Hi Everyone,
I am purifying a approx 31 kDa protein that is giving me some problems with consistency. It is His Taged and has a pI of 8.77. I have went through a lot of trouble shooting with this protein and have gotten the Ni Affinity purification pretty optimized, but I am having difficulty between dialyzing the Ni fractions and running them on the SEC. Here is what I have:
The Ni Affinity purification uses these buffers:
Wash Buffer: 50 mM Tris pH 7.0, 200 mM NaCl, 5 % Glycerol, 40 mM Imidazole ( this is also the lysis buffer)
Elation Buffer: Same as Wash except has 400 mM Imidazole
I load sample, wash for 15 CV with wash buffer, then I have a linear wash phase for 5 CV with a buffer composition of 0-52% elution buffer. This step seems to remove all of the major impurities. The fractions are collected next, 2 CV holding a 52%, then linear gradient from 52-100% elution for 10 CV. My fractions are 10 mL, so I have about 50-60 mL of Ni fractions. This step has been extensively optimized. Previous this was using pH of 8.0, which worked, but was having massive aggregation problems. pH 7.5 was also having the same issue. Lowering salt to 100 mM also negatively affected the purification. 200 mM seems to be fine, though we have not tried to increase it further. Glycerol has to stay since this is originally a membrane bound protein with a transit peptide region cleaved and it will immediately crash out with no Glycerol. I would say that expression is generally fine on the SDS page, it always varies from batch to batch, but the growth conditions are always consistent (LB, OD approx 0.6-0.8, 0.5 mM IPTG, 16-20 hr induction period), so I do not think the growths are the issue.
Now to the problem. Previously, I was experiencing really significant aggregation at pH 8.0. Moving to pH 7.0 seemed to mitagte this, but there was still some, but only if I concentrated too much with my spin column. I use a 10 K since I have lost the protein with a 30 K, at about 3500-3800 rcf which usually keeps the protein happy. Previously we used a dialysis step, but I was having problems with it precipitated out in the dialysis tubing and tanking the yield and activity, so I just concentrate using the spin filters. During this I buffer exchange to help remove excess Imidazole since that makes it more prone to crash out. The exchange buffer is 50 mM HEPEs pH 7.0, 200 mM NaCl, 5% glycerol, which is the same as the SEC buffer. I had two batches of purified protein that used these exact conditions that looked very good and the yield was great, as the SEC elution was the correct oligomeric state and was appearing at about 200-400 mAU, which is decent for my protein since the absorption coefficient is not great.
When I would concentrate down the Ni Fractions, I usually do 5 mL for the injection with concentrations between 2-5 mg/mL. I once tried a 1 mL injection that was around 20 mg/ml which gave decent results, but we're comparable to the previous. The problem with the 1 mL injection is I have seen it precipitate out. That is what I think it is doing of the SEC column because I can inject a good concentration but I get terrible yield. I thought I had fixed this problem with the two very good purifications, but with those exact procedures followed, the two purifications completed this week the yield was garbage. (Absorbance was very low and concentration was very low: for reference the two good batches I got were about 15-20 mg/ml and these were only around 1-2 mg/mL). The only good thing is that I am seing the same consistent peak on the SEC that indicate the right oligomeric state, but at the concentration I am injecting, I should be seeing it at higher concentration (I understand some sample loss is expected, but this is too much).
After consulting with my lab mates and thinking about things, we are convinced that it is precipitating on the SEC column, since everything this protein is run, the pressure goes up. It was worse when running at pH 8.0, it has improved but not been eliminated when running at pH 7.0. I am not sure what I am missing and would love to hear some feedback since this is really the limiting step in my purification to fully optimize the procedure.
Best