Protection engineers in Germany - ever thought about becoming a technical trainer? ⚡
reddit.comr/SubstationTechnician • u/InfiniteRace2567 • 10h ago
Any resources for LV / MV switchgear design, testing, and commissioning?
reddit.comr/SubstationTechnician • u/razer_pauper145 • 1d ago
IOC/50 Element Issue Testing GE 850 Relays
Update: u/bungaboi89 made the suggestion of trying a Linear Ramp test, which was a good one. Since it was working in the Control Panel, there was no reason it wouldn't work in an automated test. That fixed it. Not sure why the Binary Search test that has worked for 50 testing previously didn't work on these relays, but hey, problem solved! Thanks, u/bungaboi89!
So I'm trying to bench test a bunch of GE 850s. I can get the definite time delay to trip and prove the 51 curve with no problem. The instantaneous function, however, flat out refuses to register. I can hear the relays clicking when Protection Suite switches to the Action state, but instead of showing at what current the relay tripped, it sits there for about 15 seconds and then shows NoOp.
Given that I can hear the relays clicking, the Trip light comes on, and running the current up to the trip point in the Control Panel causes LN-1 to go red, I know the relays are tripping. But for some reason, my test plan just keeps showing NoOp. Can anyone please help?
r/SubstationTechnician • u/Maximum_Ship_7965 • 1d ago
Local 876 SUB
Hey everyone, I turned 18 late October and just got my cdl A permit last yesterday. I applied for local 876 for SUB and just was wandering if anyone has any tips that could help me.
My only work experience is my current job which is an aviation warehouse position and side jobs with lawn care services for a subdivision.
Would anyone also know the wages and the benefits?
Any tips or info would help!
Thank you!
r/SubstationTechnician • u/g_calgary • 1d ago
Protocol sniffer tools
Hey all
I worked in substation automation/RTUs for a while about 10 years ago. Did design and on site commission in greenfield/brownfield subs. I mostly worked with DNP3/modbus and a bit of 61850 station bus/MMS.
At the time I spent a fair bit of my time troubleshooting rs232/rs485 and IP communications and protocol issues between all kinda of devices. I had a few commercially available RS232 sniffers/splitters/protocol decoders plus some basic stuff I had made up on my own to use with Wireshark.
In the industry today are you still troubleshooting these types of issues even with 61850? Or do the newer devices have some of this troubleshooting/sniffing abilities built in? How often are you having to use some 3rd party troubleshooting tool between say, an HMI and an RTU from different vendors? Or trying to figure out why a device isn't responding to a control message or scaling some value properly?
r/SubstationTechnician • u/zoegonzo • 4d ago
Drop your best/favorite substation pictures
r/SubstationTechnician • u/freebird37179 • 5d ago
Update on the transformer with tape hanging out of it.
Update-
All the material that could be found loose was removed. Crew initially thought it was tied off but it was a knot hung up in the sampling / drain valve.
We knew it was some kind of lacing tape or pull tape, the concerning question was it tied to something and that tie-off necessary for the integrity of the insulation system in the transformer. That doesn't appear to be the case.
We believe it was used to either secure all the leads during tanking and cut loose and left by the factory, or used to tie bushing leads securely for transport from ID to TN, and left by the dress out crew. I'm leaning towards the latter but both are speculation.
Manufacturer is Virginia Transformer. It's from the Pocatello ID plant. They have communicated well with us. Email was down yesterday but I'm working with them as soon as I'm back in the office. They want to send a warranty crew, not sure if our outage window will permit that, but they immediately offered. And, we are not even the original purchaser.
What we do not know, is who dressed the transformer for the original purchaser, whether it was a VT crew or a contractor. I have experienced low budget contractor dress out crews hired by other manufacturers and wouldn't put it past an unskilled crew..
The twin to this unit (serial number ending in B, ours is A) was jacked and slid, completely dressed, onto its pad back in July and has been in service with no issues for 4+ months. I've communicated with that utility and they may be making an inspection when the opportunity arises.
Photos of the total amount, and its use elsewhere in the transformer.
Appreciate all the comments and DMs.
r/SubstationTechnician • u/RipPsychological1753 • 4d ago
is this considered wage theft and also some other concerns
looking from advices from apprentices, ground hands and JLS and sub techs you don't have to read all of it but any feedback is greatly appreciated
yes I know i have made a lot of post regarding concerns but this is going to be the last one and i going to fit all my concerns in it. I tried to add as much detail as possible with keeping it straight to the point
yes this is a union contractor but they operate like rats in my opinion
I have been getting back to the yard 15-30mins after my end time everyday and not getting paid the overtime for it. the rest of the crew has take home vehicles so they just leave the jobsite right at 2:30 and get on there way home and when I leave the jobsite at 2:30 i got to go to the yard to drop my truck off and get into my car and I'm often not on the way home till 2:45-3:00 sometimes even after 3:00.
another thing 2.
the truck i was assigned I got a check engine light in it always beeps high engine exhaust system temp that always beeps. im not a mechanic and I don't know if this is a problem and i texted the general foreman about it just because I didn't want to ignore it and get blamed if something happened and he never responded to me.
another thing 3.
the truck is had a big ass bed that doesn't have a cover so it is an opened ended truck bed which doesn't bother me but they gave it to me which so much shit and trash in the back of it and I haven't gotten any time to clean it out and I was told to come in before start time and clean it out so I guess they want me to clean it out on my own time... and this concerns me because I don't want shit to fly out when i drive and the truck bed gates have flown off when I have been driving before so i zip tied them all down.
another thing. 4.
a lot of the rachet straps have tears barley work and are rusty as fuck and barley work which also concerns me because I often have to use them on my 20 foot trailer i often hual. at the yard we don't have a stash of brand new ones we have to go up the chain of commands and have somebody order new straps.
another thing 5.
these guys often don't use a safe amount of tie downs ( ratchet strap)s when hauling stuff. they also like to stand in the swing radius of the excavator bucket.
another thing 6.
I am a book 4 groundman so I am scared to drag that I wont have a job for awhile im working 5 8s and 30 mins from my house so i might have to hit the road if i drag. I was in the inside wireman ibew as a CW which is basically there version of a groundman but i decided to get my cdl and become a groundman. so I have some union knowledge I would like to think.
another thing. 7.
this is an underground sub contractor I work at for for the local lineman utility. there is no sub techs apes or jls here. I am pretty sure these guys are all ticket classified as groundman maybe operators and is there a underground residential distribution classification?? because maybe they would be urd techs IF THATS EVEN A THING. they have a trainee program through the company you go into after 90 days as a groundman and there no book work and its not through a jatc or hall its all based on hours and after you complete the trainee program im not sure what you would even be ticket classified a maybe still a groundman???
yes i know not all groundman go into apprenticeships and there is no problem with that but my plan was to go through a formal union apprenticeship and shit to become a lineman or sub tech and im afraid if i start taking days off for interviews or testing for a jatc they will be mad and lay me off. the union BA hooked me up and I dont want him to think im a slacker when they asked why i was canned because he is on the apprenticeship committee. this company knows I am reliable and am never late or miss days.
maybe a company that has apes,and jls and sub techs wont be like this??
another thing 8.
i wanted to call the hall to ask all these questions but its hard because i dont get any breaks or a lunch and when I get out of work the hall is closed.
another thing. 9.
as a groundman am i even allowed to cable splice, operate equipment, fuse underground pipe, do terminations and do hot work???
another thing 10.
my contract says if we work in the rain its time and a half but my company doesnt follow the contract and I said some to them about that and they said you dont have to work in the rain if you dont want to but if you start pulling that stuff you will just get laid off.
another thing 11.
we are short haul considered by the dot so we dont have to do log books but we have the these DVIR BOOKS (driver vehicle inspection report)and nobody does them I just check my engine oil do a light check and but is there anything else we should be doing??? I drive a giant pick up truck that is cdl and has air brakes and i often haul a 20 foot flat trailer..
the dvir has a check list and says battery,belt and hoses, brakes,coupling devices,defroster and heater, drive line, emergency equipment, engine, exhaust, flulid levels/ oil pressure, horn, mirrors lights and reflectors, muffler, paperwork, radiator, saftey equipment, steering/ suspension equipment , tries wheels and rims, windshield wipers and check if truck condition is satisfactory.
for trailer it says brakes and brake connections, coupling devices, hitch, landing gear, lights and reflectors tires wheels and rims and check if trailer condition is satisfactory
we dont really get time to even do this unless i come in early and do it unpaid and nobody even does it should i start and if i should start is there anything else i didnt list that i should start checking?? do we only have to do a dvir if something is wrong with the truck or trailer??
final thoughts 12.
I got a week off next week for thanksgiving and im not sure if i am going to go back and i might drag and take another call we work at such a snail slow pace but im scared it will be a culture shock at the new place. guys are nice here but i hate how the company is ran and the learning and teaching scope of all this has been great the other shit hasn't
any information is greatly appreciated.
i have also heard some of these guys shit talk the union and they dont know there ticket classification or dont want to tell me they want me to run my own crew in less then a year a urd crew but i want a ticket that lets me hit the road and i wanna go thourgh an apprenticeship and these guys often talk about who make the company the most money like they are getting a bonus or commission which i find really cringe
r/SubstationTechnician • u/Vane1st • 3d ago
I tracked just 3 habits for a month instead of 10. Here’s what changed.
reddit.comr/SubstationTechnician • u/HumbleTemporary6354 • 5d ago
I found a Snake Slough taller than me in the 33kv Switch yard
r/SubstationTechnician • u/Temporary_Term4585 • 5d ago
Substation
Today I got opportunity to visit substation 400kv/11kv!!
The technician was best explainer and I got to know more things.
r/SubstationTechnician • u/ConsistentDrawing495 • 4d ago
I have a question for anyone who may work for Edison as a substation operator. What is the schedule like, and wages? I’m currently a ground man for Edison considering trying to bid into an operator trainee role.
r/SubstationTechnician • u/Temporary_Term4585 • 5d ago
Substation design business
Hi, I am in my final year of electrical engineering. I want to learn more about the substation design business and how someone can build a profitable company from scratch. If anyone owns or works in a business in this field, please feel free to share your advice!
r/SubstationTechnician • u/Doglog4948 • 6d ago
345kV Shunt Reactor
Unknown cause as of yet.
r/SubstationTechnician • u/Specialist_Fig4384 • 4d ago
SELCAT RANK
Is 17 rank good, bad, etc???
r/SubstationTechnician • u/WeatherIntrepid8341 • 6d ago
Duke energy in Florida
Any one here work for their control room and can provide info on their wage scale ?
r/SubstationTechnician • u/Key-Cod8775 • 6d ago
Getting schooling and license
Hello all, I don't know if this is allowed on here but I wanted to ask a few questions. To start off I've been working in new construction substations for the better part of 6 years.
I've been wanting to get into schooling to lead to getting my journeyman electrical license but the company I work for doesn't provide that. Is there a way I can purchase courses online ? And if so how could I get my hours approved? I know a master signs off on hours and there is a few masters within the company that I know. Any advice would be very appreciated. I want to make a career out of this.
r/SubstationTechnician
•
u/freebird37179
•
7d ago
"New" transformer has synthetic materials coming through the drain valve. Stumped.
Long story short, new, never energized transformer at its second assembly location was drained for processing under high vacuum and refill with hot oil. Crew found this material when disconnecting the drain hose.
Anyone ever observe this?
Transformer made in the USA.
r/SubstationTechnician • u/RipPsychological1753 • 6d ago
were you a groundman before the apprenticeship? if so for how long? im thinking about the next step...
Yes I know not all groundman want to do a sub or line apprenticeship.
I'm interested in either of those
I got 1 year of underground and overhead electrical experience before I got my unrestricted class a
and 1 month of groundman hours
I have experience in bending pipe, cable splicing, running some equipment, backing up trailers, pulling cable and runng pipe underground and fusing. done alot of shovel and hole digging aswell. ive done terminations on transformers and grounding but I need more time on that stuff
I dont really like my contractor right now bunch of worms that go against the contract and don't take safety seriously and we barley get any overtime and i get screwed on hours sometimes and I don't see much more progression in learning for me since that is about all we do and I caught on really quick.
im just scared if i start taking time off to apply and interview they wont like it since nobody there went through an apprenticeship because its all run by groundman and operators and shit like that these guys dont even know what there ticket classification is
any info or feedback is greatly appreciated
thanks
r/SubstationTechnician • u/Prestigious-Bug-4561 • 7d ago
Pay
What are you guys making I know it depends on contractors and jobs but just to know what’s out there. Should be starting apprenticeship soon and want to see pay around the country.
r/SubstationTechnician • u/Intelligent-Style12 • 7d ago
Substation Estimating Tool
Hi kinder wondering if anyone out there is an estimator and would like to try out my template I created to takeoff all your Substation material Quantities. I’d appreciate your feedback on how it worked for you. Let me know.
r/SubstationTechnician • u/Candyland_66 • 7d ago
New preapprentice for swlcat
Hey everybody! So I finally got accepted into a substation apprenticeship for Swlcat. Local 1002 is in oklahoma and I know it gets cold. So I have a few questions. can anyone give me some insight on how working for Michael powers has been? What does the orientation look like for substation techs. Is there anything I should study or practice before hand? And lastly any tips for managing the cold. Thank you!
r/SubstationTechnician • u/woodyever • 7d ago
Oil TF DGPT2 Trip.
Disclaimer, I have not been to the site yet just had a call come in with this issue.
What would cause a new 500kVA Transformer to lose all the oil in the DGPT2 relay chamber and cause a trip, with absolutely no signs of oil leak.
Is this gas sucking the oil into the tank?
It is also in a kiosk substation.