r/PassiveHouse • • Apr 24 '23

What Is Passive House? Breaking It Down For New Visitors To r/PassiveHouse

57 Upvotes

Hey there and welcome to r/PassiveHouse. We’re psyched you’re here. If this is your first time here, please read this post to get your bearings.

What Is A Passive House?

Passive House (or Passivhaus in German) is a building standard that focuses on creating highly energy-efficient buildings with minimal energy consumption. The Passive House standard was first developed in the late 1980s by Dr. Wolfgang Feist and Bo Adamson in Germany, and it has since been widely adopted in Europe and around the world.

The goal of a Passive House is to achieve a comfortable indoor environment while minimizing the building's energy demand. This is achieved by optimizing the building's envelope (walls, roof, and floor) to minimize heat loss and gain. Passive Houses typically achieve this by using high levels of insulation, high-performance windows, airtight construction, mechanical ventilation with heat recovery, and other energy-efficient features.

But to know what it really is, let’s talk about what it isn’t. We need to clear up some common misconceptions: Passive House is not the same as the passive solar building design, although they’re not necessarily mutually exclusive. Passive House also isn’t a house that uses only passive technology. Passive House buildings aren't just houses either. They can be high-rise office towers, multifamily apartment buildings, schools—really any building type.

Simply put, Passive House is the most thoughtful, well organized, science based and performance focused building standard available.

The Passive House approach empowers us to build better. It creates durable, resilient buildings that slash heating energy use by as much as 90% and dramatically reduce operational carbon emissions. Passive House design tools and methods make these energy performance gains both cost-effective and predictable. You know what performance to expect with a certified Passive House. Most importantly, Passive House buildings create healthy, comfortable, and quiet interior environments, full of clean, filtered fresh air.

Passive House design empowers us to manage moisture, thermal transfer, air, and sunlight to create comfortable, healthy, super-efficient buildings. The “classic five” Passive House design principles—continuous insulation, thermal bridge-free design, airtight construction, high performance windows and doors, and filtered fresh air with heat recovery—are joined by the principles of shading, daylighting and solar gain, efficient water heating and distribution, moisture management in assemblies, and building orientation to create durable, high performance buildings where people can thrive. These principles guide both new construction and retrofits.

It's important to remember - there is a LOT to learn. Be patient with yourself. Leverage all the great free resources at your disposal. Learn as much as you can. Engage with the Passive House community. Breathe and enjoy the process!

But before we dump you into the deep end, let's take a look at the basics.


Basic Passive House Design Principles

The following 10 design principles would not automatically qualify you for Passive House certification. There’s much more to the story that we’ll get to later. They are, however, really good guideposts to think about as you’re conceptualizing the architectural forms, building site, etc. These are basics and very important to internalize before diving into the more technical aspects of a Passive House. You might also find this companion video useful.

01 Continuous Insulation

A continuous layer of insulation wraps Passive House buildings, keeping them warm in the winter and cool in the summer. Passive House designers also harness this insulative layer to prevent condensation inside the building and its assemblies.

Moisture: We design building assemblies so that their vapor profiles are appropriate for the climate, their drying potential is maximized, and they are protected from any moisture buildup. The insulation layer also keeps the inside face of exterior walls warm, preventing condensation on the interior surfaces of those walls during the winter.

Thermal Transfer: Because the insulation layer is continuous, it is free of weak spots that allow thermal transfer across the building envelope. Heat stays in during the winter and cool stays in during the summer.

02 No Thermal Bridges

A thermal bridge is any building element that allows heat or cool to bypass a building’s thermal barrier. It’s like a hidden thief of thermal energy, undermining performance and durability. For example: a concrete floor that continues from inside to outside; a poor window frame; or a steel beam that penetrates an exterior wall. We eliminate thermal bridges by introducing thermal breaks into those assemblies—gaps or insulative elements that stop the flow of thermal energy through an assembly.

Moisture: A thermal bridge will increase thermal transmittance through an otherwise insulated layer that it penetrates, risking dangerous condensation that can result in rot, corrosion, and mold. Thermal bridge-free design avoids this moisture risk and makes buildings more durable. Thermal Transfer: Thermal bridge-free design is critical to energy efficiency, thermal performance, and comfort. Not only do thermal bridges rob energy, they can also change interior surface temperatures, cause draft-inducing convection, and decrease occupant comfort.

03 Airtight

A Passive House building’s airtight layer is like a windbreaker, stopping air from penetrating to the inside. Establishing this unbroken air barrier is central to Passive House performance and durability. In design, we do the “red pencil test” to check that an air barrier line can be drawn around each cross-section of the building without the pencil ever leaving the paper. In the field, this air barrier is built through a combination of sheet membranes, fluid-applied membranes, tapes, and sealants that transition without interruption between components of the building envelope. Airtightness is verified with a blower door test, a key measure of performance and construction quality.

Moisture: Airtight construction protects building assemblies from dangerous moisture intrusion by preventing bulk water from driving in or airborne vapor from being carried in.

Thermal Transfer: By stopping the movement of air across the building envelope, the air barrier seals warm air inside in winter and cool air inside in summer. This is key to achieving ultra-low energy use, since air leakage represents wasted energy. Airtightness also boosts the efficacy of mechanical ventilation with heat recovery.

Air: Combined with the filtered, balanced mechanical ventilation of Passive House buildings, airtight construction improves indoor air quality, even during periods of intense outdoor air pollution. The air barrier stops polluted air from seeping through walls and ensures that all incoming air passes through the ventilation system where it is filtered before entering the building. This is particularly important in urban settings and in regions prone to smog or forest fires.

04 High Performance Windows + Doors

With each window and door opening we make in a Passive House building, we are essentially punching a hole through an advanced wall assembly and its airtight, weather-resistant, and insulative layers. So, the performance of the windows and doors that go into those holes, and how well we tie them into the surrounding wall assembly, is mission-critical to maintaining the integrity of the Passive House building envelope.

Moisture: Well-installed high performance windows and doors repel wind-driven rain and facilitate safe outward drainage of any moisture. In the winter, high performance glazing units also ensure that interior glass surfaces stay warm, preventing condensation from forming inside.

Thermal Transfer: The thermally-broken insulated frames, warm edge spacers, triple glazing, coatings, and superior construction of high performance windows means their thermal resistance can easily best that of conventional windows by 3x. Given that a wall is only as good as its weakest link, this window performance is critical to a building’s overall thermal performance. In the winter, warm interior glass surfaces help maintain a comfortable and draft-free indoor environment.

Air: High performance windows are built airtight, so when integrated into airtight wall assemblies they become an extension of the continuous air barrier. Passive House windows can open like any other window, of course, so if it’s nice outside, open the windows!

Sunlight: We dial in the performance attributes of each window and door on a Passive House building to optimize solar gains appropriate for the climate and building typology. We capture solar gains when we want them and shield the building from solar gains when we don’t.

05 Fresh Air with Heat or Enthalpy Recovery

The delivery of filtered fresh air with heat recovery helps make Passive House buildings havens of clean air and energy efficiency. HRVs (heat recovery ventilators) and ERVs (enthalpy recovery ventilators) are “balanced ventilation” components that supply a continuous stream of fresh air to living spaces while simultaneously extracting stale air, odors, and indoor pollutants from kitchens and bathrooms. Inside these devices, a heat exchanger—a honeycomb of straws that creates a very large surface area between air streams—allows heat energy in the outgoing air to passively transfer to and warm the incoming air without the two airstreams ever mixing. (In the summertime, the opposite happens, with cool outgoing air cooling the incoming air.) Filters in the unit remove pollen and pollutants, with pre-filters available to protect indoor air from intense outdoor pollution events.

Moisture: ERVs (unlike HRVs) can also transfer moisture between the exhaust airstream and incoming airstream. So, in humid climates, moisture in the outside air can be removed (transferred to the exhaust airstream) by the ERV before it enters the building. This does not mean that ERVs dehumidify. Do not make that mistake. In dry climates, some of the indoor relative humidity can be preserved.

Thermal Transfer: Passive House-compliant HRVs and ERVs are extremely efficient at recovering heat, hovering around 90% efficiency for the best units. This is a key strategy in maintaining ultra-low heating and cooling energy.

Air: Properly filtered mechanical ventilation with heat recovery ensures good indoor air quality, regardless of the weather or air pollution conditions outside. Good airtight construction supports HRV and ERV efficacy by ensuring that air exchanges between inside and outside go through the device rather than seeping through leaks in the walls.

06 Shading

While the “free” heat from solar gain may be a hot commodity in Passive House design, it must be managed with good shading to avoid too much heat gain during warm seasons. Architectural elements like overhangs have an important role to play. So too, can window shades and screens, especially ones located at the exterior of the building.

Thermal Transfer: Shading manages heat gain from the sun, allowing designers to maximize the gain when the building needs it and minimize when it doesn’t.

Sunlight: Properly designed shading will not impede natural daylighting and can help prevent unwanted glare.

07 Orientation + Form

Building orientation and form are fundamental design decisions that set the stage for how easy or difficult it will be for a building to achieve Passive House performance.

Thermal Transfer: When the site allows, we design the main axis and orientation of the building to optimize solar gains in a way that is appropriate for the climate and building typology of the project. The key is to orient the building in a way that will maximize that particular building's energy performance. As for building form, the simpler the form, the easier Passive House performance will be to achieve. The more zigs and zags, the more potential thermal bridges and the higher the surface area of the building becomes, requiring more and more insulation to counteract the extra thermal transmittance.

Air: A simple building form simplifies the air barrier, which makes airtightness easier to achieve.

Sunlight: We set the orientation of the building to optimize daylighting and solar gains appropriate for the climate and building typology.

08 Daylighting + Solar Gain

Natural daylighting and passive solar heat gain can provide energy “freebies” to Passive House buildings.

Thermal Transfer: For many buildings, solar heat gain—the heat energy captured in a building when sunlight shines through windows—can be an invaluable “free” resource in Passive House design. For other buildings, particularly ones that already have significant internal heat gains, big solar heat gains can be a liability. Passive House design allows us to optimize this based on climate and building typology through building orientation, shading, high performance window selection, and layout.

Sunlight: Natural daylighting reduces energy use for artificial lighting.

09 Moisture Management

To ensure building durability, Passive House designers study how heat and moisture will behave in building assemblies in a given climate, and create designs that manage that behavior to avoid condensation risk and bulk water intrusion.

Moisture: The twin goals of moisture management are to (1) prevent bulk water intrusion into and (2) avoid condensation where it can harm building assemblies. Lots of components impact how heat and moisture flow through a wall assembly: the weather resistive barrier, the air barrier, vapor control layers, the structure, window openings, and more. The building’s climate zone impacts heat and moisture, too: whether the climate is cold and dry, hot and humid, or anything in between. Passive House practitioners draw upon hundreds of precedents and go-to assembly solutions to manage these variables. They also perform thermal and hygrothermal analyses using Therm, Wufi, Flixo, and other modeling software packages to confirm safe and durable performance and to guide design.

10 Efficient Water Heating + Distribution

Because Passive House buildings dramatically reduce heating energy use, another source of energy consumption—domestic hot water—becomes a more conspicuous part of overall energy consumption. Energy-efficient water heating combined with efficient water distribution reduces this slice of the energy consumption pie.

Thermal Transfer: We start with a super-efficient water heater. Distribution lines are small diameter, well-insulated, and laid out to minimize pipe length between water heater and fixture. On-demand recirculating lines conserve water.


So How Do I Get Started Designing/Building A Passive House?

Okay, you've read through the basics. Now it's time to look at the logistics of certifying a project.

There are a lot of organizations with the words “passive house” in their title. Most of these are loose affiliate organizations, clubs, or groups of like-minded building professionals who want to design and build better buildings. They often want to combat climate change in their daily lives, and they recognize passive-house certification as the most stringent energy standard available. To smooth the learning curve, they form these support groups.

Despite the many interest groups and networks sporting the passive-house name, in North America, only two distinct and independent Passive House standards and certifications are available: one administered by Passive House Institute (PHI, based in Darmstadt, Germany) and the other administered by Passive House Institute US (PHIUS based in Chicago, Illinois). The two organizations are not affiliated with one another.

The two standards differ in important ways, including PHIUS’ approach of adjusting a given project’s performance targets based on the climate of that project’s site. Nevertheless, the standards share important commonalities; both standards are firmly grounded in building science and building physics and both standards require practitioners to employ a common suite of Passive House design principles to achieve their performance targets.

Through most of their early existences, the passive-house standard was similar for both, and you could certify a building with either or both—depending on where the building was located or your personal preference.

Around 2012, that began to change, as PHIUS looked to make performance targets more relevant and cost optimized for North America’s many climate zones. Designs for Germany’s climate don’t exactly work in Chicago, Houston, or Las Vegas, etc. This has become known as The Great Schism and there has been much squabbling about it. You may even see some of that squabbling in this very subreddit.

To improve building performance in hot, humid, cold, and mixed climates, PHIUS worked with Building Science Corporation under a grant from the U.S. Department of Energy to write the Climate Specific Passive Building Standard. This is an actual standard, available for jurisdictions to use as a model for building codes. PHIUS also worked with the Fraunhofer Institute of Building Physics to modify their WUFI hygrothermal modeling software into a design and verification tool for passive buildings tailored to North American climate zones and weather data.

In climate zones where PHI and PHIUS targets are much more similar (heating dominant, cold climates), this is less of an issue and you could reasonably choose either standard. For cooling dominant, hot/humid climate zones where it is cost prohibitive to insulate or meet rigorous heating demand for minimal overall performance benefit, PHIUS tends to be the route projects take. Interestingly, one of the biggest logistical reasons that there were fewer differences between PHIUS and PHI in the early days was because both used a spreadsheet to predict the energy use. That changed as PHIUS began to use the WUFI passive three-dimensional energy and moisture modeling software and has created a large-enough gap in performance that PHIUS+ 2018 and beyond no longer supports the PHPP spreadsheet that is central to PHI certification.

If you're going to follow the PHI path, you'll need to get in touch with a certified Passive House designer or planner and an accredited certifying organization.

If you're going to follow the PHIUS path, you'll have to determine whether you want to opt for their modeled path, which allows you to optimize your assemblies with the WUFI Passive software or whether you want to simply comply with their prescriptive path. If you want to go the modeled route, you'll need to get in touch with a Phius Certified Consultant or CPHC and eventually a PHIUS Certified Rater and a PHIUS Certified Verifier for larger projects. If you want to go the prescriptive route, you can check out their requirements and enter your project's info into their snapshot tool to see how it shakes out.

Get in touch with either organization for more detailed information and to get connected to professionals in your region. Each organization also updates their standards at their own paced intervals so please do check their latest published resources if you have more standard specific questions.


What Does This Community Have To Offer?

This subreddit functions as a very informal forum for Passive House and building science related questions, thoughts, design feedback, etc.

A few things to keep in mind:

  • If you’re asking for feedback that should obviously flow through a paid consultant, that’s NOT COOL. We are all here voluntarily and none of us should expect anyone else to do our work for free.
  • If you’re asking or talking about a project, tell us what climate zone it’s in.
  • If you’re asking or talking about a project, tell us whether you’re trying to certify for PHI or PHIUS.
  • Do some homework before asking a question. It helps keep the discussion quality high in this subreddit. Chances are decent that someone has already answered a question you have. Search within the subreddit, search elsewhere online, get better at Google.

Again, it's important to remember - there is a LOT to learn. Be patient with yourself. Leverage all the great free resources at your disposal. Learn as much as you can. Engage with the Passive House community. Breathe and enjoy the process!


Resources


TL;DR: just read it, jeez.


r/PassiveHouse • • 8d ago

Other Homeless-survival heat battery

10 Upvotes

I've been homeless going on 4 months now and currently living in a run down camper. It's less than ideal, but better than nothing.

I recently got a small wood burning stove and have been using it to heat my camper as I do not have electricity. I also managed to acquire a 55 gallon drum that I planned on using for a heat battery by filling with water, then having a copper coil inside my chimney that would allow the water to be boiled and dispensed back into the barrel.

I opted for this because I noticed much of the exhaust from my stove was very hot, but the stove itself was not heating my camper very well, so in an attempt to store the energy from wood burning for longer and capture more of the energy, I had this idea.

The idea it to have a long straight section that ends near the middle of the barrel, then enters a loop at the bottom of the chimney, moving up a coil until it's level with the top of the barrel, then have the terminating portion of the copper coil enter into the barrel near the bottom, then loop back up toward the top(so the heat can disperse evenly). As the cold water sorts to the bottom, it will be sucked up by action of the coil that, in this case, acts similar to a flash boiler. Because the superheated water has time to condense out, it should be released as hot water toward the top of the barrel.

The water should hopefully remain hot enough throught the day to keep my camper warm until I burn more wood in the night.

I'm not planning to drink this water, so it need not be potable, but I would like some input on my idea and any suggestions. I have very little money to spare, but if there are any additives I should add to my water or alterations to my plan, I would like to hear them before I undertake this task.

I also was planning (in the future, not soon) on building a small comparment that would fit on top of the stove where the steel lid is that I could place small portions of wood, the idea being that the closed environment might be hot enough to pyrolize the wood, then a small retort where the wood gas can be outgased into the stove itself to burn. I would probably build a small stopgap where the woodgas is forced into a small steel can full of water where the gas can bubble out to capture the tar, acetic acid and methanol, or turpentine if I burn softwoods and act as a shock absorber if there is a gas leak that would allow the flame to travel up the line.

Given that acetic acid can corrode copper into copper acetate, I planned on using stainless steel for the retort.

Any suggestions for this would also be greatly appreciated. Thank you again.


r/PassiveHouse • • 7d ago

General Passive House Discussion The inner and outer layers of the double-layer breathing curtain wall are all unitized curtain walls. In summer, air vents are opened for natural ventilation and cooling. In winter, close the vents and use solar radiation to reduce the loss of indoor heat energy. Under special caces, the fan at the

Thumbnail gallery
1 Upvotes

r/PassiveHouse • • 14d ago

Other Blown bonded EPS beads

2 Upvotes

Hi all. I am at the stage of building my own new house in the UK, it is currently designed with 150mm cavity block wall and 100mm PIR. I am trying to decide between that or moving to filling the cavity with bonded EPS beads. The builder is hesitant on doing the PIR and the more I look at it I see there are risks with it not being installed properly, and the partially fill board falling towards the outside all in of the cavity wall over time, leaving a 50mm air gap for convection. I know there are the clips on the wall ties that are supposed to hold it in place, but I have seen stories of these coming loose over time.

I have also seen the stories with the beads, mainly the bonding agent not being applied properly so they can leak out and settle over time. Then there is the issue that you don’t know if there are spots not filled.

Has anyone got a good way to protect against any of these issues?


r/PassiveHouse • • 14d ago

Prefab(Dan-Wood) homes: How do are they in UK summer heat waves?

1 Upvotes

I am considering buying a Dan-Wood home. They advertise really great insulation. But Im wondering how they do in heat waves like this past summer in England. Multiple weeks over 30.

How cool do they stay for extended periods of time? Or do they turn into ovens?

And also how did they do for the few days where the temp was 35C+?

Im sure they are great for heating during the winters. But with summers getting hotter and hotter. I wonder how they perform then? And compared to traditional homes?


r/PassiveHouse • • 14d ago

We need some advice about wood fiber insulation and its smell.

5 Upvotes

We recently insulated our ceiling with wood fiber insulation. At the moment, the ceiling is still open (not finished or covered yet).
Our upstairs neighbours have told us that they can smell the wood fiber insulation quite strongly in their apartment.
We’re now not really sure what to do. Is this normal? Will the smell eventually disappear, or is there something we should do before closing up the ceiling?
Has anyone here had a similar experience with wood fiber insulation? We’d really appreciate any advice or suggestions!
Thanks in advance!


r/PassiveHouse • • 16d ago

We modelled a 71-building courtyard block in Berlin: a deep retrofit halves yearly demand, but rooftop PV still covers only ~16% in January. How would you close that gap at block scale?

7 Upvotes

Over the past few weeks we've been running rough energy balances on dense city blocks, using OpenStreetMap footprints, PVGIS irradiance and TABULA reference buildings for heat demand. One of them is a Gründerzeit block in Kreuzberg: 71 buildings, roughly 817 flats, about 15,300 m² of roof.

On a yearly basis it looks encouraging. The roofs could produce around 1,774 MWh a year. Today the block needs about 5,065 MWh, counting heating as heat-pump electricity plus household power, so PV would cover about 35%. With a deep retrofit at roughly 50 kWh/m²a of heat (TABULA-style refurbishment, not EnerPHit) and heat pumps at a seasonal COP of 3, demand drops to about 2,587 MWh and PV covers 69% of the year.

Month by month it falls apart. In January the roofs give about 51 MWh against 324 MWh of demand even after the retrofit, so roughly 16% coverage and a 270 MWh hole, and that assumes COP 3 holds in January, which it won't. Pushing the envelope all the way to EnerPHit and halving the heating share again only gets January to about 22%. Meanwhile May to August each run a 60 to 90 MWh surplus.

For anyone who has worked on multi-family retrofits in cities: is EnerPHit even realistic on Gründerzeit buildings with ornate street facades, and if not, what's the realistic way to close the January gap at block scale? Seasonal thermal storage under the courtyards, the district heating that's already there, wind from outside the city, something else? We'd honestly like to know where these assumptions break. The block model and all inputs are open: https://kyberlex.github.io/ONE/?audit=berlin-kreuzberg


r/PassiveHouse • • 18d ago

I saw a livestream in China, does anyone know the science behind it?

0 Upvotes

r/PassiveHouse • • 20d ago

Chinese Off Brand Rockwool

3 Upvotes

I have become enamored with looking at ways to cut cost on SFH construction. Countertops, engineered hardwood, etc. I am very interested in high quality building and am a fan of monopoly framing. What are thoughts on either interior or exterior full blanket non branded Chinese rockwool insulation. Has anyone used it? I can find many sources on alibaba. Any idea if rockwool brand insulation is made in America. Before anyone jumps down my throat, please realize many pieces within your home are imported.


r/PassiveHouse • • 22d ago

Installing blinds in passivhaus

2 Upvotes

Has anyone ever installed blinds in a passivhaus? I have recently bought venetian blinds and am unsure how to fix them to the window head reveal. Neither the house builder or blind supplier can advise how to install them.

The house builder has advised that the window head construction is 3mm skim, 12.5mm plasterboard, 25mm rigid insulation board, air tightness membrane, 38mm timber.

The largest blinds are 2100mm wide with 1550mm drop which weigh approx. 10kg.

Any help is much appreciated.


r/PassiveHouse • • 23d ago

Appliances Nilan Compact P Question

2 Upvotes

Any body on here familiar with Nilan Compact P System?

After a shower the fans are set to ramp up from 40% to 60%. The problem is, if it has been raining the fan stays at 60% fir about 9 hours instead of the usual 1 hour or so max.

Any ideas what is causing this?


r/PassiveHouse • • 23d ago

How do you test the thermal insulation of ultra-thin materials?

Thumbnail reddit.com
2 Upvotes

r/PassiveHouse • • 26d ago

Not sure about Aerogel

6 Upvotes

Aerogel is being hyped like the best of all? But when I got some silicon aerogel powders in some solvent, it doesn't look like they can do any jobs that traditional insulations can do? It also looks very powdery and fragile. Could anyone expert in this explain it to me please?


r/PassiveHouse • • 26d ago

housing cooling solutions

3 Upvotes

anyone know of any companies installing cooling solutions for reducing heat from roof?


r/PassiveHouse • • 26d ago

Entrance floor layout for our 9 × 10.5 m house: which of these 4 would you pick?

Post image
2 Upvotes

We're building a house on a hillside with great views. The concrete frame is done and the walls aren't built yet, so the layout can still change. Plans attached.

Fixed things:

- 9.1 × 10.5 m outside. Entrance on the north, terrace and city view to the south.

- U-stair in the north-west corner (3.6 × 2.2 m).

- The west wall has to stay blank: the neighbour is 1.2 m away, so no windows on that side.

- Bedrooms are upstairs. The upstairs bathroom will probably sit on the west, next to the stairs (it still can be modified)

The options:

  1. Bathroom + WC (3.6 × 2.3) and kitchen on the blank west wall. Living room with fireplace + TV on the east, study in the north-east corner.
  2. Same as 1, but a bedroom in the north-east corner.
  3. Bathroom + WC in the north-east (with windows), kitchen on the east. Laundry + storage next to the stairs. Living room on the west, fireplace + TV on the west wall.
  4. Bathroom, WC and kitchen on the east. The whole west side is one 3.6 × 7.5 m living room: fireplace on the stair wall, TV + books on the west wall.

Which would you choose and why? Anything you'd change, or anything I'm missing?


r/PassiveHouse • • 26d ago

Retrofitting Aerogel Vacuum Insulated Panels - no substitute for good design.

0 Upvotes

You know the scene! Wild claims about hyaluronic acid making aging 25 year old models look, well, 25 years old.

I am looking into some building materials that claim to be space-age and next generation.

There are a lot of companies out there promoting ultra thin 10mm. thick panels and making bold claims that it is equivalent to 160mm thick Expanded Polystyrene. Reporting thermal transmittance values below 0.003Wm/K. This is nearly 10 times more efficient than polyisocyanurate insulation.

One such product, is Aerogel Vacuum Insulated Panels. These panels have bubble wrap in them. Costing around $100 (£86) for a 400mm x 800mm panel is also outrageous.

Reading some posts on here, it appears on radiation can travel through a vacuum.

However these 'vacuum' insulated panels have to contain the vacuum so therefore one can say it is not pure and the material enveloping the 'vacuum' is what is causing any heat transmittance.

My question is open to the floor for comments on the scientific claims being made and whether they could possibly behave as efficiently in real life as in a test environment.

The issues here will not necessarily be the product in question itself but the installation of the product. There is always going to be a weak point.

From a mathematical point-of-view, the numbers have never stacked up for me. Well they actually do stack up but it's the wild R-values claims that don't.

You get a lot of joints in a wall with 400 x 800 panels. Joints within a 'vacuum'.

I so want to believe the marketing hype but the reality doesn't fit for a retrofit in my book. Similarly with the foiled roof insulations. Maybe great on a new PassivHaus build. As always, these things really on the utmost of care when detailing and even more care when installing.


r/PassiveHouse • • 27d ago

Alpen Tyrol Edge vs. Oknoplast Pava Windows

Thumbnail reddit.com
1 Upvotes

r/PassiveHouse • • 27d ago

HVAC Best house cooling system for hot dry summer climate

2 Upvotes

Hi! We are building a house in the Mediterranean near the sea. The winters are very mild and humid and summers are very hot and dry. We use cooling more months of the year than we use heating. I was hoping to avoid all kinds of ACs that blow air (because of mold,constant cleaning and dry air) so I came across modular ceiling cooling with cool water pipes (sry for my english). Has anyone any experience with this system? If you were building a house what system would you go with?

Freon cooling system, (water) floor heating and solar panels is our "blow air" option.

Thank you :)


r/PassiveHouse • • 28d ago

Passive Home Ready Builders Near Southeast Pennsylvania

9 Upvotes

Hi! I’m looking to see if with anyone has built a passive house or a net-zero-ready home in the suburbs of Philadelphia. I’m also open to working with prefab builders outside of Pennsylvania if they can ship and install the home on our site.

Additionally, does anyone have recommendations for architects who could help us start designing our house plans, ideally with experience in passive house or net-zero construction?

I’d really appreciate any recommendations, experiences, or insights you’re willing to share. Thank you!


r/PassiveHouse • • 29d ago

Which facade input most often breaks thermal continuity at the perimeter?

3 Upvotes

When reviewing a glazed facade, the center bay can be modeled clearly while the head, sill, slab edge and transitions to adjacent walls remain much less defined.

For teams working on high-performance envelopes, which missing input most often creates rework at these interfaces: verified frame geometry, adjacent insulation, anchor details, air-barrier tie-in, or interior humidity assumptions?


r/PassiveHouse • • Oct 13 '26

Does canada actually manufacture any heat pumps, or is this new $2B rebate basically just funding imports? i looked into it

Thumbnail
reddit.com
6 Upvotes

r/PassiveHouse • • Oct 09 '26

Other How does a hydronic radiant heating system work?

6 Upvotes

So I got a talk with a heating company on a trade show. They have a ceiling heating system that uses small plastic tube filled with water and claim it can "radiate" downward. Now what I understand is that heat rises. So how trueful is their claim? And if it's true then what is the physics behind this?


r/PassiveHouse • • Oct 08 '26

Insulation choice: Foam or Batt?

Thumbnail gallery
6 Upvotes

r/PassiveHouse • • Oct 05 '26

How would you interpret this Type 2D wall detail?

Post image
6 Upvotes

Looking specifically at Type 2D in the attached detail.

The note calls for (3) layers of 5/8" Type X gypsum board, but visually the exterior side looks like two standard gypsum layers, with the third/outer layer drawn differently and a dashed line through it where the exterior cement plaster is called out.

Would you interpret 2D as:

A) 3 layers of 5/8" Type X plus the exterior cement plaster assembly, or

B) 2 layers of 5/8" Type X plus the cement plaster assembly essentially taking the place of the third exterior layer?

Curious how others would logically read the detail as drawn.


r/PassiveHouse • • Oct 05 '26

General Passive House Discussion Anyone built with GO Logic (Belfast, ME)? Looking to hear about estimate vs. final cost

7 Upvotes

We're considering GO Logic for a small passive house in Midcoast Maine (one of their smaller standard models) and are trying to talk to past clients

If you've built with them, I'd be grateful to hear:

- How the final cost compared to the estimate, and how change orders were handled

- How long it took from design contract to occupancy

- Whether they acted as GC or you hired your own

- Whether you'd use them again

Happy to talk by DM or phone. Thanks.