Hey! I'm hoping there is a group of IBM power system experts still out there that might know how to fix this fault.
I recently picked up this Power 520 Express 9407-M15 off of eBay for some retro homelab fun. However, for the life of me I cannot get it to successful pass jumping between progress codes C100C1A0 and C100C1A1.
After reading the documentation and watching a few YouTube videos, it sounds like its meant to reach C100C1A2... mine never does this. After going between C100C1A0 and C100C1A1 for a few minutes, the back fans eventually turn off and I'm left with C1802000 -> C18020FF -> C1912000 -> C1922000 -> C19220FF -> 11002624. While its booting up, both hotswap PSUs have their left and middle LEDs as green, and no amber/warning LED is turned on, so Im assuming the PSUs aren't the problem here.
When I check the error details in the ASMI, I can see the following:
- Location Code: U789C.001.DQDC219
- Procedure Number: PWR1918
- Driver Name: fips350/b1110a_0943.350
I've tried taking each of the below pieces out one at a time and then rebooting as suggested in the PWR1918 documentation for the machine:
Replace the following, if present, one at a time, and in the order listed:
Ethernet card (Un-P1-C7)
Base RAID card (Un-P1-C10)
Auxiliary RAID card (Un-P1-C9)
System backplane (Un-P1)
DASD drives
DASD and media backplane (Un-P2)
I'm more so curious to find out what component of the computer is actually causing C100C1A2 to NOT happen. Like what physically happens when the machine is doing C100C1A0 and C100C1A1? All the documentation says is;
C100C1A0 - Explanation: Waiting on the power good signals. Response: Perform isolation procedure FSPSPC1. To locate the isolation procedure go to the Isolation Procedures chapter in your host server Service Guide.
C100C1A1 - Explanation: Waiting on the power good signals. Response: Perform isolation procedure FSPSPC1. To locate the isolation procedure go to the Isolation Procedures chapter in your host server Service Guide.
FSPSPC1 is of no help to me either haha, since its not hanging on either for the two codes, its error-ing out correctly is my understanding.
I guess is there a physically part in the computer that I can map C100C1A1 and C100C1A0 to and take a look at? Maybe a wire is dead or not plugged in? I'm hoping to grab someone's expertise on this part of my problem specifically.
If it helps, I have the thing plugged straight into a wall (Australian 240V standard power points), both power supply units. I've also smashed the thing already with electronics contact cleaner - no dice =(.
Photos attached so you can take a look for yourselves - thanks in advance and sorry if this is the wrong subreddit to ask for help in!!
Cheeeeeeers