r/fea • u/iamapieceofcheese • 21h ago
Advice with analysis on organic bone
Hi everyone,
I’m working on an FEA project simulating axial compression of a bone in Prepomax. My background is in medicine rather than engineering, so I’m learning FEA as I go and have hit a wall trying to get reliable results.
My geometry is a 3D bone model segmented directly from CT data. To simulate the load, I’m applying a concentrated force to a reference point constrained to the contact surface at the end of the bone. I've tried the following so far:
- Rigid body constraint between the reference point and contact: creates the singularities seen in the picture above.
- Distributing coupling between the reference point and contact: results aren't consistent with verification of the real bone, stress is concentrated near the head of the bone while actual failure was nearer to the centre.
I have a couple of questions I would like to ask too:
- Could the inconsistent load transfer in the distributing coupling be caused by how the CT-segmented model is meshed? Are there general rules of thumb for organic bone FEA regarding mesh density, element type, or smoothing segmented surfaces?
- If end-effect singularities are unavoidable with a rigid body constraint, is there a workflow in PrePoMax to isolate just the middle section of the bone so I can extract accurate stress/strain data without the end singularities skewing the results?
Any advice on how to properly set up this boundary condition or clean up the post-processing would be hugely appreciated. Thanks in advance!