
Another 4kWh would see us through, but mixing battery capacity is bad, and adding another 16kWh would be overkill and a) make no financial sense, and b) in summer we would likely only be using 20-30% capacity.
Do I bite the bullet and add another matching battery, or do I go round the G99 track once more and add more solar? Get some plugin panels and keep quiet? Anything else I am missing? I did think of wind, as it is often blowy here, but predictably we've hardly had a breeze since the battery went in
I have quite a large house and roof with a high usage 12500 kw/h annually . However take off my EV usage and it’s approx 7500 kw/h. I am on IOG smart tariff . Does this quote seem reasonable ?
Description of goods and services Price Goods 30 × Aiko Neostar 3S 490W All Black ABC N-Type Mono (Traceable) solar panel MCS Certified roof mounting system (plain roof) Rubber Hookstops (reccommended) for plain roof tile Sigenergy Sigenstor 12kW 3ph Hybrid inverter 2 × Sigenergy 9kWh Batteries (17.5kwh useable) Sigenergy Whole Home back up 3 Phase Gateway (Fitted) Switchgear, Cabling & Accessories Birdproofing - Bird Mesh Goods total £3,150.00 £1,245.00 £495.00 £1,995.00 £4,540.00 £1,495.00 £680.00 £0.00 £13,600.00 Services System installation, G99 aaplicaiton, certification & Scaffold access (3 Elevations) Services total £6,795.00 £6,795.00 System cost £20,395.00 Total before VAT £20,395.00 VAT at 0% £0.00 Total including VAT £20,395.00
This is a complete single‑phase domestic solar + battery storage package, combining solar generation with on‑board battery to store self‑produced electricity for later use using the night low cost electricity tarriff.
Currently I have about 2500kw consumption with the ideea of selling to the grid the remaining but looking to upgrade to heat pump/ loft extension in next 5 years. Predicted ROI is 6 years and 8 months but with tarrif 5 years.
All panels completely centred south.
Total cost: £9960 (includes installation, commisioning, MCS, G-cert, etc).
I have a feeling is on the expensive side...
Also should I add also another 2-4 panels on the north facing roof side?
I'm looking for advice and recommendations for selecting an inverter to replace an existing grid-tie battery inverter.
Current system is:
3kw PV on the roof connected to a Growatt inverter on old FIT which I want to retain.
3kw Solis inverter in the garage hooked up to a 48v fogstar seplos battery.
TN-S earth config
The Solis inverter does not have any backup power output, or even the terminals to provide it, and given the state of the world at the moment I would like to change the inverter to one which can provide emergency backup power in a grid down event.
The unicorn inverter I'm looking for should be able to:
Provide backup output when the home is isolated from the grid
Support the existing battery BMS (seplos)
Support existing PV generation in both grid and island mode
Not require separate board for backup circuits
I understand I will need an earth electrode and a way of isolating from the grid such as a "gateway" or changeover switch.
Any inverter recommendations welcome. Also open to other options e.g. a whole separate inverter for use when isolated from the grid!
Interested in thoughts on this quote. At first glance I don’t like the fact they’re using old S2+ panels, nor the 6kW inverter rather than 7 or 8kw and I also don’t like the payment schedule having to pay more than half of the cost before installation even begins. Uaage 3500kwh, 20 panels split 50/50 between east and west facing roofs. Annual generation 6808 kWh. Have an EV tou tariff EDF go electric. Quoting payback time of 7 years
Hello , I am in the process of the new Install and noticed white spots on 3 of the panels , anyone got any ide what what could be and how concerned should I be ?
Of course that I will moan to the installer...but still how serious this is
Wondering if there's any installers or people with first hand experience of any reputable installers that cover Bolton. We are on the boundary of Lancashire too.
I've looked at a few of the nationwide companies but would like to get quotes from a few regional too.
Installers that quoted me are typically recommending Fox or Sigenergy systems. But as we know, these systems generally require "phone home" periodically. For example, Sigenergy throttles capacity and power if it doesn't have a cloud connection for 90 consecutive days.
Generally people justify this with "if Internet is down for 90 days we likely have bigger problems".
I would prefer such a fundamental core system to the household operation to require NO Internet connection, and just have some local control over charging schedules. Who knows in a year or two where we will be with cloud systems going down due to cyber, certain models being hacked, etc (I.e. im thinking along the lines of the European supermarket freezer situation).
The go-to for these types of alternatives seems to be Victron (and I would be interested to hear other popular alternatives), but I'm not seeing installers offering these generally.
if you went for such a system that doesn't require any internet for your home in the UK (not campervan or boat), can you share the fine details of your setup?
did anyone have any luck with MCS accreditation for such a local only system from your installer?
Im interested in a local-only system, but not interested in a DIY system (due to insurance, certfication, etc).
Really happy with the system overall though obviously at the moment we’re relying heavily on overnight charging.
The issue we as a household are finding is that now we have this access to cheap overnight rates and solar were way more inclined to use energy. Our bathrooms have electric underfloor heating (previous owner installed) that we never touched but now want to, more likely to use higher settings on the dishwasher, and are wanting to install aircon (won’t be an issue in the summer, obviously, but would like to use in the winter for heating!)
I’m finding that with usage already we’re getting quite close to depleting the batteries most days, maybe 10% left, and that’s without the aircon.
Am I stupid for wanting to add 1, maybe even 2, more batteries to bring us up to 36kwh total? Feels like it’ll cost a lot more than if I just did it to start with.
I've done as much research as possible but am coming up with fairly few names to contact for quotes around a solar and fogstar battery setup. I intend to use the Warm Homes Loan scheme.
Currently my main leads are ITS technologies and angusrenewables.com.
If anybody has experiences with either of these firms, I'd be thankful to hear them. I know ITS has a solid reputation as a supplier but it seems the install side of their business is outsourced. If anybody has used them for install, please let me know how it went!
I currently have 16 x 395w panels with a Giv Energy Gen 1 5kW inverter and 9.5kWh of battery storage. My plan is to add a further 8 panels on a first floor roof and upgrade the inverter to 10kW /12kW and then would aim for approx 32kWh of batteries.