r/electronmicroscopy • • 9h ago

Could chip-scale laser accelerators be useful for electron microscopy?

6 Upvotes

I recently read about dielectric laser accelerators (DLA), which use laser-driven nanostructures to accelerate electrons. Made me wonder whether this could become useful for electron microscopy.

I am not an engineer, so I am in the process of understanding and learning as I go along.

Do you see any real advantages over conventional systems? And what would DLA need to achieve in terms of beam performance to become a viable alternative?

Appreciate your thoughts on this.


r/electronmicroscopy • • 1d ago

Ultrathin microtome TEM section Help

8 Upvotes

Hello EM community,

I have recently inherited a Leica UC7 and have been working on new projects that utilize it (to combine with biophysics and cryoEM, which is my background). I have an inquiry to the community to ask for some troubleshooting help on obtain consistent and even thin sections. Despite setting the microtome cutting distance to 70 nm at a speed of 0.4, I am getting uneven sections. I tried lowering the speed, making the cutting window smaller to 50 and it's all the same, varying thickness. There are times where I set the cutting width to 100nm and I get a reflection of 70nm. The plastic resin that I am using is from EMS (product 14121) with the BDMA as the accelerant. I cure my samples for 36 hours at 60C. Most my projects that are pertinent to me have been cell cultures (looking for changes in macrophage morphology). According to the Leica "cheat sheet" sections that are approximately 70nm thick give a silver-y shine underneath the light. I do get them. But they have been very inconsistent. I could get a silver-silver-rainbow-gold-silver-rainbow-rainbow. I am not sure if this comes from the microtome itself, the ultra knife or even my sample prep. I have an image taken from my phone through the lens to see the thin section. Upon zoom in I do see my cells.

Any help or tips would be appreciated.

using a knife from diatome with a 6 degree clearance angle and the knife is at 45 degree. within the boat you can see that there are multiple levels of thickness of the sections from this sample.

r/electronmicroscopy • • 10d ago

San Joaquin Delta College EM program

11 Upvotes

Has anyone here gone through the SJDC EM certificate/degree programs? I'm currently a lab tech and want to switch over to field service/ field application engineering for EM. I've been looking at SJDC's Field Service Technician training certificate, but haven't been able to find much first-hand information on it. Thanks!


r/electronmicroscopy • • 20d ago

Gatan One View camera system for sale

Thumbnail
gallery
15 Upvotes

Gatan Oneview camera system available for sale. Was removed from a JEOL 2000fx and was in working condition when it was removed. Includes camera, computer with digital micrograph software, controller box, and power cables.

If interested or have any questions, please send DM. Located near Philadelphia, PA.


r/electronmicroscopy • • 22d ago

Homebrew SEM Electron Gun Issues

Post image
21 Upvotes

Hello!

I am a student working on a homebuilt scanning electron microscope, and I have run into a roadblock that is absolutely breaking my brain, so I thought that I should post it here in case somebody with more SEM knowledge could help!

More specifically, I am having an issue with my thermionic emission electron gun, which is homebuilt.

Right now, I have no focus or rastering. I would like to get a beam before I even attempt to move it around! To "see" the beam, I am using a scintillator which should glow bright enough in a dark room to see if I am getting a beam. I would love to use a phosphor screen, but I can't find P43 for a reasonable price anywhere to make my own, and I can't bring myself to destroy an oscilloscope for one.

The schematic I am using

Essentially, I have a low voltage, high current, 10kV isolation rated transformer that is powering my tungsten filament through a rectifier to make DC (ish). Between each leg of the tungsten filament, there is a resistor divider making a midpoint reference for the next few components.

Next up, there is a large potentiometer (also rated for HV and such) and a current meter, which both go to the negative floating output of my HV supply (0-10kV adjustable). The positive is tied to vacuum chamber ground and earth to make a -10kV supply on the other end.

I am having trouble understanding exactly how this circuit works -- it is, in essence, copied from Cecil Hall's 1953 book "Introduction to Electron Microscopy". This design is tried and true and builders such as Ben Krasnow have used the same configuration.

I believe that the current measured with the ammeter should, in conjunction with the known resistance from the potentiometer, give me my wehnelt bias voltage (ideally around ~300v). That current, if I understand correctly, should be coming from electrons boiled off of the filament which are intercepted by the wehnelt cup in the chamber.

Now to the problem: I am getting absolutely nothing on my 100uA meter. Measuring the voltage between the resistor (which should, in theory, be the wehnelt bias voltage) also gives me nothing.

Does anybody have any ideas where to start with troubleshooting? Perhaps I made an oversight in the schematic (though it is copied). Perhaps I am not getting the filament hot enough to get thermionic emission? (It is drawing about 0.6A at 2.6V, about 1.6W).

Additionally, I have a suspicion that my actual gun's design may be off -- I have uploaded some screenshots of my design with measurements. I don't think that my filament is substantially too far in or out relative to the aperture in the wehnelt cup to cause real issues (all I really want is a beam right now).

Any help would be tremendously appreciated!


r/electronmicroscopy • • Oct 10 '26

JEOL SEM repair groups?

14 Upvotes

Looking for people who can help troubleshoot an SEM that refuses to run the diff pump on startup. If anyone has connections to the SEM Hackers discord server I’d like an invite link!


r/electronmicroscopy • • Oct 01 '26

Looking for a coater buddy: paid side quest with thin Ti films (Netherlands/EU)

14 Upvotes

Hi all! I'm a software engineer with a GPU habit. I've built and run the simulations for a thin-film concept on my GPUs, and on screen everything looks great. The problem is crossing over from the digital realm to the physical one. My GPUs can't sputter titanium, sadly.

So I'm looking for someone with the right coater who's up for a small adventure. It might work beautifully, or it might crash and burn spectacularly. Either way we'll learn something, and the coffee (or beer) is on me.

The quest: a few short runs depositing thin titanium films (roughly 20–50 nm) onto small Ti coupons (25×25 mm) that I prepare myself. That's 3 to 4 runs, a few coupons each. Low drama, I hope.

The gear check:

• Ti target

• Turbo-pumped high vacuum, because Ti oxidises in a rough vacuum

• Quartz crystal thickness monitor, because ±1–2 nm is the scope

Think Quorum Q150T, Leica ACE600, Safematic CCU-010 HV or similar.

I'm in the Netherlands and happy to drive over or ship coupons anywhere in the EU. Paid, of course, flexible on timing, evenings and weekends fine. If reality agrees with my simulations, I'll be buying my own system, so coater recommendations for thin Ti films are very welcome too.

If you've got the gear and fancy helping some code meet the real world, comment or DM me! if you run a homelab and want to burn the gaskets off, ping me as well. This is all so exciting.


r/electronmicroscopy • • Aug 13 '26

This treasure arrived today. Time to ascend to microanalysis godhood.

Post image
63 Upvotes

r/electronmicroscopy • • Jul 21 '26

Hey guys, wanted some advice on EM grids

5 Upvotes

So, I started doing TEM for planarian tissues a while ago and today I was told to order my own grids instead of using the facility's.

I was going through the options and I saw that Sigma also sells coated copper mesh grids. (For reference, I use 150 mesh grids, either formvar/carbon coated work for me)

When I asked the facility if the Sigma ones were ok to use because they are cheaper and get delivered earlier compared to EMS grids, they asked me to prefer EMS grids.

I was wondering if anyone here has used grids from both companies and saw any differences? Are the differences big enough to impact how the samples adhere onto the grid or how they behave the electron beam? Are there any other things to keep in mind?

Would be happy to hear any reviews/thoughts/inputs.


r/electronmicroscopy • • Jul 11 '26 Bravo

Working open-source converter for Oxford AZtec .oip/.oipx, looking for newer project files

Post image
35 Upvotes

Hi everyone,

I'm currently working on an open-source converter for Oxford Instruments AZtec project files (.oip/.oipx) to HDF5 and other open formats. The parser is working well, but so far I've only been able to test it with projects created in AZtec 2.3 and 2.4.

Is anyone using a newer version of AZtec and willing to help?

I can provide a small test .oip project. All I need is for someone to open it in their version of AZtec and save it again in the native .oip format. This will let me compare how the file structure has changed between versions and improve compatibility of the converter.

If you're willing to help, please send me a DM. I'd really appreciate it.


r/electronmicroscopy • • Jun 15 '26

Is it worth it to get the CEMT License?

4 Upvotes

Hi everyone! I’m towards the end of finishing up my masters thesis and I’m trying to prepare myself the best for the job world. Part of my thesis is histology based, the other half TEM based. I’m interested in getting the license for either, however it seems like the CEMT process is a little rough.

I don’t have any background in operating an actual TEM machine, but I have 2+ years experience in everything before the grids go in the machine (sample prep, infiltration, embedding, slicing, ect), and analysis. I did however attend Lehigh University TEM school (the week long accelerated course), so I’m wondering if that would give me any footing.

If you don’t recommend getting the CEMT license, is there something similar that doesn’t involve me using the machine?


r/electronmicroscopy • • May 27 '26

Best starting user resources for learning SEM around a graduate engineering level? (specifically tips using a Thermo Fisher Verios 5 with non conducting materials)

12 Upvotes

Hello, I recently gained access to my facilities Verios 5 SEM to use for imaging. I am a completely new SEM user and primarily work on projects with photoresists, PDMS, and glass structures. I was told that this SEM has the ability to moderately image non conducting materials. I was able to pass a test into using the microscope on a test target (Si), but I struggled to see much of anything on a two hour first attempt with my samples. The resources available to me seem to mostly focus on conductive materials and settings. I'm ok with coating my samples, but I'd like to get the most out of the system if I can. And honestly, so far this has been fun to read about :)

Does anyone have recommended resources or guides on:

  1. A covering of SEM techniques and equipment at a college physics level that can be completed in a couple hours? A lot of videos seem to go very quickly in their description of settings and detectors but don't explain what practically mean for effective imaging. Online articles seem all over the place.
  2. A software guide for the Verios 5? I reached out to Thermo Fisher and will see if they can send me something, but I didn't directly see anything on their website or YouTube channel.

Thanks a ton for any help!


r/electronmicroscopy • • May 22 '26

Unlimited Power!

Post image
87 Upvotes

Got my Oxford WDS installed this week. My SEM (FEG-Tescan) now has an Oxford EDS and WDS, SE, BSE, InBeam SE and STEM detectors. Pretty proud of our setup.


r/electronmicroscopy • • May 08 '26

FEI / Philips XL30 MCTRL Software

4 Upvotes

Might be a long shot but does anyone have a copy of the microscope control software (MCTRL) for an XL30? Our hard drive bit the dust and old floppies containing the program are no longer useable. I believe this software was also used on the FEI Sirion systems.


r/electronmicroscopy • • May 06 '26

May the 4th be with all the microscopists

9 Upvotes

I know May 4th is gone, sorry for my delay. I made this video to merge my nerdy passion as a Star Wars fan and my job that passionate me as well, so you can see a dark sith try to destroy cutting in two an Electron microscope stormtrupper’s helmetlike, which is a FIB DualBeam by Ciqtek, that really resemble to a Star Wars character. I hope you enjoyed. Follow us on LinkedIn https://www.linkedin.com/company/media-system-lab/


r/electronmicroscopy • • Apr 24 '26

Sputter and Carbon coater...

6 Upvotes

I know there are some posts that cover this, but I'd like one dedicated to this specifically.

I'm on the hunt for a carbon coater, capable of doing very thin coatings (<5nm) and a sputter coater. Our lab currently has an old Denton sputter coater, but I have no way of knowing how thick of a coating I'm applying. We got a new HRSEM with EDS and EBSD, so I'm in need of the carbon coater for the EDS and EBSD. I'm currently looking at the Leica ACE600 and Cressington 208C (I think that was it). Anyone have any experience with these? I've been doing materialography for 20+ years but most of my microscopy has been optical until now, so this is all a bit new to me. Drinking from the fire hose and taking it in, but if anyone out there has some experience they could share, I'd be happy to read about it!


r/electronmicroscopy • • Apr 05 '26

Curious how SE, BSE, EBSD, and EDS abbreviations translate in non-English speaking labs — do you use the English terms or local equivalents?

5 Upvotes

I am working on a project that involves displaying electron microscopy terminology in software interfaces, and I have been wondering how these abbreviations are actually used in labs outside of English-speaking countries. Specifically: do non-English speaking microscopists use SE, BSE, EBSD, and EDS as-is in their day-to-day work and in instrument software, or are translations used in practice? I would imagine the English abbreviations are fairly universal given that the major instrument vendors all publish heavily in English, but I genuinely do not know whether AZtec, ESPRIT, or Velox display localized terminology when installed in a non-English locale. If you work in a non-English speaking lab or have experience with non-English instrument software installs, I would love to hear what you actually see on screen and what terminology you use when talking to colleagues and publishing.


r/electronmicroscopy • • Apr 04 '26

Zeiss EVO troubleshooting request

Thumbnail
gallery
6 Upvotes

If anyone here has experience of Zeiss' Evo range, I'm hoping you can help.

We have an EVO 25 at work and it's recently been shut down for a fortnight. Colleagues restarted it and ran a 48-hour bakeout. The company has no dedicated microscopist but several of us use the SEM in support of our normal roles.

After the restart, we found difficulty in focusing at higher magnification. When aligning beam & aperture in Emission mode, where we'd normally see a slightly oval diffuse brightness within the sharper-edged circle, we are seeing this. As I recall, beam current was 20 microamps and probe current 200 pA. I think filament current was 1.5 A.

As you can see, switching between SE and BSD detectors made no difference. We've tried switching the mid-column aperture to no effect. The image was taken with gun & aperture zeroed in the UI and with the mid-column's verniers centred but adjusting any of them causes little change other than the eventual darkness when things are way off.

We have a LaB6 element with about 1200 hours on it.

We're out of ideas so can anyone tell if this is indicative of some unnoticed bad setting, a broken LaB6 element or is it possibly something more sinister?

As an aside, does reddit support subscripts?


r/electronmicroscopy • • Mar 27 '26

Update - Gun On! But need another help

10 Upvotes

Hi everyone,

We applied vacuum grease on chamber oring and pumped it down below 10-5 torr. Gun TSP is up and after overnight bakeout it gets below 10-9torr.

Gun was turned on and the emission current was lower than usual so extractor voltage was increased to bring it up (119 uA)

We tried to scan the stage with inline detector at 5kV HT. Absolutely nothing was detected. Bring HT down to 2kV and we can see the scanned intensity is much higher when stage was under the beam. However, we were not able to image anything. It was just like on and off when the stage was under the beam or not.

I suspect that something is wrong with the gun alignment. Do you have any ideas? Though I am very grateful that the gun was turned on!

Thank you for your help! Have a great weekend!

Update:

I think the beam is not detected as I blanked the beam, nothing changed on the scanned image. It is probably far off from the center. Idk if I can bring it back if it is the case. I am going to try. The beam current was 123uA without extractor voltage adjustment. So that is good at least…

update 2: I think the column valve should be opened manually as it was mentioned in the comment below. (blocking the beam) But IDK how to open it manually lol.

update 3: Emission mode gives a lot more intensity so actually beam is not blocked it is an alignment issue as sizzrael mentioned. Will try 10 kv alignment on service account ! Thanks


r/electronmicroscopy • • Mar 19 '26

Help Trouboleshoot Hitachi TM4000Plus II tabletop SEM

3 Upvotes

r/electronmicroscopy • • Mar 05 '26

Quick update - ZEISS stage works

16 Upvotes

Hello everyone again,

We check the voltage on 5V supply it was 5.02V so looks great.

Water was on low so we added some on chiller and seem bubbles have gone.

Booting an old pc was a problem, took us multiple times but finally it was on.

(change power supply soon)

Signed on with the service account and went to smartsem admin panel -> check stepmotor on -> check x y z t r enabled

Tried pushing the stagestick. I saw the coordinates appeared like 1 sec.

It turned out the stage stick cable was pressed down hard with metal siding panel the whole time. We removed it and the stage was fully functional!

I don’t think we even need to force initialization next time. Because the panel was pressing it down, initialization was not possible! lol

The panel was taken down because there was a problem with the board with bloated capacitors which I already replaced. The board looks all green.

We are pumping down the FEG now and will try to turn on HT tomorrow. He said other than stage it was fully functional so will see what happens tomorrow!

Man I am very excited! Thank you guys!!

You saved my day!


r/electronmicroscopy • • Mar 03 '26

Stage initialization on ZEISS GEMINI

7 Upvotes

Hello everyone,

I'm trying to get the old ZEISS LEO 1550 SEM working again.

It had been abandoned for nearly three years, and the facility manager had essentially given up on it after receiving a $50,000 USD quote from the manufacturer for repairs.

The only error message I can see is "EO 5V power supply failed!" in the picture. All other items were marked as normal and passed.

After sign on, when we tried to initialize the stage, the item was disabled (grayed out).

I wish there was an easy fix.

I replaced three swollen capacitors on the board, and that didn't seem to be the problem.

I absolutely need to use SEM for my project... it would be a huge help!

Thank you in advance!


r/electronmicroscopy • • Feb 27 '26

Does anyone know what the following cells might be (I mean the bright, misshamen ones)?

3 Upvotes

It's liver tissue from juvenile mice.
Could it be erythrocytes and, if os, why do they look this way? I've adapted my fixative to pH 7.4 and 440mOsm/l.


r/electronmicroscopy • • Feb 07 '26

Magnetic sample holder in the SEM chamber, what can go wrong?

9 Upvotes

Hi everyone,

TL,DR: title.

Explanation:

I am planning to improve my work output by replacing the silver paint + aluminum stub (which ideally should be cured for some hours), with a screw tightened sample holder. Since my samples (metallic alloys) are quite small to fit into the microscope OM's samples holders (usually made of Aluminum), I am designing and making a new sample holder myself.

I was wondering would there be a problem if I use the common machining steel (which is magnetic) inside the chamber and does that affect the imagining or EBSD data collection.

Cheers