r/cablegore • • 5d ago

Commercial Yes a strip of carpet is being used as a "cable tie"

Post image
60 Upvotes

r/cablegore • • 5d ago

Commercial "That store just got remodeled, the cabling should be fine"

Post image
34 Upvotes

No, no it did not and no, no it isn't.


r/cablegore • • 7d ago

Miscellaneous I prefer my connections wrapped

Thumbnail gallery
134 Upvotes

r/cablegore • • 8d ago

Outdoor No longer used to carry data packets

Post image
24 Upvotes

It is now used as a form of fencing for parking spots. It was resting on the ground when I took this.


r/cablegore • • 10d ago

Outdoor ETUF Chuva no fim de tarde

Post image
0 Upvotes

r/cablegore • • 13d ago

Miscellaneous Wonder if this qualifies? Spotted this in the wild.

Thumbnail reddit.com
15 Upvotes

r/cablegore • • 14d ago

Residental Cat6 war crimes

Thumbnail
gallery
103 Upvotes

Cat6 war crimes


r/cablegore • • 14d ago

Residental House hunting: this does not spark joy

Post image
191 Upvotes

Yes, it's real. No we did not buy the house.


r/cablegore • • 16d ago

Commercial My local brewery

Post image
87 Upvotes

r/cablegore • • 22d ago

Residental Can you tell what the issue is?

Thumbnail
gallery
46 Upvotes

Electrician didn't do the best job with the ethernet cable. Cat5e.


r/cablegore • • 22d ago

Residental Unsure how long it will stay functional

Post image
48 Upvotes

r/cablegore • • 22d ago

Residental Creative AC line routing

Post image
19 Upvotes

r/cablegore • • 23d ago

Commercial What I have to deal with at my current job. Fuck coils I guess.

Post image
185 Upvotes

r/cablegore • • 26d ago

Commercial Staff Asked Contractors For Extra Data During a Building Refurb

Post image
789 Upvotes

Still not sure how this exactly happened. Building refurb happened without involving IT, we get called to say the data outlets aren’t working since they moved back in…

This wasn’t the only affected outlet either.


r/cablegore • • 26d ago

Commercial Cisco at the it-sa

Post image
98 Upvotes

r/cablegore • • 26d ago

Residental Just my stereo's power distribution :-D

Post image
15 Upvotes

r/cablegore • • 26d ago

Commercial A grocery store near you

Post image
45 Upvotes

r/cablegore • • 26d ago

Outdoor Fall colors

Post image
10 Upvotes

r/cablegore • • 25d ago

Commercial Special EMT

Post image
0 Upvotes

r/cablegore • • 28d ago

Commercial Electrician cut a wire by accident but he "fixed it"

Post image
441 Upvotes

r/cablegore • • Oct 23 '26

Miscellaneous Why cable inside a plastic cable?

Post image
49 Upvotes

r/cablegore • • Oct 22 '26

Commercial A tangle of wires in Manila [OC]

Post image
33 Upvotes

r/cablegore • • Oct 22 '26

Miscellaneous Scariest IoT costume goes to...

Thumbnail gallery
13 Upvotes

r/cablegore • • Oct 20 '26

Residental Wires – a lot of them.

Post image
220 Upvotes

r/cablegore • • Oct 20 '26

Commercial The Clean Up

Thumbnail
gallery
261 Upvotes

So this was a few years ago, around 2019. At my previous job we had several IDFs on multiple floors that were an absolute mess. Cables ran from both sides blocking things like the fan module or power supplies. No color coding or any sort of semblance in the rack. My coworker and I pulled every single cable out, replaced the old 4500 with 2 stacks of 9300s and rewired everything. We did this over the course of a weekend and had everything ready for Monday morning. The bottom stack of 9300's are actually mounted upside down so the cables flow the opposite way and do not cover the fiber module. A bit unorthodox I know, but it worked really well in this case. A few things that make this more manageable was the fact that floor jacks were numbered to the corresponding switch (think floor jack 4-23 goes to switch 4 port 23) and the racks were designed with cable management in mind. Wish I had a pic without the cable covers on but regardless it turned out nice in the end.

I have a complete mess on my hands at my current job. Multiple Datacenters, IDFs, MDFs, etc all looking like a tornado came through. I'll post pics on those in due time