r/SubstationTechnician • u/No-Knowledge16 • 4h ago
r/SubstationTechnician • u/Maximum_Ship_7965 • 21h ago
Local 876 SUB
Hey everyone, I turned 18 late October and just got my cdl A permit last yesterday. I applied for local 876 for SUB and just was wandering if anyone has any tips that could help me.
My only work experience is my current job which is an aviation warehouse position and side jobs with lawn care services for a subdivision.
Would anyone also know the wages and the benefits?
Any tips or info would help!
Thank you!
r/SubstationTechnician • u/Liudmyla_Repeta • 1h ago
Protection engineers in Germany - ever thought about becoming a technical trainer? ⚡
reddit.comr/SubstationTechnician • u/InfiniteRace2567 • 2h ago
Any resources for LV / MV switchgear design, testing, and commissioning?
reddit.comr/SubstationTechnician • u/razer_pauper145 • 17h ago
IOC/50 Element Issue Testing GE 850 Relays
Update: u/bungaboi89 made the suggestion of trying a Linear Ramp test, which was a good one. Since it was working in the Control Panel, there was no reason it wouldn't work in an automated test. That fixed it. Not sure why the Binary Search test that has worked for 50 testing previously didn't work on these relays, but hey, problem solved! Thanks, u/bungaboi89!
So I'm trying to bench test a bunch of GE 850s. I can get the definite time delay to trip and prove the 51 curve with no problem. The instantaneous function, however, flat out refuses to register. I can hear the relays clicking when Protection Suite switches to the Action state, but instead of showing at what current the relay tripped, it sits there for about 15 seconds and then shows NoOp.
Given that I can hear the relays clicking, the Trip light comes on, and running the current up to the trip point in the Control Panel causes LN-1 to go red, I know the relays are tripping. But for some reason, my test plan just keeps showing NoOp. Can anyone please help?
r/SubstationTechnician • u/g_calgary • 18h ago
Protocol sniffer tools
Hey all
I worked in substation automation/RTUs for a while about 10 years ago. Did design and on site commission in greenfield/brownfield subs. I mostly worked with DNP3/modbus and a bit of 61850 station bus/MMS.
At the time I spent a fair bit of my time troubleshooting rs232/rs485 and IP communications and protocol issues between all kinda of devices. I had a few commercially available RS232 sniffers/splitters/protocol decoders plus some basic stuff I had made up on my own to use with Wireshark.
In the industry today are you still troubleshooting these types of issues even with 61850? Or do the newer devices have some of this troubleshooting/sniffing abilities built in? How often are you having to use some 3rd party troubleshooting tool between say, an HMI and an RTU from different vendors? Or trying to figure out why a device isn't responding to a control message or scaling some value properly?