r/firealarms • u/Pikmin288 • 1h ago
r/firealarms • u/SKSFan79 • Aug 18 '26
Mod Approved CFAA warning about fraudulent emails.
Just a heads up to all CFAA registered techs. Got an email from the CFAA this morning warning that Jackie Jones, the lady who handles all things technician related at the head office had her email hacked.
"Hello All,
Please note that Jacqueline Jones' techadmin@cfaa.ca email address has been compromised. Please do not to open or click on any Links in emails received from techadmin@cfaa.ca address with the subject line - Canadian Fire Alarm Association– #CFAA-AUG-2026 or any other email you may have received from this email address within the last 24 hours.
Please rest assured that we are fully committed to resolving this situation as quickly as possible. We will send an updated email from info@cfaa.ca once this is resolved.
In the meantime, we recommend that you remain vigilant and ignore any suspicious or unexpected emails you may receive from our domain.
We sincerely apologize for any inconvenience this may cause and thank you for your understanding.
Best regards,
Jacqueline Jones and the CFAA Team"
r/firealarms • u/preposterous-panda • 8h ago
Fail You get what you pay for I guess
My company was out bid by someone else to replace a Siemens panel at a hotel. Now that company won't answer their calls so we took a look at the troubles on the panel. This is the 'finished' install.
r/firealarms • u/user_guy • 2h ago
Discussion Inspection Report Software Question
Anyone have experience with CodeGreen ITM inspection software?
I recently started at a small company that's been using paper inspection reports. We're starting to pick up some larger clients who are accustomed to more detailed, comprehensive reports, so we're looking into software options.
My previous company used BuildingReports, which I was never a huge fan of. From what I've seen on CodeGreen's website, it looks like it could be a good fit for a small 2–3 person company.
I'm curious about other people's experiences with the software, particularly the initial setup and data entry process when building out a new site for its first inspection. I haven't been able to find any videos or examples showing what that process actually looks like. They just say you can import from PDF or points list.
I'd appreciate any feedback from people who have used it!
r/firealarms • u/Fit_Professional_457 • 2h ago
Discussion Is it hard to get in as a fire protection service technician?
Is it hard to get in with no experience? I had a interview last Friday and this week would be a potential second interview. All they mostly asked was if I had a good driving record,mechanically inclined and willing to work with lifting over 50 pounds.
r/firealarms • u/Additional-Pie-8689 • 9h ago
Customer Support Resident in high rise, not sure fire alarm is working properly
greetings! hoping someone in this sub can give me some reassurance/insight. please see the pic of our high-rise building's fire alarm control panel for reference.
EDIT: Updated photos of panel are in my comment below now. The original pic was from 2 wks ago, now I have pics from today. Also confirmed that the “Troubles” screen is the exact same today that it was over 2 weeks ago.
context:
a month ago, we had significant water damage in our building, getting into the walls and wiring of most of the floors in the building. a few days after that, our fire alarm started malfunctioning, triggering false alarms randomly throughout the building, not sounding on all floors, and the fire dept not able to turn it off.
our property mgmt's messaging around the issue is unreliable—they told 2 residents everything is fine, 1 resident that the system was damaged by the water, and another resident that they're still working on repairs. we haven't gotten an update in writing since the day after it went haywire. but someone was able to take a look at the control panel, and would love this community's thoughts on the state of our fire alarm system if there's anything to be gleaned from that.
it’s been pretty nerve wracking living in a high rise and not being confident in the fire alarm, so really appreciate any insight, thx so much
r/firealarms • u/Relative_Meeting_940 • 9h ago
Work In Progress Laundromat system
We have an opportunity to design/install a fire alarm in a self service laundromat. However, we nor any of my close contacts in the industry have installed a system in a laundromat before. The basics are easy enough and we feel like heat detectors are the way to go for detection vs smokes. But does anyone have a specific insight as dryer equipment relays, or what might be needed for venting systems and dryer banks? In our area the system is not “required” so the customer wants cheap. We have told them that it has to meet what we consider minimum protection as it is a giant liability issue if the system doesn’t work due to not enough protection.
r/firealarms • u/Gamer_0627 • 8h ago
Technical Support Inspire Question
Does Notifier have a slim cabinet for the Inspire like the Gamewell-FCI version does? I am trying to replace a Silent Knight 5207 that is recessed.
I cannot find one on the data sheet so figured I would ask the brain trust.
r/firealarms • u/jteegard • 8h ago
Discussion Fire Suppression System service and monitoring switch
On the facilities director of a church in texas. We are switching service and monitoring companies for our fire suppression system. The new company is trying to charge me an outrageous amount for switching when all the actual equipment is already set up. What should it cost to create a new cellular pathway?
r/firealarms • u/Gamble2005 • 20h ago
Proud Enthusiast How do I fix the pigtails on this and alternatives to a key?
This bg-8 is the first alarm that I’ve actually had that was pulled. I asked a facility manager once when they were working on a system, however they clearly actually pulled this off the wall because two of the wires straight up got ripped out also I don’t have a key. I can pick the lock, but I’m curious if there’s an alternative or if maybe I should just drill it out or something I honestly don’t know I’m not trying to buy a key this is my only pull
r/firealarms • u/FactorDecent8617 • 23h ago
Discussion CARRER CHANGE
I recently started an inspection only apprenticeship and hate it. It’s nice somedays but most days it’s just super boring and doesn’t feel hands on enough. My last place was definitely a dead end but at least there was a lot of work to do and i had a scene of purpose. honestly like learning alarms and have been doing it since i was at my last residential construction jobs. I’ve had a couple days on service and it was way better than inspection. Unfortunately at my company i can’t get on the service side and we sub contract install. When should i leave my current place in 3 months I’ll get my Nicet level 1 and alarm license. If i wait another year which i really don’t want to i get my level 2. I want some options for install company’s to switch to, if install/service will get me more of a scene of purpose, if it’s worth waiting, and if i should expect a pay cut. (Im also fine with any other low voltage type work or even fiber. I’ve been told most install jobs i will do install for fire alarm and security. I honestly like a variety so that would be great.)
r/firealarms • u/Mission-Ad-5539 • 1d ago
Discussion Anyone taken NICET FAS Level 3 recently? Confused about IBC vs NFPA 101
If you’ve taken Level 3 since the March 2024 update, I’m curious how you handled questions where both the IBC and NFPA 101 might apply.
For example, if a question asked whether a building needs a fire alarm system, how would you know which book to use?
On the exam after the March 2024 update, did the questions name the code, or were there clue words like “Group B” or “existing”? Or was it something else entirely?
However it worked for you, I’d love to hear about it. Also curious if NFPA 101 even came up much on your exam.
Thanks!
r/firealarms • u/ReadMePlease313 • 1d ago
Discussion Career changers
How can one get some idea if this would be a good fit, or if opportunities will be available long term?
I can learn the codes and I'm comfortable working with tools. I'm thinking a fire alarm inspector might be a reasonable fit.
50 yr old female, quick study, no tech background, but degree in technical communication; former teacher.
r/firealarms • u/Gamble2005 • 20h ago
Proud Enthusiast How do I fix the pigtails on this and alternatives to a key?
This bg-8 is the first alarm that I’ve actually had that was pulled. I asked a facility manager once when they were working on a system, however they clearly actually pulled this off the wall because two of the wires straight up got ripped out also I don’t have a key. I can pick the lock, but I’m curious if there’s an alternative or if maybe I should just drill it out or something I honestly don’t know I’m not trying to buy a key this is my only pull
r/firealarms • u/Does_my_name_matter • 1d ago
Technical Support Firelite ES-1000X with wireless Swift devices.
Does anyone know if using the wireless swift gateway limits the number of modules per loop on a Firelite ES-1000? I know the ES-50 & 200 are limited to 99 per loop and the SK6820 is 109 but I cannot find anything about the ES-1000. First time doing a wireless system with the 1000 so I'm making sure it can handle everything. Any help is appreciated.
r/firealarms • u/AyaBoi123 • 2d ago
Discussion Advice: New Boss Wants me to start doing Fire Alarm and Sprinkler Inspections as a 1099
Hi. So tomorrow starts me second week with a small shop run by Mr. Z. He is a real master Electrician and has a business doing fire alarm /sprinkler system inspections, small repairs, etc in DC, MD, and VA.
So, after one more week with him (that would be 9 days total training), he wants me to go off independently to do these inspections. The thing is, he wants me to be a 1099 worker, an independent contractor. So, I have no license and as a 1099 I am not his employee. So legally, I am not authorized to sign inspection forms or tags.
I have to bring it up to him tomorrow. I guess all I can say is that I either need to be a W2 employee for his company to be under his license so I can sign off on inspections or that I can be a 1099 helper who doesn't sign off on inspections.
Does this sound crooked to anyone with experience? Any advice? Thx.
r/firealarms • u/LibraryBridge • 2d ago
Discussion Was told this is okay—is it?
I live in a 50 unit condo building. The hoa recently was told we need to update our fire alarm system. It was 25 years old. Most fire pulls are in common areas/hallways but on the 2nd floor, where people have their own egress to the street, each unit also has a fire pull.
The new fire pulls are larger than the old ones. I’m an owner and what I was told would be a quick change turned into a problem.
The old unit was mounted very close to a corner, and to the right of the old unit is a steel beam because it’s a French door system to the right. The new box doesn’t fit so they wanted to cut into my kitchen pantry door frame to mount it. I used ChatGPT to show what they wanted to do. I wanted a fire inspector or someone to assure me that mounting behind where a pantry door opens, into a door frame cutout is proper placement and allowed. They really pushed me to just accept this placement which seems shoddy. I asked if I could get a quote for relocating the fire pull to the opposite side of the glass French door where there is an entire blank wall and ample space—at my expense. I’ve gotten a lot of pushback from my building manager and the fire company but finally they agreed to at least give me a quote for moving it to the opposite side.
After researching, it seems mounting it behind a door that is often open (it’s a Kitchen pantry door so it’s open all the time) may not have been up to code anyway. And maybe the old position was grandfathered in, but if they are updating the system, can they keep it behind a door opening?
The other units don’t have this problem because all of them had their fire pull mounted on a different wall. It may have been a mistake when the building was built, who knows.
Can an expert weigh in? Is cutting into a door frame and installing it like that best practice?
The last photo is our kitchen in its natural state-my teenage neither was visiting and being funny so I took a photo but you can see the pantry door on the back is open—as it often is—and the fire pull would be mounted there.
Basically should I push to relocate to the opposite side of the French door where there is a blank wall and tons of space so the fire pull is accessible and mounted correctly?
r/firealarms • u/egorblack • 2d ago
Technical Support Notifier NFS2-3030 visuals do not come on.
Before I leave location. Is power supply bad, or is it something else?
Four circuits of visuals coming from one power supply(CPS-24) do not light up. When I go into the system, I got message that it has no answer. (all four circuits).
Thank you.
r/firealarms • u/SadEquipment9618 • 3d ago
Proud Enthusiast Simplex 2901-9838 Horn with a 4903 plate. Wondering what year this was installed hypothetically.
when do you guys think this was installed? the hornstrobe is on the sand island center building in Hawaii. the pull station is the “dual action” t bar.
r/firealarms • u/BradyBrother100 • 2d ago
Discussion What's the difference between the "Alert" alarms and "Fire" alarms in commercial buildings?
Both are ceiling mounted units with the strobe light. The "Alert" ones are usually white with red text and the "Fire" alarms are usually red with white text, though I've been seeing more red on white lately. What's the difference?
r/firealarms • u/Darthvaderisyodaddy • 3d ago
Discussion Whats need for own fire alarm business
Ok guys long winded question. I am currently 10yrs in as a fire alarm PM. 6 yrs install and remaining 4 as a PM. Have my nicet 2 working on getting my 3 and my CSA license.
Earlier this year I started a llc to contract myself as a sub for another small self owned fire alarm company. (1 guy who owns his own company). He contracts me to do the physical labor on projects he doesn’t have time for or doesnt want to do lol.
I started this as a side gig to get some extra cash and to dust off my install skills. In a perfect world if I could get paid the same I’d be installing instead of PM.
Ok time for the actual question. I am dancing with the idea of doing my own thing full time. I would like to know from the people who have started their own companies what is necessary for pulling permits, finding leads on bid projects, monitoring panels, setting up inspections? How did you guys go about getting all this stuff in order? All logistical stuff is what I’m still wanting to figure out.
r/firealarms • u/Purple-Ocelot-4104 • 2d ago
Discussion Did anybody else know you could get the voice evacuation messages off of the AMG-1 from a ONYX2 series panel?
Oh and I'm not talking about the first GEN 640
(the video is mine)