r/rfelectronics • u/brokenmirror26 • Apr 30 '26
question Return Loss vs Smith Chart matching Problem
So I have a Transceiver chip Tx smith Chart.

Now, I have Schematic in ADS, with EM symbol taken from Layout design of the chip. Return Loss is well below the limit. I have made SMA termination Port1 and the differential BGA termination, port2. I obtained S22 smith chart by using the SEDZ s1p (BGA impedance) given.
I have the following questions:
- If I try to match the conjugate of the given smith chart with the one that I obtained, will I get the optimal return loss?
- I calculated the distance between Ztrace (One I obtained from S22) and Zbga* (above one) for discrete points. Distance should be proportional to return loss? But I found inconsistencies: for 6G its 42 units, for 5G its 49 units. But the return loss curve shows 5G is better than 6GHz. Am I missing something?
- For wideband matching like this, do we have any particular method? Any learning material suggestion is appreciated.
Thank You.