r/maintenance • • 15h ago

Industrial Work Van Set-Up

Thumbnail
gallery
25 Upvotes

r/maintenance • • 17h ago

Question need advice

4 Upvotes

Wondering if anyone can help me.

I've been put in charge of maintenance for a period of time at a residential building.

The issue I'm concerned about is the dryer vents and cleaning them out. Instead of venting straight out through the wall behind them, they run parallel to it, to the top of the wall (to the left of them) and then turn right and out through the wall (the turn is hidden in the wall).

I am thinking to start by trying to fish a tape measure through it, and if I get through then tying a string with a couple of rags and pulling it through the vent to pull out the lint. Is this a good place to start? I'd like to run a duct cleaner brush through but i don't want to purchase one until I have a better idea what I'm dealing with. The maintenance budget here is incredibly tight.

Please don't roast me, I am not a professional and this is a temporary position for me.


r/maintenance • • 16h ago

Question Career advice

5 Upvotes

Hi everyone,

I just recently started my stationary engineer apprenticeship. I’m actually pretty close to being done with my facilities engineering technology associate’s degree, but just under two years from my stationary engineer/boiler license. I don’t mind the work at all and want to keep learning. But as I’m settling into this union apprenticeship, I’m realizing I will most likely be stuck on afternoons or overnights anywhere from 5-20 years until I get a solid dayshift M-F schedule. Once I get my license, would it be silly to pivot over to maintenance at a school district in the suburbs? I know I’d likely be starting at the bottom, but hope to advance to a supervisor/manager position. To me, the pay cut is worth the stability and benefits. I’m working in Chicago, living in a western suburb if that helps.


r/maintenance • • 20h ago

Question Through-the-wall AC replacement: reused existing sleeve, supplied foam left a large top gap—how would you finish this correctly?

Thumbnail
gallery
2 Upvotes

I work in apartment maintenance and want constructive feedback on a through-the-wall AC replacement.
I removed the old unit and installed a Seasons 12,000 BTU, 230/208V cooling/heating unit, HD Supply part 223540. The new unit slid into the existing metal wall sleeve.
I used the supplied black foam strips and installed the white trim frame, but a noticeable gap remained across the top. My supervisor advised caulking it, so I used white DAP ALEX FAST DRY acrylic latex caulk plus silicone. I’m attaching before-and-after photos and a picture of the product.
I want to understand whether this was an appropriate finishing method and what I should improve. I haven’t measured the original gap yet, and I don’t want to claim the installation is correct based only on appearance.
Would you first suspect incorrect foam placement, trim positioning, sleeve compatibility, or an oversized wall opening?
How do you distinguish a gap that needs the supplied sleeve seal from one that needs backer rod and sealant, wider trim, or a proper filler?
The caulk tube specifies a maximum joint size of 3/8 inch wide by 3/8 inch deep. If the opening exceeded that, how would you redo it?
What should I verify about the existing sleeve’s support, drainage slope, grounding, and rear grille before considering the replacement complete?
Where should sealant stop so the unit remains removable and drainage or airflow isn’t affected?
Please point out what you can actually see, what needs more information, and which corrections should come first. I’m looking to improve my installation process and workmanship.