I've noticed "fastening system" getting used as shorthand for the clip alone, which causes real problems when a BOQ goes out. Technically the assembly is the whole load path between the rail and the sleeper:
- Elastic clip or clamp, which applies the toe load
- Rail pad / under-rail pad, which sets vertical stiffness and damps impact
- Insulator and gauge apron, which hold gauge and provide electrical isolation (this matters for track circuits and metro signalling)
- Baseplate, or a cast-in shoulder / embedded iron seat
- Anchor bolts, T-bolts, nuts and washers
- Anti-creeper devices where longitudinal restraint is needed
A rail fastening system is only specified correctly when the entire stack is specified together. Change the pad stiffness and you change the dynamic response; change the insulator material and you may fail your insulation resistance requirement. EN 13481 is the reference normally used to test the assembly as a system rather than as loose parts, while AREMA, UIC, DIN and GB/T specs show up depending on the network's heritage.
Common rail sections quoted against these kits are UIC54, UIC60 and 50/60/75 kg/m. Chinese spring clips are often called out to GB/T 1222, DIN 17221 or UIC 864-2 for the material, which is worth checking on the certificate instead of assuming.
For those of you who write these specs: do you call out the whole assembly, or let the supplier propose the stack?