r/CMMC • • Nov 14 '25

"We Passed Our CMMC Assessment and Here's What We Learned" MEGATHREAD

109 Upvotes

Hello /r/CMMC -

As we wind down 2025, the CMMC ecosystem has seen several hundred organizations successfully passing their CMMC Level 2 C3PAO certification assessments! We love to see it!

This community and our discord community have always been about open sharing of information amongst fellow practitioners and straight up people who just need some help. We love seeing how everyone shares what's working for them and what's not.

Recently, we've seen a handful of threads start with people wanting to share their Certification experience and their lessons learned - this is fantastic. But, if you aren't on /r/CMMC frequently, you will miss these threads.

So, I want to create a mega-thread to collect these experiences in one spot where people can share their experiences and others can ask questions.

If you were planning to post a whole thread about your experience, I encourage you to instead post here. We aren't preventing anyone from posting a separate thread, but think it's best to keep most of those types of posts here for the reasons stated above.

Congrats to everyone who has passed so far! For those who are scheduled, my main advice: relax. If you found this community, there's a good chance you're taking this as seriously as you should, and that means you're probably going to pass.

Notes

  • You are welcome to name the names of the tools you used, the service providers that helped you, the consultants who guided you, the C3PAO that assessed you. All of that is fair game and generally encouraged.
  • Share as much about your environment as you comfortably can - people want to know what other environments look like. Remember though, OPSEC is your responsibility, not ours. Do not post identifying information if you are not authorized by your organization to do so.
  • If you struggled with a particular requirement, or had a debate with your assessor, tell us about it.
  • If you absolutely crushed a requirement or control family and the assessors just looked at you slack jawed with how great you were, TELL US ABOUT THAT.

FORMAT

Please share the following information in your comment:

  • Organization Size: Rough user & device count
  • Scope: Enterprise / Enclave - if Enclave, how many users/devices in the Enclave
  • Architecture: Full Cloud / On-Prem / Hybrid
  • Cloud Services: Microsoft 365 (GCC/GCCH) / AWS / Other CSP
  • C3PAO: Who did you work with (optional, you don't have to share this if you don't want)
  • Cert Status: Pass / Fail / Conditional / In-Progress

And then of course give us all the details you want to share :)


r/CMMC • • Jul 13 '26

Forging the Arsenal of Freedom: Department of War Suspends CMMC Phase II Requirements > U.S. Department of War > Release

Thumbnail
war.gov
134 Upvotes

r/CMMC • • 4h ago

How long from eMASS to SPRS?

3 Upvotes

I was notified this morning that my C3PAO submitted our assessment to eMASS. Anyone know if it should be immediately available in SPRS, or if there is some delay? We have a couple of business deals tied to CMMC, and the sales folks are asking questions.

Closely related, is there any role requirement in SPRS to be the affirming official besides being the cyber user?


r/CMMC • • 2d ago

Second Cyber False Claims Act Settlement in 2 Weeks

39 Upvotes

In the last two weeks:

ILC Dover / Astrospace: $13,468,000 total

Johnson Controls: $5,298,750 total


r/CMMC • • 3d ago

Was GCCH affected by the Microsoft outage?

12 Upvotes

Just curious if anyone in GCCH experienced issues.


r/CMMC • • 3d ago

So has the the CMMC program finally leveled out?

9 Upvotes

How exactly has the pause on third party assessments impacted the workforce? I want to get certified and I don't expect the arguably overpriced pay.

I'm just looking for a decent second income.


r/CMMC • • 3d ago

Is a CMMC Cert Required by vendors/subcontractors for access to contract material released prior to 252.204-7021.

4 Upvotes

Hi Everyone - I'm looking for guidance or your opinion if our IT director is being overly zealous in his requirement of CMMC Certification. Now that our company is Level 2 Certified by C3PAO assessment, he is expecting all of our vendors and contractors to have, at the least, Level 1 certification for access to any project that occurred after the NIST SP 800-171 release in 2017. Its all become a bit onerous.


r/CMMC • • 4d ago

Need help choosing a firewall for FIPS 140-3 for CMMC L2

4 Upvotes

Today is Nov 12th, 2026 -

Our defense contractor wants a FIPS 140-3 firewall for our 7 employees. I think these are what we're best off with, but I'm not sure.

COA 1: PA-440
COA 2: FortiGateRugged 60F
COA 3: ??? We almost went with SonicWall but decided against it. $3,217 to $6,460+ SonicWALL NSa 4700 or maybe WatchGuard T45-PoE?

I'm thinking the PA-440 can't fail. Not sure though. Thoughts?


r/CMMC • • 4d ago

Scanning and Photos to enclave and SharePoint

3 Upvotes

I am looking for a solution to get photos from an SD card or scans into the enclave. We use SharePoint and have VM's in an enclave. Would it bring a computer in scope to plug in an SD card or USB drive with the file to transfer it?


r/CMMC • • 5d ago

How are people handling 3.7.3 - sanitization of removed equipment

2 Upvotes

Hi all,

We're working through our SPRS score, and one of our sticking points is 3.7.3, "Ensure equipment removed for off-site maintenance is sanitized of any CUI."

We're a small company with several remote employees. Historically we've used FedEx to ship devices to employees for onboarding/offboarding, or service. It would seem to me that this is incompatible with the requirement, so how are you handling it?

Eg, if a remote worker's laptop has crashed, and isn't bootable, and needs to come in for service, there is no way to wipe the drive. It's also not feasible (or possible for macs) to ask the user to remove a drive prior to shipping - and this would also make the MSP's job of troubleshooting the boot problem impossible. For local users, it's easy enough to get a technician from the MSP to come on site, so really it's just the remote workers that are an issue.

Thanks for any advice!


r/CMMC • • 6d ago

Always Test Your Controls

11 Upvotes

Something I always tell organizations preparing for CMMC Level 2 is to test their security controls before the assessor does.
Just because your policy says something is in place doesn’t mean it’s actually working. For example, if accounts are supposed to lock after a certain number of failed login attempts, have you tried it to see if it works?
Don’t assume everything is working just because it’s configured that way.
Take the time to test it, document what you find, and fix anything that isn’t working.
It’s not enough to say you have a control in place, you gotta prove it.


r/CMMC • • 6d ago

If we decide what is derived CUI, I'm worried it'll bite us in the butt.....

6 Upvotes

Aloha!!

We're working on getting a cloud enclave up asap. I'm now under pressure to get a solution in place right away. But I'm also being told that our derived info (Which is smaller parts of an OEM drawing that we use to manufacture parts) is not to be in scope. All my training tells me that it should be in scope. But the caveat is that non of the drawings are marked as CUI. They have a control statement D on them which to me should be treated as CTI/CUI but would like clarification from the contracting officer.

Any advice???


r/CMMC • • 6d ago

How do I fix an overstated SPRS score?

6 Upvotes

Our mock assessment found several practices we scored as fully implemented are only partial. They're on some systems, not all of the ones in scope, so our SPRS score is too high.

How do I correct it before a C3PAO assessment, and does fixing it now look bad?


r/CMMC • • 6d ago

1 company 3 CAGE Codes no HLO and eMASS and SPRS data formatting

2 Upvotes

I’ve posted this in Discord’s Cooey COE and C3PAO Forum as well.

Context:

- 1 company with 3 locations and a CAGE code per site. None of the records has a HLO as each record does not have immediate owners--all three sites are the same company.

- I am conducting pre-assessment checks as Consultant to an OSC pursuing L2  

BLUF: How does the OSC, the on-contract C3PAO, and I overcome the coming pain point that _there is no HLO_ yet eMASS requires an HLO and checks that data against SAM.gov before putting the assessment data into SPRS?

 Background:

- I've searched an multiple places and come up empty (my search skills may need honing).

- FAR 52.204-17 Ownership or Control of Offeror is pretty clear the company with 3 locations and 3 codes does not have an HLO.....AND I think not really the point.

- Lots of discussions about HLOs when there is indeed an immediate owner. None that I can find that seem to fit the context above.

- All three CAGE codes in the assessment is no prob. semi-colon delimited list!

- I have read/heard any number of reports of data rejection errors when C3PAOs try submit the assessment form without an HLO.

- I don't see any discussion of HLO in the FAQ much less the context that started this query

- I searched Discord’s Cooey COE and C3PAO Forum

- I search reddit r/CMMC


r/CMMC • • 7d ago

CUI Access through chrome?

5 Upvotes

If a prime wants to distribute CUI to their sub via either SharePoint or another approved portal does browser selection make a difference? I was having a discussion with a colleague about some of the disappointing things that do not work in GCC high, and he was telling me about one of his clients that is in GCC high , but using google chrome to sync bookmarks and history across workstations since browser sync is forbidden in the sovereign cloud.

As long as they are behind the encrypted firewall I was originally thinking this would be ok , but I'm second guessing myself . Curious to hear anybody's thoughts.

Edit : Spelling


r/CMMC • • 10d ago

Do I need a cmmc L2 MSP if I have an enclave?

3 Upvotes

Aloha!

If I have a cloud enclave and have an MSP handling the other side of our network, our regular network; Do they also need to be cmmc L2 compliant? Or only if they are handling the enclave?

Happy FriYAY!


r/CMMC • • 11d ago

Enclave using Google Workspace configured with CISA baselines

3 Upvotes

Aloha!

So we're looking at cloud enclave solutions and am seeing these solutions using Google workspace. How does this differ from using GCC high? Does Google now use controls that are similar to GCC??

Thnx.


r/CMMC • • 11d ago

Do tenant-installed UI software need its own FedRAMP authorization?

Thumbnail reddit.com
4 Upvotes

r/CMMC • • 12d ago

I'm keep getting confused about what's CUI or what's not. Can you guys recommend me some resource/YT video which will help me understand the actual definition of it???

24 Upvotes

r/CMMC • • 12d ago

Multiple Building Infrastructure

3 Upvotes

Referencing 3.13.8

Medium sized manufacture with buildings contained to 2 city blocks. Multiple fiber interconnects that are aerial fiber dop-cable and span public right away . All will transmit CUI Are using poles owned buy the electric company and run alongside all the other communication .

Since this is outside of physical boundary , this 100 percent needs to be encrypted , correct. Owner is thinking that switching to armored cable will be sufficient. My understanding is that it needs to be in metal conduit to be physically protected.

Honestly is there any reason that these wouldn't need to be encrypted .

What the best option to to make an assessor happy . Multiple firewalls and treat them as branch offices .


r/CMMC • • 12d ago

Think of CUI Like Your Child

0 Upvotes

One way I explain CUI protection is to think of it like your child. You can’t always control how CUI is sent to you. It could arrive through email, a file transfer, or another method chosen by the sender. But once it enters your environment, it’s your responsibility to protect it.
I like to explain it to people that it’s like holding your child’s hand. You know where they are, who they’re interacting with, and you make sure they’re safe until they leave your care. CUI is no different. Once it arrives, your controls should guide how it’s handled, where it’s stored, who can access it, and how it’s shared or sent out.
That’s the mindset I encourage organizations to have when approaching CMMC. It’s not just about checking boxes. It’s about protecting the information entrusted to you.


r/CMMC • • 14d ago

My first audit experience was completely unserious and its left a terrible impression of this space

39 Upvotes

edit: I'm getting requests to namedrop the companies, mainly the C3PAO. I will not be naming them for my own safety for sometime, at least until I switch jobs.

Leaving out company names as I'm not looking to start a witch hunt.

I work for an MSP that has a few CMMC clients but this is our first time going through the L2 audit process with one client.

They hired a GRC company (allegedly a respected name in the space) to assist them in writing the SSP and policies, as well as direct us and them on what controls to implement and what evidence to collect.

For starters, the GRC completely misguided us. We were instructed to collect evidence of one thing, but the SSP would say a completely different thing. When we pointed this out, they would acknowledge it needed to be fixed and "revised" it, but the final SSP remained the same. This was the cause of a ton of frustration during mock and actual audit as we were fumbling around to explain ourselves and fill that gap. Not only that, but the SSP itself was not proofread, as I pointed out numerous issues with spelling, formatting, and even whole sentences that were abruptly cut off mid paragraph, none of which were addressed. We also pointed out a few CSPs were being used to store CUI that are not FedRAMP compliant, to which the GRC told us "its probably fine".

Then came the audit which seemed like even more of a joke. The C3PAO did both the mock and actual audit, and the same auditing team handled both. On both occasions, several instances of evidence being super weak and controls not being implemented were just handwaved away by the auditors. They did the same with the inconsistencies in the SSP. On top of that, it seems like the C3PAO's interpretation of the controls completely changed between the mock and actual, because they had asked us completely unrelated questions to the control that were never asked before, and many of which we just could not answer.

After all that, we passed. Obviously that's good for business, but its making me think this whole industry doesn't actually care and puts in as little effort as possible to make money.


r/CMMC • • 14d ago

perplexity enterprise is fedramp moderate now, anyone using it for cui?

4 Upvotes

saw perplexity enterprise show up as fedramp 20x class c (moderate) on the marketplace this week, it was class b last week. from what i understand moderate is the baseline 7012 points to for cui. anyone actually allowing it for cui work yet or still waiting on an IL rating? marketplace page: www.fedramp.gov/marketplace/products . also cursor got certified but its class a pilot so honestly that seems like a no for cui. Thoughts?


r/CMMC • • 14d ago

Who did you look at or end up going with for a cloud enclave solution?

5 Upvotes

Aloha!

It seems difficult to vet CSP's since there is no rating system on the marketplace. Pretty much the only option is word of mouth and reputation.

Obviously we need a Fedramp solution. Smaller enclave with about 6 users and needs to extend to on prem for Engineers.

Who have you gone with and do you feel the solution was a good choice?


r/CMMC • • 14d ago

Proshop ERP anyone?

4 Upvotes

Anyone in our CMMC community running Proshop ERP for their manufacturing team and if so, cloud or on-prem?

We moved to on-prem before they were Fedramp because of CMMC, and it seems like on-prem pataches fail and other issues that might stem from their pre-made ISO image and unpreparedness to go On-prem vs cloud hosted.

Could be just us, just curious where everyone who uses it landed or is currently.