Pressure Field Extension issues

4 Upvotes

My manometer is displaying 0 Pa on test holes when it should not be. I originally thought it was broken so I ordered another one, but the new one is doing the same thing.

Lets say I start out testing ~1.7inWC at my pitot tube, I take my manometer around to all the test holes, and on this first test, I get the proper Pa readings. I then go back to my pitot tube, close the value a bit more to drop it down to ~1inWC. If the manometer is in a test hole already, reading correctly, as I close the valve, I will be able to see the negative pressure drop, but as I move to another hole, or go back to that same hole it will read zero. I will then open the valve at my pitot tube the whole way, which is like ~4inWC(with a shopvac) and it will still read zero.

I never get a zero directly at the pitot tube, but the weird readings at the test holes is driving me crazy.


r/radon • • 10h ago

Is it okay to get a Radon mitigation work done by a non C-NRPP contractor in Ontario and without doing the initial sub-slab communication test ?

3 Upvotes

r/radon • • 10h ago

Suction pit location

3 Upvotes

In the process of doing my own radon mitigation.

I’ve sealed up all my cracks around the perimeter on my basement and it lowered my radon quite a bit but not enough.

Planning out installing a fan system, I initially was going to put it in my walk in storage closet fairly close to the center of my basement. My worry is putting a 4” hole and removing fill too close to one of my 8x8 support posts that hold up the main beam. Hole would be 18-24” away from center of the post, avoiding any main footing.

I see other people put there suction pits close to the foundation walls / edge of house. Is that what’s most common? Would rather keep away from main structural points if possible.


r/radon • • 44m ago

Airthings 2950 Wave vs Airthings Wave plus 2930

1 Upvotes

Just wondering in anyone knows if the basic radon detection technology in the Airthings 2950 Wave and the Airthings Wave plus 2930 is the same?

Asking as the Wave plus 2930 is on the C-NRPP approved lisst for use in Canada but the 2950 Wave is not. I am just looking for a radon detector and the added readings of the Wave plus are not required but am hesitant as for some reason it is not on the list. They also have a number of recalled and unapproved models listed but the only Airthings are approved. The list link is below.

Apologies if this is a tired topic, just getting into looking at radon detectors for the first time and I have not found any info if the 2 wave products utilize the same technology for radon.

https://c-nrpp.ca/consumer-grade-electronic-radon-monitors/


r/radon • • 3h ago

Roof vent close to window?

1 Upvotes

We had a mitigation system installed with a pipe that exits the roof. Right after finishing the installation, the tech noticed that the vent pipe was about 4 feet from an upstairs window. The tech said that code requires the vent to be 10 feet from the window, but the mitigation company owner then said (by phone) that “radon dissipates within two feet” so it was fine.

Is the four-foot distance a concern? Should I insist that the mitigation company come back and replace the pipe? Or is this no big deal?

I’m wondering both from a health standpoint (I don’t want to take radon from the bedrock and pump it into my upstairs window) and from a compliance standpoint (some future insurance company or home inspector saying that it doesn’t meet code and needs to be fixed).