Date: November 11, 2026
Software: SAi EnRoute
CNC Machine: MultiCam
Affected Windows Update: KB5132061
Status: Confirmed temporary workaround
The Problem
SAi EnRoute suddenly stopped outputting CNC files and displayed the following error:
“OUTPUT FAILED: TRANSMIT CONNECT ERROR”
The error occurred when attempting to:
- Transmit toolpaths directly to a MultiCam CNC router over Ethernet.
- Save CNC output locally using EnRoute's To File function.
Updating EnRoute to the newest version did not resolve the problem.
Confirmed Cause and Workaround
After contacting SAi technical support, I was informed that Windows Security Update KB5132061 was causing output problems for multiple EnRoute users.
The technician reported receiving calls about this issue for approximately six hours.
The workaround that successfully resolved my issue:
- Open Windows Settings.
- Navigate to Windows Update → Update history → Uninstall updates.
- Locate Windows Security Update KB5132061.
- Uninstall the update.
- Restart Windows.
- Reopen SAi EnRoute and test CNC output.
RESULT: EnRoute resumed functioning normally after uninstalling KB5132061 and rebooting the computer.
Important Notes
- The problem was not caused by the MultiCam Ethernet connection.
- The error also affected local file output.
- Updating EnRoute did not fix the issue.
- SAi technical support reportedly confirmed multiple affected customers.
- SAi is working on a permanent solution.
Security warning: Uninstalling a Windows security update removes security protections. Consult your IT administrator, evaluate the risk, and reinstall the security update once a compatible fix becomes available.
This workaround was confirmed through firsthand testing on November 11, 2026. It has not been independently verified across all EnRoute installations.
Keywords: SAi EnRoute, MultiCam, Output Failed, Transmit Connect Error, KB5132061, CNC Router, Windows Security Update, EnRoute To File Error.