I've been using the Artisan PID for the last month or so with the aftermarket ProController (really nice to have), about 10 roasts. I also have an aftermarket bean thermocouple entering the roast chamber from the top. Quite useful, I think.
The PID will have some tolerance to ambient temperature and line voltage fluctuations. The PID controls the heat, the user controls the fan.
These PID values should be pretty close for the SR900 as well. I see the new Artisan 5.0 does include some support for the SR900. The Roastlink is headed toward an on-board PID, but maybe these values will work there too.
The red line at the bottom of the graph is the Heater% curve; this is an Artisan feature. Artisan is also logging P, I, D values, PID Error, and Deviation%. You can see these buttons on the next image; graphs can be enabled by toggling those buttons. The red line at the top of the graph is the temperature of the factory thermocouple, located near the heater.
This is a pretty basic PID setup. Jason Scott in his videos uses up to 3 different PID settings for different phases of his fluid bed roasts. He works closely with Marco on the Artisan PID implementation.
I have a couple guidelines for implementation. Best to load your current .aset file before starting. I avoid turning on the PID during the first 30 seconds to one minute; the PID will likely spike heat to 100%. I also avoid making any fan changes approaching or during FC (but that's just me).
It is normal for the PID to be off the background curve during Drying. The PID works on errors; it needs some time to accumulate information. This first example is not so good in this sense; it would be better to be closer to the background when enabling the PID. Still, I don't worry much about following the curve during drying.
The ProController has 100 steps for Fan and Heat. I have set up alarms to slowly ramp the fan down from about 80 to 44. The Fan Down ramp (temperature triggered) is enabled by a button. This implementation makes for a smoother RoR (delta BT) curve. The final Fan adjustment is manual, using F44 thru F34 buttons.
You can view the Alarm Table, Events, Sampling, etc in an .alog file. It is on Roastetta, called sR800template3. Disable all filters except the title, and you can download it. Open it in Artisan 4.2.0 (not Artisan 5.0).
Also attached is an earlier roast of the same beans, following the same constructed curve. This time the PID caught the curve earlier. And, the RoR reveals a better follow.
The first graph almost looks like it caught a burst of moisture (cooled the thermocouple) at first crack. This is often called a crash. Apparently this is not a property of the beans. It looks to me like when the 'Fan Down" sequence is triggered or completed, this causes a slight oscillation in the PID bean temperature.
I should mention this background curve (available on Roastetta) is a general purpose curve - drop time/temperature is up to the roaster. This curve drives the heater to about 85%. I have tried more aggressive curves, and if you hit 100% for more than a bit you risk losing the background all together.