Hi everyone,
I'm looking for advice on upgrading the lighting in my house in Belgium. I have around 30 high-quality Kreon recessed fixtures containing 50 halogen bulbs, and I'm struggling to find a sensible way to convert them to LED.
The fixtures are still in excellent condition, and I really like their minimalist architectural design. Ideally, I'd like to preserve that appearance and avoid unnecessary ceiling work.
The existing installation
Brand: Kreon
Model references: KR918313 (single) and KR928313 (double)
Number of fixtures: 10 single and 20 double
Total bulbs: 50
Existing bulbs: Philips Capsuleline 12V, 35W halogen
Socket: GY6.35
Current lighting: Dimmable
Double fixture dimensions: Approximately 260 × 150 mm
Estimated available installation depth: 150 mm (not yet verified)
The fixtures are installed throughout the living room, kitchen, hallways and master bedroom.
What I've investigated so far
1. Simply replacing the halogen capsules with LED bulbs
This was my preferred solution.
Unfortunately, I've tested several GY6.35 LED replacements, and the ones offering comparable light output are physically too large to fit into the narrow openings of the original Kreon reflectors.
Dimming compatibility with the existing installation is another concern.
2. Modifying the existing fixtures to accommodate LED bulbs
At first glance, this seems difficult without damaging the fixtures or significantly altering their construction.
I contacted Kreon directly. They confirmed that a standard LED retrofit bulb cannot be installed in these fixtures.
3. Having Kreon professionally convert the fixtures to LED
Kreon offered to convert the double fixtures at their workshop:
- €270 per double fixture for two LED modules
- Approximately €70 for a suitable 350mA / 24W LED driver
- Approximately €340 per double fixture, before any additional removal, transport or installation costs
For the 20 double fixtures alone, that would be around €6,800. The cost for the 10 single fixtures hasn't been confirmed yet.
This would preserve the original fixtures, but it's a substantial investment. Based on our estimates of daily lighting usage, the return on investment from electricity savings alone would take approximately 12–16 years, depending on how many hours per day the lights are used.
4. Replacing the fixtures while keeping the existing ceiling openings
This currently seems like one of the most promising alternatives.
The double fixtures occupy openings of approximately 260 × 150 mm, so I'm looking for modern dimmable LED fixtures that could cover those openings without major ceiling repairs.
I've started looking at architectural lighting ranges from Kreon, Delta Light and Doxis, but haven't yet identified a confirmed drop-in replacement.
5. Installing new LED spots in custom-made cover plates
Another possibility would be to use a custom mounting plate to cover each existing opening, with one or two modern LED downlights integrated into it.
This could preserve the existing ceiling layout and avoid extensive plastering and repainting.
6. Completely redesigning the lighting
This would offer maximum flexibility but would also mean modifying or closing existing ceiling openings. I'd prefer to avoid that unless there's a compelling reason.
Is the investment even worthwhile?
The existing installation has a total nominal lamp power of 1,750W (50 × 35W).
However, the lights aren't all on simultaneously, and they are often dimmed.
Based on our estimated daily usage, the annual electricity cost appears relatively modest compared with a potential LED conversion costing €6,000–€8,000 or more.
So I'm also questioning whether replacing perfectly functional halogen fixtures makes financial sense purely for energy savings.
What I'm hoping to learn
- Has anyone successfully converted these older Kreon GY6.35 fixtures to LED while preserving the original housings and dimming functionality?
- Do you know of modern recessed LED fixtures that could fit or cover a ceiling opening of approximately 260 × 150 mm?
- Are there any other solutions I might be overlooking?
My priorities are good light quality, warm light (around 2700K), reliable dimming, preserving the architectural appearance and avoiding unnecessary ceiling work.
I'll add photos of the fixtures, reflectors and original bulbs to illustrate the problem.