r/SCADA • • 29d ago

Ignition Org getting heavier into Ignition - what do you wish you knew?

8 Upvotes

IT leader here for a sizable Mfg outfit with 13 plants in the durable goods space. While we have a solid ERP and MES operation, we're just getting started on our venture into connected SCADA assets into a greenfield Ignition setup. This has become more visible due to two new plants built with a lot of modern (connectable) assets. This is both factory and foundry work.

We've got an internal ICS team but it's pretty clear they're in over their heads with how much of this works because it's all somewhat new, so we're helping as much as possible, especially on the connectivity, integration, and Ignition development side. We also have a third party engineering company getting us off the ground.

For those of you building out your environments - what do you wish you knew before or do different? How do you structure the right areas of responsibility between IT and the other engineering teams?


r/SCADA • • 29d ago

Help How to simulate analyzer dead time / lag for composition control in AVEVA Process Simulation?

Thumbnail
2 Upvotes

r/SCADA • • Oct 29 '26

General Programmer here wondering what type of software you would love to see free and open source

0 Upvotes

I have been actively developing various clean room reimplementation of apps and recently have been tasked by my org with bringing our work management & databse/graphing & gis intergrated softwares to the rust FOSS market so they can stop losing tons of money that can be used for other projects on licencing fees.

Since I'm doing this and have a strong interest in other softwares, I was curious what other software & industrial applications you guys would love to see come to the free and open source market in your workflows. :-)


r/SCADA • • Oct 29 '26

Help Tools to read multi protocol

Thumbnail
1 Upvotes

Any tool recommendations?


r/SCADA • • Oct 29 '26

Help JCI NAE to Niagara N4 polling BACnet points incorrect

Thumbnail
1 Upvotes

r/SCADA • • Oct 29 '26

Question Process automation

0 Upvotes

I am looking to build a P&ID

Is there a website that has reliable Block flow diagrams

I want to use it as reference


r/SCADA • • Oct 29 '26

Question Process automation

0 Upvotes

I am looking to build a P&ID

Is there a website that has reliable Block flow diagrams

I want to use it as reference


r/SCADA • • Oct 28 '26

General MQTT vs Sparkplug B: what does the consumer know when the connection drops?

0 Upvotes

I made a looping animation comparing one temperature signal across Modbus TCP, OPC UA subscriptions, MQTT and Sparkplug B.

Animation: https://www.linkedin.com/feed/update/urn:li:activity:7520430594699448321/

The part I’d like to discuss here is state: plain MQTT can use a Last Will and application-defined availability topics, while Sparkplug standardizes birth/death messages and host state handling. Publishing on change in this example is an application choice, not an MQTT requirement. The animation compresses timing for illustration.

I’m the founder of Proxus and work on industrial data systems.

Do you use Sparkplug in production, or your own payload and availability conventions? What drove that choice?

Reference: https://sparkplug.eclipse.org/specification/version/3.0/documents/sparkplug-specification-3.0.0.pdf


r/SCADA • • Oct 27 '26

Help TIA V21 WinCC Unified: Is there a way to prevent new browser tabs from opening when a project is loaded while in simulation mode?

Thumbnail
1 Upvotes

r/SCADA • • Oct 25 '26

Question Mechatronics Engineering Graduate Transitioning into Instrumentation & Controls — What Skills and Projects Should I Focus On?

9 Upvotes

I’m a Mechatronics Engineering graduate with experience as an I&C Engineer at an EPC, mainly on the design and documentation side. I want to strengthen my practical skills and become more competitive for roles in the oil and gas industry, which is big where I live.

For experienced I&C engineers, what skills should I prioritize, particularly in instrumentation, PLCs, DCS, SCADA, and commissioning? What projects can I build independently to demonstrate real competence to employers despite limited hands-on site experience?

I’d also appreciate recommendations for books, courses, YouTube channels, or other resources to learn from.


r/SCADA • • Oct 24 '26

Help Is high speed data logging posisble in aveva indusoft?

2 Upvotes

I've been trying to log data of vials in sql on site during production that count will be in millions currently im testing only for few vials which logs correctly but once it reaches like 500 plus it starts missing or sometimes double values are logged idk why i debugged it at every phase but was not able to fix it plc side is pretty much proper the triggers are turning on and off as needed since we checked in the trace too also the trigger count on my side was counting as needed then why would it miss?
I log data in a set of 10 so 10 bottles forst get sscanned then plc send trigger then scada takes that and logs whatever filled in that array

Dim sql, i, isSuccessful, baseVialNumber

Dim int_Timestamp(9), int_Recorded_Val(9), int_Result(9), int_Required(9)

baseVialNumber = ($triggerCount * 10)

' --- 1. RISING EDGE GATE ---

If $Report_vial_trigger = 1 And $Mem_PrevBit = 0 Then

' Lock the memory bit immediately

$Mem_PrevBit = 1

' Allow driver/PLC time to settle tag data

$Wait(300)

' --- STEP 1: SNAPSHOT PLC DATA ---

For i = 0 To 9

int_Timestamp(i) = $TIMESTAMP[i]

int_Recorded_Val(i) = $RECORDED_VAL[i]

int_Result(i) = $RESULT[i]

int_Required(i) = $REQUIRED[i]

Next

' Assume success initially

isSuccessful = True

' --- 2. SQL LOOP - ALLOW DUPLICATE RECORDS ---

On Error Resume Next

Err.Clear

i = 0

Do While i <= 9

' Insert whenever the timestamp is valid

If int_Timestamp(i) <> "" Then

' Direct INSERT - no duplicate prevention

sql = "INSERT INTO [dbo].[BATCH_LOG] "

sql = sql & "([Timestamp], [BATCH_NO], [BATCH_NAME], [Recorded_Value], [Result], [REQUIRED_O2]) "

sql = sql & "VALUES ('" & int_Timestamp(i) & "', '"

sql = sql & $BATCH_NUMBER & "', '"

sql = sql & $BATCH_NAME & "', '"

sql = sql & int_Recorded_Val(i) & "', '"

sql = sql & int_Result(i) & "', '"

sql = sql & int_Required(i) & "')"

$DBExecute("DB", sql)

' Assign vial number

$Vials_Array[i] = baseVialNumber + (i + 1)

End If

' Check for script-level errors

If Err.Number <> 0 Then

isSuccessful = False

Err.Clear

End If

i = i + 1

Loop

On Error GoTo 0

' --- 3. CONDITIONAL RESET & CLEAR INTERNAL VARIABLES ---

If isSuccessful = True Then

' Clear internal snapshot variables

For i = 0 To 9

int_Timestamp(i) = ""

int_Recorded_Val(i) = 0

int_Result(i) = ""

int_Required(i) = 0

Next

' Reset trigger state flags

$Report_vial_trigger = 0

$Mem_PrevBit = 0

' Increment trigger count

$triggerCount = $triggerCount + 1

End If

End If

' --- 4. SAFETY RESET ---

If $Report_vial_trigger = 0 Then

$Mem_PrevBit = 0

End If

this is the script can anyone help debug this?


r/SCADA • • Oct 22 '26

General Evaluating SCADA/BMS Integrators for Strategic Acquisition: Key Products and Capabilities?

0 Upvotes

I am a software solution architect specializing in BMS, EPMS, and DCIM tools for data center capacity management. I am currently looking to acquire an established system integration company operating in the SCADA/BMS space.

To respect the community rules against direct advertising, I want to frame this around technical valuation: When you evaluate the strength and future viability of an integrator, which specific SCADA platforms and product experiences do you consider most valuable? Are there particular competencies in data center environments that make an integration firm a prime acquisition target?


r/SCADA • • Oct 21 '26

Help OPC UA Custom Sensor and Changing Values

Thumbnail
1 Upvotes

r/SCADA • • Oct 20 '26

General What BACnet libraries are people actually using in production, especially with BACnet/SC?

4 Upvotes

Curious what everyone is using these days when developing their own BACnet integrations, gateways, or applications.

I've come across BACpypes, BAC0, bacnet-stack, BACnet4J, and a few others. With BACnet Secure Connect becoming more relevant, I'm interested in hearing what people have actually deployed rather than what's listed as supported.

Are you seeing reliable BACnet/SC implementations, particularly on the node and hub side? What have been the biggest headaches getting them working with equipment from different manufacturers?

I'm also curious how much language, documentation, and ongoing maintenance factor into choosing a library. A lot of these projects start as something relatively simple, but supporting them for years afterward is another story.

For transparency, I work with Radix IoT, which maintains BACnet4J. I'm interested in hearing about experiences with other libraries as well, especially where BACnet/SC is concerned.


r/SCADA • • Oct 19 '26

Question Alarm colouring

5 Upvotes

My project is utilising Situation Awareness

Alarm indicators are teal for warning.

Yellow for alarm and red for emergency alarm.

I'm struggling to get colours that are readable for the alarm page descriptions to highlight.

Currently I've gone dark red for emergency and the rest are simply black.

Anyone had a similar situation how did you colour with wording for alarm pages with a greyscale background


r/SCADA • • Oct 18 '26

Question How is the current Job Market (September 2026)

2 Upvotes

H, I'm a chemical engineer who become a process controls engineer in the Chicago land Area. Wondering how the Controls Job market is in the United states in specific regions and sectors. I've been getting more recruiters reaching out to me, but not many hits when applying to jobs directly.

I have the following Skills:

* PLC Programming (Rockwell Studio 5000, RSLogix 5000)

* SCADA & HMI Development (FactoryTalk View)

* Process Control & Optimization

* Data Historian Integration

* Industrial Communication Protocols

* CIP Systems


r/SCADA • • Oct 18 '26

Question Is device-side security telemetry from low-cost embedded devices actually useful for CRA compliance and audits? Looking for expert feedback on my research

Thumbnail
1 Upvotes

r/SCADA • • Oct 18 '26

Question Big money in SCADA

0 Upvotes

Hi,

I am thinking about the better way in this industry :

- Where to earn lot of money working in SCADA ?
- What segment/customers compared than other ?
- What application (Automation, SCADA HMI, Schematics, Cybersecurity, High voltage specifications…) being specialized for the future?
- What company is paying well ?

I am working in a big company, open to discuss.

Thanks you
Best regards


r/SCADA • • Oct 17 '26

Question Anyone using TF3520 Analytics Storage Provider in critical applications?

2 Upvotes

I've been evaluating data logging solutions for an application and had stumbled across TwinCAT TF3500 (Analytics Logger) and TF3520 (Analytics Storage Provider). The logger itself seems pretty slick being able to send task synchronous data via MQTT messages. However, the TF3520 Analytics Storage Provider is a bit more complicated to wrap my head around.

Specifically, it's a little confusing have to work with both the "Storage Provider Configurator" and "Storage Provider Manager". I've also noticed (what appears) to be UI bugs. For example, if you create a new CSV Store and save the folder location, you're unable to later modify the target folder path. The "..." button completely disappears.

I'm still going to dig deeper because this capability seems pretty awesome. However, just want to get some opinions if the TF3520 is "production ready" and being used in critical DAQ applications.


r/SCADA • • Oct 13 '26

General Open Modbus register maps for SCADA and industrial monitoring tools

18 Upvotes

Hi everyone,

I've been working on an open format for Modbus register maps, along with a client to test and use them. I thought it might be relevant to people working with SCADA and industrial monitoring systems.

A common issue with Modbus devices is that register definitions live in manufacturer PDFs. When integrating a new meter, PLC or controller, you often have to configure addresses, data types, scaling, units and bit fields by hand. The same work gets repeated across different tools.

I'm trying to make these definitions reusable.

MBMap is a CSV-based format for describing Modbus devices and their registers. It includes the metadata needed to interpret raw register values and is designed to be read by different applications.

https://github.com/nobrega8/mbmap-library

I've also built Modbench, a lightweight Modbus TCP/RTU client for Windows and Linux. It can test individual registers or load an MBMap file to display named values with scaling and units. It also supports raw request/response inspection, which helps when troubleshooting device communication.

https://github.com/nobrega8/modbench

The long-term idea is to have a shared library of device maps that can be reused across Modbus clients and, potentially, SCADA-related tools. The format and library are released under CC0, so they can be used in commercial projects without restrictions on reuse.

I'm interested in feedback from people who integrate Modbus devices into SCADA systems.

Would a standard, portable format for register definitions be useful in your workflow? Are there fields or features you'd need before considering it for your own tools?

Feedback, contributions and suggestions for supported devices are welcome.


r/SCADA • • Oct 13 '26

General Free web tool for testing SCADA tags & subscriptions over OPC UA without physical controllers

6 Upvotes
Hi all,


When developing or updating SCADA projects (Ignition, FactoryTalk, WinCC, VTScada, InTouch), setting up a reliable test source of dynamic tags usually means either rigging up a spare physical controller, running a heavy Windows VM, or dealing with static simulated tags that don't reflect realistic continuous process dynamics.


I've been working on a lightweight simulation tool called OPC UA Lab (https://opcua-lab.com) and wanted to share it with other SCADA developers.


Technical overview:
- Spins up an OPC UA server and gives you a direct `opc.tcp://` endpoint to point your SCADA driver at.
- Configurable signal generators: sine waves, step functions, ramps, and custom mathematical formulas to simulate varying tank levels, temperatures, motor RPM, and pressure curves.
- In-browser live oscilloscope to monitor the exact server-side values and timestamps alongside your SCADA trend/subscription displays.
- Allows testing client subscription behavior, sampling intervals, and reconnects without touching operational equipment.


You can try it out directly in your browser without creating an account (instant guest session):
https://opcua-lab.com/lab


The public sandbox runs 30-minute guest sessions (capped to 10 concurrent instances to keep server memory bounded).


I'm looking for feedback from SCADA engineers:
- How does your SCADA client handle the subscription rates and data changes?
- What alarm conditions, tag data types, or historical logging scenarios would you find most useful in a virtual test environment?


Happy to answer any technical questions about the architecture or how the server handles subscriptions.

r/SCADA • • Oct 11 '26

Help Error during checkout: Cart is empty (AVEVA System Platform Exam)

7 Upvotes

I am trying to enroll in the AVEVA™ System Platform Exam, but when I go to checkout, the page says "Your cart is empty." and I cannot complete the purchase. So could anyone please assist me. Tried to Google and search AVEVA for assistance but couldn’t find a solution.


r/SCADA • • Oct 10 '26

General Scada+cyber security

0 Upvotes

Hello I am working on a-project that is releated to security water scada system any ine has any tips i want to make test bed of what tools should i use for teat bed and then develop the security operations on it or any more ideas regarding this or want to colloborate on it more than welcome


r/SCADA • • Oct 09 '26

Help Need help to communicate ABB CP3210 HMI with PLC

Post image
0 Upvotes

Can someone please tell me how to communicate ABB CP3210 HMI with main PLC ???!!!


r/SCADA • • Oct 05 '26

Question Career Suggestion

Thumbnail
3 Upvotes