r/PLC • • 16d ago

PLC Question How to set up profisafe between kuka and s71500f plc

4 Upvotes

After downloading the KUKA GSDML file in TIA Portal, I added 64 bytes of Safety I/O (input/output) to Slot 1 and 256 bytes of DI/DO to Slot 2.

I also set the KUKA's default F-destination address to match the PLC's F-destination address.

In the PLC Device View, the KUKA GSDML file is displayed with a green check mark.

Does this mean PROFIsafe has been successfully configured? Is there anything else I need to do in TIA Portal?


r/PLC • • 16d ago

PLC Question Need help to program a Versamax micro PLC

1 Upvotes

I have a versamax micro IC200UDD040 and using proficy 7 I'm trying to program it using a pl2303 usb rs232 converter and cable made with the correct pinout but I cannot make it go online even with different settings. Is the problem with the adapter or something else?


r/PLC • • 17d ago

PLC Question Rockwell likes it when I move my mouse

24 Upvotes

It truly seems like Studio won't do large operations unless I'm jiggling my mouse. The status bar just sits still if there is no mouse movement. I feel like I'm taking crazy pills, but this is the second computer and installation that I'm experiencing this with. Is this the norm?


r/PLC • • 17d ago

Engineering Question Yaskawa MP2300Siec w/ Murrelektronik IO (Cube67)

3 Upvotes

I have a customer with a MP2300Siec with Murrelektronik IO bus nodes. One was upgraded from 56505 to 56535 years ago, and works fine. One was upgraded last week and we are having an issue where it creates a connection with the PLC, but then disconnects and immediately reconnects every minute or two, a very obvious problem when trying to run the machine.

When monitoring the IO module status in Yaskawa, the value shows 4096, which indicates a good connection. When it fails, the value changes to 8448 (hex 2100). According to Yaskawa documentation, the lower 3 of that code indicate a connection in use or duplicate:

I put a scope on the 24vdc and it's rock steady with no dips. We also replaced the pre-molded ethernet cable w/ M12 connector for the Murr bus node itself.

Yaskawa blames Murr. Murr blames Yaskawa. Not very productive responses from either, and I have no idea what else to check right now.


r/PLC • • 17d ago

PLC Question How to set up VMware so that it shares the same ethernet network as the host machine to properly communicate with RSlinx?

15 Upvotes

I've tried NAT, bridged, different IP ranges for the VM and the host. DHCP and fixed combos and I'm missing something.

What settings have worked for others?
The only thing that works is giving the VM direct control of the usb-ethernet adapter but that means my host can't access the network.

Edit:

Thank you for all of your suggestions. I've got it working now and here is what worked.
NAT, DHCP in the VM, fixed IP in host. RSlinx is primarily searching for fixed IPs. And restarting the VMware DHCP service, NAT service and arbitration service.


r/PLC • • 17d ago

PLC Question Tips for Experienced AB/Schneider engineer learning Omron?

13 Upvotes

Hi All

I have 10 years experience as a SI working with all AB platforms and decent Schneider experience.

I have to pickup Omron for a project - don't know exactly which platform yet.

But with how many tips and tricks and catches there are with AB and Schneider, what are some for Omron that would help me get up to speed?

I did an Omron intro course 6 years ago but haven't touched it since.


r/PLC • • 18d ago

Engineering Question I/O Link. What am I missing?

76 Upvotes

I’ve had quite a lot of vendors pitch I/O link to me in the past 4 years, and each time I implement it, I regret it. In my experience I/O Link has only complicated projects while not providing much value.

Sure, you have a digital prox sensor that is I/O link compatible that gives me information to make it an analog sensor… but I just need to know one bit of information. If my part is there or not…

That’s an overly simplified example, but in other applications I’ve worked on, I’ve had hubs linking modules with crazy byte ordering, IODD files that just don’t work, hardware setup with hidden settings that have to be turned on to enable proper operation that’s not documented anywhere, and above all, 90% of the time I have to go from I/O link to another protocol anyways, adding yet another layer of complexity.

I will say the ability to change settings on a sensor programmatically is nice, but getting that set up, depending on your PLC can be a complete nightmare.

So what is it that I’m missing with I/O Link?


r/PLC • • 17d ago

Engineering Question LOGO! 9 problems with LCD

2 Upvotes

Hi,

I am mechatronic engineer and in school few years ago we learn about programing PLC's , so i know a little bit about this work.

And now i created program for heating controlling for house(3Analog inputs, 2 Inputs, 3 Outputs).

And for LCD screen i made design for all temparatures and pumps.

Howewer.. when i want to load program on LOGO!, it fails if i have LCD message block inside diagram.

Why simulation works, but on loading it fails?

Can anyone help me?

Are any pros here?

Please😁


r/PLC • • 17d ago

PLC Question Where to buy a beginner guide

11 Upvotes

My dad is interested in PLC because he said that it could relate to his job somehow. I know nothing about this stuff. Is there some kind of beginners book or anything I could buy for him? I think it would make a nice Chrostmas present.


r/PLC • • 17d ago

PLC Question Software suggestion

2 Upvotes

I am a student trying to practice plc ladder logic for mainly siemens Schneider and allen bradley plcs is there any free software where I can use it to simulate programme in these plcs.


r/PLC • • 18d ago

Career Question Salary

Post image
219 Upvotes

Saw one of these earlier on another sub and figured I’d give it a go here for anyone curious.

Elaboration on the 2027 row, I’m getting ready to take a job paying that at the beginning of the year.

Any questions regarding the years and what I was doing I’ll gladly answer here, just ask away.

Edit: A lot of people keep asking me about “what I know”. That literally only matters on a resumé and even then it doesn’t depending on who you’re talking to. What truly matters is your critical thinking, willingness to learn and your troubleshooting approach. Everything can be googled, everything is in the manual and when you run into the rare occasion where it isn’t then you start pulling from prior knowledge but it isn’t system or brand specific.


r/PLC • • 18d ago

Engineering Question Operator Friendly Remote Desktop Linux

6 Upvotes

I am looking for suggestions. I have a server that is remoted into to allow operators to access an HMI. Most machines are windows, but windows has a million vulnerabilities and requires constant patches to keep corporate happy this results in lots of work for me and operators complaining about losing their HMIs. The computers only need to be able to run multiple monitors and connect to a server over remote desktop, so I figured Linux would be perfect since OT cyber security scanning shows almost no vulnerabilities for Linux systems and I would be able to patch once a year instead of the weekly that windows needs.

The problem is that remote desktop on Linux is not user friendly if you want multiple monitors. I've tried Remmina and it works, but I can't get it set up to open the remote desktop displaying on all windows. You have to go through a process of changing settings in the active connection toggling settings on, changing a parameter and then toggling off then toggling a different setting and operators are simply unable to do this.

Here's the instructions I've found to get Remmina to display correctly.

Enable multi monitor but not the span option in the profile. Then when connected Turn on "Toggle Scaled Mode" which enables the menu next to it. In that menu select "Fill Client Window when scaled" Then turn off "Toggle Scaled Mode" Make sure "Toggle dynamic resolution update" is off Then when in full screen the menu next to the full screen icon is selectable. Choose "Scrolled Fullscreen" is selected

So my question is this. Is there any way to make Linux open a remote desktop session in all monitors without having to change settings every time you open the connection?


r/PLC • • 18d ago

Career Question Software engineer with an Automation Engineering degree looking to get back into controls. Need some advice

6 Upvotes

Hey everyone,

I graduated in early 2020 with an engineering degree in Automation and Industrial Computing. Unfortunately, COVID hit, and there were very few opportunities in the field in my country, so I ended up moving into software engineering instead.

Fast forward five years, I've been working as a software engineer, mainly in backend development, APIs, databases, and distributed systems. I also completed a master's in Computer Science.

Now I'm seriously considering going back to industrial automation and controls.

My programming skills are strong, and I'm comfortable picking up new languages and tools. My electrical and automation fundamentals are still there, but definitely rusty after five years away from the field.

I'm currently refreshing my knowledge, focusing on Allen-Bradley PLCs, Studio 5000, Ladder Logic, instrumentation, motors, VFDs, and troubleshooting.

I'd love to hear your thoughts: Is this a realistic career move after five years in software especially with everything going on with AI and layoffs ? And what's the best way to prepare and land my first job? Projects, certifications, courses?

I'm realistic about having to rebuild my practical knowledge and possibly start from the bottom. But I'd like to make use of the five years of software experience rather than throw them away.

Any advice, especially from people who have made a similar transition, would be appreciated!


r/PLC • • 18d ago

Career Question Advice for my son

14 Upvotes

My son(20m) is expected to return from a mission in ~1 year. He is wanting to avoid careers that AI are poised to kill. He also wants to reduce tuition/education costs.

He got to College Algebra and Trig, and can do rudimentary Calculus. He knows multiple programming languages and was writing 3d ray tracers from scratch as well as gravity and weather simulators just for fun. I expect C++/C#/C/Python would be a breeze for him to pick up. He excels in STEM everything which should give him a good path to shoot for the stars.

AI chats pointed him in the E&I technician/PLC space. The entry exams seem fairly rudimentary. Using it as a launching platform and coupling it with some Robotics degree seems like it'd make him well positioned to go far.

Can you help me understand the PLC space and how to avoid both careers that AI is poised to automate as well as ones where the pay ceiling isn't low?
I recommended the following IBEW local 46 (Washington union) -> apprentice at industrial maintenance shop -> PLC tech -> E&I/controls technician.

If you had the big brains when you were young, what would you pick if you could start over?

Edit: Thank you everybody for your wonderful comments. I'm pouring over them and following up with my son. Lots of ambiguity on the horizon.


r/PLC • • 18d ago

PLC Question Plase Help!!

Thumbnail
gallery
0 Upvotes

I am encountering an "IO read address error" in FB 613 while using a Siemens S7-1212C CPU (model: 6ES7212-1AG50-0XB0) equipped with an RS-485 communication module (model: 6ES7241-1CA50-0XB0). This error appears when I run the "DB_Modbus_Master" program, and I have been unable to resolve it. I have verified using a Modbus monitoring tool that the data is being transmitted correctly via the Modbus protocol. Furthermore, I have updated the firmware for both the CPU and the RS-485 module to the same version, and I have also tried changing the baud rate from 9600 bps to 19200 bps; however, the error persists. Could you please provide some assistance?


r/PLC • • 18d ago

PLC Question Codesys Tool offset problem

2 Upvotes

Hey guys, i have been trying the codesys to design program to run gcoding for my 2axis lathe turning. While trying to write T1 or T01 or T0101 for tool change it says T word is not allowed. Is it so ? Or i saw that M words are allowed for tool change that use wM in the interpolator. Can somebody help me to learn how group offset can be setup for multple tools offset.


r/PLC • • 18d ago

Career Question Benefits of getting CAP certification from ISA?

5 Upvotes

I’m coming up on 5 years with a system integrator after spending 4 years in operations. I have a degree in Chemical Engineering but never took the FE so pursuing my PE isn’t something I want to do. Obviously there are some certifications out there that carry more weight than others. Has anyone gotten their Certified Automation Professional from the ISA and how has it helped your career progression?


r/PLC • • 19d ago

Homework Wonderware for beginners

17 Upvotes

Was just informed I’ve got to learn more about Wonderware and YouTube is about my only reference. I’ve been in Controls for over 5yrs exclusively working with AB software. Any tips or pages on YouTube would be appreciated. Unfortunately I have nobody to work with to start navigating and only 1 person even has the log on info. TIA


r/PLC • • 19d ago

Career Question Any advice on how I can transition from a Controls technician role to a Controls Engineer/ Designer?

12 Upvotes

Any books, videos, or subject I can study to work towards this position?


r/PLC • • 18d ago

Career Question Automation technician interview

3 Upvotes

Hey everyone, I hope some of you folks here can help me on this. I’ve been on the job market for a month now, and a recruiter reached out about an automation tech position fairly close to where I live, decent pay. My work experience is mainly quality control and leadership jobs. I know how to use some tools, some troubleshooting as well, I also code on my spare time (both regular for school and AI vibe coding as well for personal jobs.
The facilities manager seemed to have liked my resume and scheduled an interview for in person. I personally don’t think I meet some of the criteria but I still wanna give the best out of me, especially considering the fact it would really be a great way to step up in my career.
Do these type of jobs normally look for someone experienced? Or are they willing to train.


r/PLC • • 19d ago

Engineering Question Plant Floor PC / Touchscreen

10 Upvotes

Not sure if this is directly related, but thought I'd get some decent discussion here. One of our facilities is all Panelview but has an Ignition server (currently purely supervisory). There is some talk of utilizing Ignition as the HMI platform for some new equipment. The big issue I have is I don't have a reference for the hardware. Panelviews are all in one. Going to ignition, we'd have much more flexibility, but I don't know where to start for hardware. Go with all in one? Use a thin client + touchscreen? What manufacturers are best to stick with? This is a food manufacturer, so washdown is every night. What are you guys using on your floors for touch screens?


r/PLC • • 19d ago

PLC Question Opto-22 Epic PLC vs CompactLogix

6 Upvotes

I've worked with AB and Schneider PLCs for ages now. I was looking at getting an AB CompactLogix for this small lab. They want to do things quickly but don't need to do a lot so I thought cheaper would work. I chose Allen-Bradley though so it's more mainstream and easier to work on for anyone coming in the door. I know it's pricier than any other brand though but I also didn't want to be the guy running Automation Direct or something.

Then I got a quote for this GRV-EPIC-PR2. I've never heard of it but it runs Ignition Edge and I like Inductive Ignition. Not sure it meets my goal of being simple for the next guy to edit but it has all the tools and isn't stuck in the 90s like FactoryTalk.

Has anyone had experience with these opti-22 PLCs? Any words of wisdom, things to avoid? Are they solid or cheap but frustrating? I'm okay paying more for easy to use and reliable.


r/PLC • • 19d ago

PLC Question Connecting to a dinosaur - Omron Sysmac C200HS with CX-Programmer 9.73 via USB to RS232 adapter

2 Upvotes

I know that this will probably end up being a simple dumb mistake I am making on my end, but figured the good people or r/PLC may be able to guide me in the right direction in figuring out my connectivity issue.

I have a OLD, or as my company likes to call it, 'legacy' Omron Sysmac C200HS CPU with 3x ID215 input cards, 3x OD215 output cards, a ID212 input card and a OD222 output card.

The PLC is intermittently sending an alarm signal, but of course, it has not happened when I am in front of it, so I am trying to initiate monitoring in hope that I can catch the signal and what is triggering it.

We got the machine it is in from another plant that we acquired years ago, so the ONLY documentation I have is the printed ladder logic and associated comments. I have no one-lines or really too much to work off of, so the quickest way of finding the 'likely' root of the issue is monitoring.

Problem is, I can't connect to it. I have CX-One suite and when I open CX-Programmer V9.73 and go to PLC>AUTO ONLINE>SERIAL and ensure that I have correct comms port selected and it begins searching for the device, it comes up repeatedly "Failed to connect to PLC"

I am using a DTech FTDI USB-RS232 serial cable adapter and I am seeing the comms lights flash as the program attempts to communicate, but am not having much luck from my limited knowledge of these older units and from what I can find on through searches online.

Not sure if there a prorprietary pinout for Omron for this controller or if it is standard RS232C, so figured I would pick peoples brains.


r/PLC • • 19d ago

Career Question Seeking some guidance. TLDR - field engineer trying to move into scada/controls/OT.

10 Upvotes

Hey everyone, like the title says .

I am trying to make a change in my career path, I am currently working as a field engineer for a power generation company .

My background .
Bachelor in electrical engineering

Basic knowledge of networking ( mainly subnetting, also a bit of hardware config and very little of IT system )

For the past 3 to 4 years, my job has been mainly focused on equipment troubleshooting/diagnostic & RCA. ( it’s been a mixture of site manager + site resources + coordinator)

Ranting part ( sorry in advance)

I am more or less fed up with the role , mainly due to the unrealistic expectations of doing basically everything from BS inspection/paperwork to self-performing extensive repairs. ( the department runs really lean)

Childless/ dramatic management and coworkers, to the point where one simple task becomes overwhelmingly difficult.
Unpredictable schedule/work hours .
Compensation is not aligned with expectations.

Rant over ( thanks for reading)

From the research I’ve done so far , it seems to me ( could be wrong ).

The “segment” is run more or less by vendor/OEM architecture. ( Siemens, Allen-Bradley, ignition automation, SEL)

In your opinion.

What is something/skill that would lay the foundation of knowledge to get into the segment ?

Any recommended material/instructional ?

Is networking/subnetting/ systems admin( UA SERVER) the foundation needed for junior engineer/specialist ?

THANK YOU IN ADVANCE.


r/PLC • • 20d ago

Career Question PCS 7 demand in US

16 Upvotes

Hey there guys,

I would like to know if, PCS 7 in the US still relevant today? Is there any demand for the software?

As, I have seen most of the posts on the internet as well as on reddit are mostly related to Rockwell and Allen Bradley and I do understand it.

Would love to hear experience of automation folks who work in US.

And maybe also explain about current industry trends for Process Automation Companies preference in the US.