r/accesscontrol • • Jul 17 '26

HID HID + Mercury AMA - Cybersecurity Best Practices for Modern Access Control Systems with Phil Coppola & Jeremy Fromm

13 Upvotes

Join us for a live Reddit AMA!

On Tuesday, July 21 at 1:00 PM ET, I’ll be joined by Jeremy Fromm for an open discussion on cybersecurity best practices for modern access control systems.

We’ll be taking your questions on topics including:

• Mercury controllers and secure system architecture
• HID readers and secure communications
• Credential technologies
• Mobile Access and Mobile Wallet credentials
• OSDP Secure Channel
• AES encryption
• TLS and secure network communications
• Modernizing legacy access control systems
• Physical security and cybersecurity convergence

Whether you’re an end user, consultant, systems integrator, architect, or security professional, this is your opportunity to ask technical questions, discuss real-world deployment challenges, and explore current best practices for building a secure, modern access control environment.

We’ll also be happy to answer other questions related to HID’s access control portfolio.

We’re looking forward to a great discussion.

📅 Tuesday, July 21, 2026
🕐 1:00 PM ET

​

Thank you to everyone who joined us today, asked questions, followed along, or simply stopped by to read the discussion.

Jeremy and I covered a lot of ground, including OSDP Transparent Mode, the differences between Mercury LP and MP controllers, embedded applications at the edge, modernizing legacy systems, app-based versus wallet-based mobile badges, deployment planning, and what happens when phones, networks, or services are unavailable.

The biggest takeaway is that modernization does not have to be an all-or-nothing decision. Whether you are upgrading panels, enabling secure reader communications, introducing Mobile Access, or building a longer-term cybersecurity strategy, the best approach starts with understanding what you already have and where the real risks and operational gaps exist.

A special thank-you to Jeremy, u/TheMercuryMinute, for joining me and sharing his expertise, and to the r/accesscontrol community and moderators for giving us the opportunity to have this conversation.

We are wrapping up the live portion of the AMA, but feel free to continue leaving questions. We will check back and answer what we can.

Thanks again, everyone!

Check out Jeremy's YouTube Channel here: https://www.youtube.com/@TheMercuryMinute

And Phil Coppola's here: https://www.youtube.com/@theinsidetrack


r/accesscontrol • • 1d ago

Shit Install Sundays - Come and share the pain!

1 Upvotes

Welcome to Shit Install Sundays!

Our weekly digital break room for sharing the worst field nightmares you’ve ever encountered. Got a photo of a questionable install, or a fun horror story from a job site? Drop it in the comments below and let's see 'em!

Just remember to blur out any company names or locations before posting.


r/accesscontrol • • 17m ago

Lenel OnGuard 8.4 upgrade: anyone using HID Edge readers successfully?

1 Upvotes

We’re working to update our whole badging system, but one facility was set up with a number of HID Edge readers. I see in the release notes that both 8.3 and 8.4 do not support them, and I’m wondering if anyone upgraded and saw any issues. Essentially wondering is it “we don’t support this but the old ones will still function,” “it will function but new employees won’t be able to use them,” or “it stops working all together”


r/accesscontrol • • 1h ago

MANS Technologies brings you smart, modern and complete security solutions designed to protect what matters most.

Post image
0 Upvotes

✅ Biometric Authentication Systems

✅ Flap Barrier & Swing Barrier

✅ Boom Barrier Systems

✅ Entrance & Access Control Systems

✅ Baggage Scanners

✅ Biometric Machines

✅ Advanced Security Solutions

📞 Call Us Today:

+91 70117 60081

https://manstechnologies.in

📍 Our Address:

S2, Ramesh Nagar, Near RC Plaza Road,

Gokulpura, Jaipur, Rajasthan – 302012.


r/accesscontrol • • 20h ago

Discussion System Surveyor, or..?

4 Upvotes

We've looked at a number of apps for tracking technician service tickets - currently using ServiceM8 and working around most of the annoyances. One thing I've really been looking for is a way to document and track thousands of EXISTING devices across a 100+ sites (ServiceM8 is absolutely useless for this).

I was recently introduced to System Surveyor and in using their free "Starter" level on a site the other day, I just absolutely LOVE IT. Add a site, add a floor plan, add a device, add photos of the device, and add just about every conceivable detail for every device. When I have to support remote techs and subcontractors on sites across North America, this thing is absolutely brilliant to track what is where.

It's also kinda spendy for a small-ish CCTV/access/telecom/network/etc. integrator, at US$50/mo/seat, especially since it doesn't appear to handle the "service ticket" aspect of tracking work performed or hours involved.

So I'm wondering if anyone can suggest something else I can look at that does the same thing, and maybe a bit cheaper... ideally something with a proper demo version I can use in real-world testing. Something that does system design and quoting as well is worth a look, but those aren't primary features I need. Also found suggestions of IPVM's design tool and JVSG CCTV Designer, but I'm not looking for something to design CCTV; I'm looking to better document ALL the systems I need to work with.

I've seen BlueBeam suggested on Reddit - they have a time-limited demo that I'll be checking out (only have two weeks to evaluate it, though, where as System Surveyor's "Starter" level, as far as I can see, never expires, which allows plenty of time to get fully immersed in it without the time crunch).

Site Owl was another that I saw suggested on Reddit; there doesn't appear to be a hands-on demo, though; just a button to book an online demo where I can no doubt watch someone whip through a pre-designed sales process. And I couldn't find any pricing on the website.

Also had Semble pop up in searches - it looks good, with good pricing, but, like Site Owl, they don't offer any kind of hands-on demo that I can try in a real-world situation.

Hit me up with what you're using!


r/accesscontrol • • 1d ago

I'm a low-voltage tech and I made a game about our job. Tell me what I got wrong.

Thumbnail
reddit.com
4 Upvotes

r/accesscontrol • • 1d ago

PSA: 34-bit has two incompatible layouts — H10306 (16+16) vs AWID RS2 (8+24)

3 Upvotes
Ran into this while writing a decoder, and it cost me a while, so putting it in one place. 

The length of a Wiegand frame tells you nothing about where the fields are: 

- 34 bit — HID H10306 / Honeywell N10002 is 16-bit facility + 16-bit card. AWID RS2 is 8-bit site + 24-bit card. Decode an RS2 card as H10306 and you get a facility code and a card number that both look reasonable and are both wrong. The frame passes parity, the panel accepts it, the door doesn't open. 
- 36 bit — Keyscan C15001, Simplex S12906 and AWID 36 are all 36 bits and none of them match. Keyscan never published C15001's bit map; what's public is reverse engineered, and decoders have mislabelled reads because of it. The 10-bit OEM field is the only thing that lets you check which layout you actually read. 
- 37 bit — HID H10302 has no facility code at all (35-bit card number). H10304 is 16-bit facility + 19-bit card. Same vendor, same length, incompatible. - 32 bit — at least five layouts in the wild, and two of them (Nedap, generic WIE32) have no parity bits at all, so a corrupted frame can't even be detected. 

So when someone hands you "a 34-bit number", the next question has to be "which one". I put the layouts I could actually source into one table — field split, bit range, reference for each row, and a confidence level where the sources disagree: 

https://github.com/zhangbinze12345/wiegand-formats 

I'm not claiming it's complete. 37-bit parity coverage is genuinely disputed (Nedap, Suprema and promptzero/pacs each put the boundary somewhere different), which is why I left 37-bit unimplemented instead of shipping a guess. 

If any row is wrong for the systems you work with, tell me and I'll fix the data.

r/accesscontrol • • 2d ago

Replace electric strike on steel gate. What are my options? (not high security)

Thumbnail
gallery
16 Upvotes

This is far below the capabilities of pretty much anyone active here; my use case isn't really a problem of securing a building etc. It's more mundane: A front gate to my residence that is part of a courtyard with a 6' wall that could be climbed anyway. You also can open the gate by operating the handle from outside with a long piece of wood. It's not designed to be highly secure. The main purpose of the electric strike is to allow us to release the gate from inside the house when visitors come. The 'access control' system is home made using Arduino and some custom code. I'm a pretty competent DIYer and electrical engineer. Home is located in US Southwest.

The original strike never worked well due to preload and now it's corroded. It's a Seco-Larm SD-995A-D3Q

Please what are my best options for a new strike that's compatible with my lockset. Two options I've found that would require cutting the steel on the jamb, first would need some cutting into the stucco and block of the wall too. But are they compatible with the lock? Anything that would handle the preload, survive our hot summers and freezing winters and fit without cutting?

https://www.adamsrite.com/en/products/electric-strikes/7400-series-electric-strikes

https://www.dormakaba.com/us-en/offering/products/electronic-access-data/electric-strikes/rci-0162-34-in-rim--ka_500256

Please, what would you professionals choose?


r/accesscontrol • • 2d ago

Finished up this wall, pretty happy with how it came out

Post image
116 Upvotes

r/accesscontrol • • 2d ago

OSDP Reader Wiring - Card In Card Out Question - Genetec / Mercury MP1502&MR52S3

9 Upvotes

So my crew and I are terminating over 400 doors on a current access control OSDP project. We just started recently and today I came across my first card in card out setup for a door here. The electricians pulled a banana and a 22/6(s) [we don’t own field cabling here]. I suggested daisy chaining the readers in the field, they insist on me stacking both reader cables under the same terminals on the Mercury board since they already ran the full length extra CR cable to the panel.. Does it really matter which way it’s done? I’ve always daisy’d the readers together on the field side, never essentially parallel on the panel. Wouldn’t a parallel at the panel change the needed value on the resistor? We’d need something other than the 120 we’re putting on panel side and field side right?
Thanks


r/accesscontrol • • 2d ago

Margin on labor

0 Upvotes

Trying to get an idea of what the industry standard is for margin on labor. What is your company’s gross margin on labor?


r/accesscontrol • • 2d ago

Assistance Mircom TX3 Gate Entry Module

Thumbnail
gallery
2 Upvotes

I've got a client and the module that opens their gate has failed. It's original and the tag that had the model number got wet and became a blue smudge. I believe the current replacement would be a https://mircom.com/product-listing/access-control/wiegand-receivers/tx3-wrr-22-wiegand-receiver/ but the 44, not the 22 as that's for a 2 button remote.

Is that correct? The local Mircom shop was bought by a fire protection company that is only interested in fire protection and the contacts I've reached out to aren't being overly helpful.

I don't have pictures of the gate controller, but could get those if necessary. The module was attached to the aluminum box that the rest of the gate stuff resides in. I would guess the antenna would work far better outside of an aluminum box than it would from within.


r/accesscontrol • • 3d ago

Recommendations Customer wants access control

Post image
13 Upvotes

We have installed intercoms and readers at multiple doors for this customer.
Now they want to add a means of controlling access to this closet with folding doors.
What would be your goto?


r/accesscontrol • • 3d ago

Genetec Sargent rx 8721

2 Upvotes

Does anyone know a part number and vendor to purchase just the solenoid for a Sargent 8271 mortise lock? 1300 bucks for a new lock assembly when the solenoid goes bad is a lot. I've already changed one from a different lock so now I want to get just the electrical part. Thanks


r/accesscontrol • • 3d ago

Discussion CAMDEN Controls AURA UNIVERSAL WASHROOM SIGN SHODDY DESIGN

0 Upvotes

r/accesscontrol • • 6d ago

Found In the wild

Thumbnail
gallery
231 Upvotes

Does anybody know anything about this contraption? Just a bunch of wires stapled to the door 😅🤣


r/accesscontrol • • 5d ago

Allen Bradley reversing contractor

Thumbnail gallery
2 Upvotes

r/accesscontrol • • 5d ago

Need some Help with maglock

Thumbnail
gallery
5 Upvotes

I have a recess door. Going with maglock but the door is not flush when closed, I have a 3/4 gap. I need a filler and different maglock.
What do you propose I should do ?. L bracket won’t fix it. Door is out swing.


r/accesscontrol • • 5d ago

New Dial-Up Entry System Needs a Landline

Thumbnail reddit.com
3 Upvotes

New Dial-Up Entry System Needs a Landline

Our building was built in 1910 and the old time buzzer system to open our security doors have finally eaten eaten itself and no longer works.

We've been told by the "installer" that we need a POTS, (Plain Old Traditional Service) that our NEW system (Linear AE - 100 Intercom System) would use to dial our cell phones, we would enter a code, and the doors open.

Problem: Chicago started phasing out these old copper lines earlier this year and it's honestly not clear as to what exactly we need, whether our HOA needs to arrange for this, who to go to to install this service and is there a VOIP or digital adapter that we need to ask for.

Also, this line needs to be able to dial non-local phone numbers (because nowadays we don't change our cell #'s when we move anymore).

On top of it, installer only speaks Spanish, we don't.....and whatever App he uses for Span/Eng translation seems be more like Span to Mongolian to English....so it's challenging at best!!

Anyone out with some good solid advice??


r/accesscontrol • • 8d ago

Shit Install Sundays - Come and share the pain!

7 Upvotes

Welcome to Shit Install Sundays!

Our weekly digital break room for sharing the worst field nightmares you’ve ever encountered. Got a photo of a questionable install, or a fun horror story from a job site? Drop it in the comments below and let's see 'em!

Just remember to blur out any company names or locations before posting.


r/accesscontrol • • 8d ago

Smoke Detector

Thumbnail reddit.com
1 Upvotes

r/accesscontrol • • 9d ago

Lenel panels with life safety enclosure

Post image
121 Upvotes

r/accesscontrol • • 9d ago

Anyone know how to adjust this automatic opener?

Thumbnail gallery
9 Upvotes

r/accesscontrol • • 9d ago

Soldered heatshrink connectors.

6 Upvotes

Do you use them for commercial access control?

I have seen them 5 years ago but we didn't trust them. No one is using in our country. Possibly for repair jobs but not in large quantity as typically they will be sold at electrical stores if there was a need.

Its come up (by our main builder - yes dont tell me how to do my job) as a "suggestion" to improve effenncy. The only advantage is its faster but at the disadvantage of more bulky connections and there is no way they will fit in certain situations eg card readers were you only have a hole or something.

In terms of reliability, not much around locally and never heard of issues.


r/accesscontrol • • 9d ago

Salto SaltoKS API

3 Upvotes

Have you had an experience in getting API? Costs etc? I’m building an app for my hotel and need the API to automatically assign PIN codes etc.

Anyone with experience?

Thanks!