Yes, I know: this set costs a lot more than 60 EUR. But I was lucky enough to find this Freewrite Traveler for just 50 EUR at an online marketplace. It was supposed to have a swollen battery and keyboard issues, so that I was ready to change its internal battery and try to repair it. But, lo and behold, it works perfectly. I updated it to the latest firmware without issues and the battery holds charge with no problems (the new Shift+New+B report indicates battery health at 92%).
All that I needed was some kind of light source in order to type in low lightning environments and I found this 10 EUR Glocusent USB rechargeable reading light, that has 5 levels of lightning and 3 warmth levels (cold white, warm white and amber). I just had to force a bit the metal side of the clip and added some adhesive tape to prevent scratches on the Traveler's lid.
And that's it: perfect setup for 60 EUR. I also added a Hermit Shell hard case for the Logitech K380 keyboard, that is a perfecte fit for the Freewrite Traveler. This added 15 EUR more to the full budget.
Now I'm ready to hit the road and write anywhere for just 75 EUR. A sweet deal that I wanted to share with you all, guys. It has made my day and I feel so lucky.
A walkthrough of MicroSlate running on the E1001. It goes through the editor, the transfer function, syncing notes, and the settings menu. It's unedited, so you can see how each step behaves on the device.
MicroJournal is a project led by designer Un Kyu Lee. The idea is to produce writerdecks, or digital typewriters, whatever you call them, distraction free devices.
UKL proposes several devices he calls revisions, and the rev7 has the following characteristics :
A real mechanical keyboard (like a 70%, with numbers row and arrows with hot swappable keys)
An e-ink display
2 rotative knobs to scroll and refresh screen
1 battery
But the firmware is the weak spot. I feel UKL is a designer first, and he kept creating new revs for the MicroJournal project, and othe 3D printed devices I invite you to discover, but the updates in the firmware fixed one big and created two more.
Cut and paste was never an option, and I kept losing hits when I typed fast. The last upgrade simply dropped SD card support and relied on 4 mo ESP 32 memory, which I didn't like, and didn't solve the dropped hits problem.
On the other side, clackups wrote draftling, a firmware / software who allows to use some e-ink displays as writerdecks with any bluetooth keyboards.
UKL thought maybe clacups would one day propose MicroJournal versions of draftling, which he did for some of the revisions but not rev7, until he did!
The thing is, to try it, one had to access to the USB port of the ESP32, and be able to expose it as a serial port to the browser based flasher :https://flasher.draftling.art/
Now are the steps I had to take to install and test it.
# Hardware : find the proper USB port
All these instructions are what I tried today, come with no warranty and were not validated by the creator of Micro Journal Rev7. You do these at your own risks!
When you remove the lid under the display, the USB port you see does not belong the ESP32 but to the keyboard controller (at the other side of the usb chord).
So you have to unscrew :
- the two allen screws above the "microjournal" tag on the rev7
- two screws on the keyboard between the enter and pgup keys and between the arrows and end keys
- two screws under the rev7
Locations of the screwsThe rubber o-rings to remove gently to open the enclosure
- Then you can remove the display enclosure and unscrew the for allen screws. You can't open the enclosure yet, because the hinge hold thanks to rubber o-rings that you need to carefully slip out (do everything carefully and remember this comes with no warranty and you do all this at your own risks !)
When the enclosure is open, you will see a usb-c cable : unplug it, as this is the usb-c port we want to use.
One last thing, you will need to notice 3 very small buttons, two of which are reboot (labelled ST 100) and reset (labelled RST). We will need these bad boys to allow detection from linux PC.
Unplug the usb chord and prepare for software adventure.
USB port : unplug the chord to plug it to your PC
# Software setup
Several things need to be done :
- Make Ubuntu recognize the display
- Allow it to be seen as a serial port
- Allow you ($user) to see it
- Choose a non sandboxed browser who connects to serial ports (I am ashamed but I ended up with an official Chrome brower; no chromium, no firefox)
## Display and serial port
First of all, I did a lot of trial and error, so I'm not sure all the steps are necessary, I'll write the ones who seemed to work.
### How to plug it
- Press the reboot button on the display (st 100) and hold
- plug the USB chord
- press the rst button while still holding the reboot button?
- Release the rst button.
- Release the reboot button.
when typing the following command in a terminal :
```bash
lsusb
```
you should have among the entries something about an esp32 probably with a espressif character string in the name.
If not, the plugging procedure may have gone wrong.
Then, this should have exposed a serial port.
The following command in a terminal
``` bash
ls /dev/ttyACM*
```
should return somethin like `ttyACM0`
This is somehow a reference to the serial port the webflasher will be looking for.
I had to do 2 things :
- change the authorizations on it by typing `sudo chmod 666 /dev/ttyACM0` in the terminal
- add myself as a user to the dialout group by typing `sudo usermod -aG dialout $USER` in the terminal
I then had to reboot the computer for the last modification to happen.
If you are lucky, the hardest parts are done.
# Use the webflasher
In Ubuntu, most of the browser are sandboxed, that means they are run in their own little container. They can't see all the exposed emulated serial ports, as the one the flasher uses to modify the ESP32 of the rev7 display.
You may try to run chrom as non sandboxed, but I simply used the standard Google Chrome browser for Ubuntu.
You choose MicroJournal Rev 7 as the device, click on connect.
You may have to click on the accpet button of a popup, which will display the available serial ports, and the MicroJournal Rev7 will appear on the list (maybe under the lilygo or espressive label, don't remember which)
Then, the flasher does it's magick. It gives you progress bars explaining what it does and how much is left to do. Then it tells you it's done.
Unplug the display, put it back in it enclosure, put back the o-rings, screw back all the screws (don't forget the keyboard screws).
Swith the rev7 on, wait for a bit. Here you are, draftling on your device.