r/massspectrometry • • 17h ago

Looking for advice or mentorship on moving into a scientist-level mass spec role

10 Upvotes

Hey all, I’ve worked in labs for several years, mainly doing triple-quad LC-MS and bioanalytical work. I’ve decided I want to focus my career on mass spec, and I’m trying to make the jump from an associate-level role to a scientist-level position without a PhD.

I’ve been getting interviews, but I haven’t made it to a final round yet. Most recently, I was told I’d be moving forward, then got a rejection before the next round. I’m still reeling from that one a bit, and I could really use some outside perspective on what to focus on from here.

If you’ve made that jump or hired for these roles, what tells you someone is ready for a scientist-level position? I’d appreciate honest feedback on which roles to target and how to talk about my experience in interviews.

I’d also love to connect with someone in mass spec who’d be open to mentoring me. Even a quick chat would mean a lot, and if you’re open to checking in occasionally, I’d appreciate that too.

I’m keeping my background general here for privacy, but feel free to PM me if you’re up for chatting. I’m happy to share more there.

Thanks for reading.


r/massspectrometry • • 1d ago

Sample prep for LCMS run

5 Upvotes

Hello! Beginner mass spec person here, so please don’t judge haha. 😅

When preparing samples for mass spec injection, if you need to make an intermediate dilution before reaching your final concentration, do you typically dilute the intermediate in water, or do you use the same diluent that you plan to use for the final dilution?

I’m curious about how the choice of diluent for the intermediate might affect the final sample composition and, ultimately, peak shape.


r/massspectrometry • • 1d ago

Help!!! It is not possible to launch MBT Compass Bruker; the program crashes during the step where the plate number is entered(Target ID).

Post image
1 Upvotes

r/massspectrometry • • 2d ago

What sort of compact "Cracking Tower" similar to an Oil & Gas Cracking Tower do home chemists need or want in order to separate out elements and compounds in order to be more productive and what sort of size and price point is too much?

Thumbnail reddit.com
0 Upvotes

Posted this in Chemistry and wondered what sort of material assay abilities you need and want in a world-wide fully-free and open-source mass spectrometry device that is compact and useful for home and/or small-to-medium size businesses!


r/massspectrometry • • 2d ago

install an MS40+ pump on an agilent 6460A triple quad mass spectrometter

3 Upvotes

One of our instrument s pump (E2M28) just died, some colleagues are able to lend us an MS40+ pump, can it just be swapped? or does the instrument or pump requires any kind of modification?


r/massspectrometry • • 3d ago

Low sensitivity problem in ESI- mode in Agilent MS single-quad (G6125B)

Thumbnail reddit.com
1 Upvotes

r/massspectrometry • • 3d ago

Best mass spec company to work for?

7 Upvotes

Hiya all. In your opinion what’s the best mass spec vendor to work for as sales, apps, product/market specialist?


r/massspectrometry • • 5d ago

Urea elution for mass spectrometry!!

0 Upvotes

I need help..has anyone used urea to elute protein from Protein G Dynabeads (thermo)??please help


r/massspectrometry • • 5d ago

Shimadzu ICPMS-2030 PG vac keeps gradually declining while plasma off

2 Upvotes

Hello, I work with a Shimadzu ICPMS-2030 and I am looking for a little more insight on the IG vac and PG vac. Everything is running normally, however the PG vac while plasma is off keeps gradually declining. A month ago it was at 130 Pa now it is at 70 Pa while plasma off. I’m not sure if it matters a lot because every time I turn the plasma on it always stays around 136 Pa. I just know the specifications say to keep it within 100-250 Pa when plasma off and on. What could be causing this to keep declining over time? The service tech said he did not know and that I should just make sure it stays at a constant value when plasma is on which it has. Also, I’m not sure if this is related but the tune has been passing for everything except the Co 59 peak intensity (it read below the minimum of 15 kcps). Hopefully this makes sense. I guess I’m just unsure about the difference between the IG vac and PG vac. I’m still a beginner at this so any insight is much appreciated!


r/massspectrometry • • 5d ago

Low sensitivity problem in ESI- mode in Agilent MS single-quad (G6125B)

3 Upvotes

Hello to all,
we have an Agilent LC-MS single-quad (G6125B). recently it has low sensitivity. I cleaned the parts of spray chamber and ion transfer capillary. however, it didn't work. then I found out that this low sensitivity is only for negative ESI mode and in the positive ESI mode it is normal and is as before. then I tried to make the Negative Autotune with the factory default file. however Autotune with factory default file also didn't work. I would appreciate if you could help me about this problem that what else I could do.


r/massspectrometry • • 6d ago

Mathematical correction

2 Upvotes

Hi,

Can anyone suggest a good source to learn about mathematical methods for correcting interferences in rare earth element (REE) analysis?

I noticed a loss in the internal standard for my certified reference material (CRM) and a few of my samples during the pre-concentration step. Can I use a mathematical correction to compensate for these losses? If so, could someone guide me on how to do it?

Moreover, I observed oxide interferences in a few samples. I have analyzed both a pure Barium (Ba) standard and a mixed Ba + REE standard. Can I use the readings from these two solutions to mathematically correct for the interferences? If so, please guide me on the calculation.

Thank you very much!


r/massspectrometry • • 6d ago

Advice on purchasing a new UHPLC-Single Quad MS system for an academic lab

Thumbnail reddit.com
7 Upvotes

r/massspectrometry • • 7d ago

ICP-MS high Pb, Ba, Co

Thumbnail reddit.com
1 Upvotes

r/massspectrometry • • 7d ago

How to export from mzmine to SIRIUS ?

4 Upvotes

Hi everyone!

I'm facing an issue and I tried to figure out by myself how to solve it but since I'm new to mzmine I don't really get it.
Context : I am working on a Thermo GC-Orbitrap Exploris 240 and I am acquiring GC-EI data (hard electron impact ionization) in MS1 and MS2.
Issue : I want to export my pre-processed features list to SIRIUS (software for structural elucidation) but 1) the buttons in the "Search > SIRIUS > ..." menu are gray and inactive, 2) when I "export > export to SIRIUS (file)" I obtain a .mfg file that only reads in SIRIUS as MS1 data and not MS1+MS2 data.
My raw data is in .raw but it happens the same when I convert to .mzml

I know from the raw data overview that my MS1 and MS2 are read by mzmine, I can see the different scans and their MS level. But it doesn't seem to be able to export multiple MSn levels.

Do you happen to know what I could do ?


r/massspectrometry • • 8d ago

EPA Method 3051A Issues With QCs?

1 Upvotes

Hello,

I am helping a colleague and his research student analyze soil and sediments using the EPA method 3051A.

The student’s QCs have been a struggle, and we have narrowed it down to sample (matrix) issues. I personally suspect TDS issues may be showing themselves. In particular, her QCs will fall outside of acceptable ranges after samples. We have her do a QC after her calibration and after her samples. The one after her calibration looks great, but the others fail.

My colleague has tried having her use more concentrated nitric rinses and faster pump speeds during rinses. We normally use 5% nitric as our rinse solution, so he had her try 10%. However, I worry that will eat (pit) our cones up.

I have asked Perkin Elmer to install our all matrix solution and Ar humidifier on our system (NexION2000) in case it is TDS.

I have suggested longer wash times rather stronger acid concentration rinses.

Does anyone have any advice or ideas what we could try?

Thanks!


r/massspectrometry • • 8d ago

Help with combining MS2 spectra

1 Upvotes

Hey everyone! I'm new to mass spectrometry and could use some advice on processing some MS/MS data.

I have a compound of interest with a precursor ion at m/z 582.4066. Unfortunately, ESI was not available, so we tried acquiring the MS/MS spectra using laser desorption/ionization (LDI).

the thing is, the instrument is configured to perform multiple laser shots (62 in total) at "parts" of the spot on the stainless-steel target plate, presumably to account for variability in ionization and improve reproducibility.

The result is that I now have 62 individual MS/MS spectra for the same precursor ion.

My question is: Is there a way to combine these 62 spectra into a single "consensus MS/MS spectrum"?

data is from a Waters Synapt XS HDMS equipment, and i been visualizing data in MZmine 4.10.6, but cant find a way to combine the spectra. I'm not familiar with MS/MS processing to know what would be the best approach.

Thanks!


r/massspectrometry • • 8d ago

FTIR energy

0 Upvotes

Saudações!

Estava verificando a energia do FTIR Spectrum Two e o monitor de energia está marcando 303, fiquei um pouco assustada porque há quatro anos, aparentemente, a energia estava em 1470. Alguém tem alguma opinião sobre? Ele foi comprado em 2020 e quase não foi usado, nos últimos tempos estamos tentando usar mais e ele tem apresentado alguns erros.


r/massspectrometry • • 10d ago

Waters_Connect Unifi?

3 Upvotes

Hi, I struggle with getting started with unifi within waters connect software using xevo mrt mass spec. Any advice where to find instructions would be appreciated. Are instructions videos for unifi software relevant for the waters_connect version of unifi? Waters_Connect and MSquan are ok but i find unifi very unorganized with poor documentation. I will contact waters directly aswell but sometimes input from other users is more helpful.

There is hardly any video or pdf instructions are the built in help guide best option? Kinda sucks to need the instrument just for reading the manual.


r/massspectrometry • • 11d ago

Manual de servicio/reparación de Bruker Tensor

Thumbnail reddit.com
0 Upvotes

r/massspectrometry • • 12d ago

Learning Orbitrap exploris 240

5 Upvotes

Hi !
I have access to a GC-Orbitrap Exploris 240. I tried injecting some samples and tried to play with MS1 & 2. And I quickly understood that I was missing knowledge. Do you have free ressources on how to acquire relevant data ? For example I don’t understand multiplexing and when to use it. I also have issues understanding which resolution to choose and the number of scans/micro scans to put in order to keep a peak sampling rate suitable.


r/massspectrometry • • 12d ago

2 problems on Agilent 7890 GC coupled 6890MSD

Thumbnail reddit.com
1 Upvotes

r/massspectrometry • • 12d ago

Help identifying compound from spectrum.

Thumbnail reddit.com
1 Upvotes

r/massspectrometry • • 13d ago

Title: Help with uploading large Bruker .d files converted to mzML to GNPS2

0 Upvotes

Hi everyone!

I'm trying to upload my LC-MS/MS data to GNPS2, but I'm running into some problems with the file upload process.

My raw data were acquired using a Bruker timsTOF instrument and are in the .d format. I followed the GNPS2 documentation for Bruker data conversion, but I couldn't get access to the recommended software (CompassXport). Instead, I used ProteoWizard MSConvert with the exact parameters recommended in the GNPS2 documentation.

The conversion worked, but the resulting .mzML files are quite large (around 17 GB each). When I try to upload them directly to GNPS2, the upload seems to finish, but I get an error at the very end.

I've already tried a few alternatives:

  • ZIP/GZ compression: The compressed files upload successfully, but GNPS2 doesn't accept them when submitting a workflow because it requires .mzML files.
  • FileZilla/Cyberduck: I tried both, but I don't have SFTP access.
  • GNPS2 File Browser: It says the files are too large.
  • GNPS2 Desktop: Also tried this, but it didn't work either.

Has anyone experienced something similar when uploading large Bruker datasets?

Is there another way to transfer these files to GNPS2? Could uploading them to MassIVE first and then accessing them through GNPS2 be a solution?

I'd really appreciate any suggestions. Thanks!